GoControl GC-TBZ48 Z-Wave Plus Thermostat

This describes the Z-Wave device GoControl GC-TBZ48, manufactured by Linear Corp with the thing type UID of linear_gctbz48_00_000.

The device is in the category of HVAC, defining Air condition devices, Fans.

GoControl GC-TBZ48 product image

The GoControl GC-TBZ48 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

Overview

The Z-Wave Thermostat (GC-TBZ48) is a programmable, Z-Wave communications thermostat. It can be powered using 24VAC (if both “R”&”C”wires are available at the thermostat), or using four (4) AA batteries. Using Z-Wave technology, end users have the ability to use the 2GIG Go!Control panel to control the thermostat, configure programming settings, as well as to display current conditions in the home or office.

Inclusion Information

  1. Set your primary controller to Include, add or Install mode, to add the thermostat as a node on your network (see your controller’s user manual for detailed instructions).
  2. Press any button to take thermostat out of sleep mode.
  3. Press and hold FAN button for 5 seconds. SETUP will be displayed in the status display line.
  4. Scroll to “Z-Wave” using up/down buttons. Press SELECT.
  5. When prompted by your Z-Wave controller, Press the YES button in the Z-Wave Install screen.
  6. Press SELECT (mode button) to add thermostat to network.
  7. Display line should flash WAIT then SUCCESS if Z-Wave connection is made.
  8. If Z-Wave does not connect to controller, WAIT, then FAIL will flash in status display line.
  9. If thermostat fails to connect, repeat Steps three (3) through (7) to re-try connecting.

Exclusion Information

  1. Set your primary controller to Include, add or Install mode, to add the thermostat as a node on your network (see your controller’s user manual for detailed instructions).
  2. Press any button to take thermostat out of sleep mode.
  3. Press and hold FAN button for 5 seconds. SETUP will be displayed in the status display line.
  4. Scroll to “Z-Wave” using up/down buttons. Press SELECT.
  5. When prompted by your Z-Wave controller, Press the YES button in the Z-Wave Install screen.
  6. Press SELECT (mode button) to add thermostat to network.
  7. Display line should fl ash WAIT then SUCCESS if Z-Wave connection is made.
  8. If Z-Wave does not connect to controller, WAIT, then FAIL will flash in status display line. 

Channels

The following table summarises the channels available for the GoControl GC-TBZ48 -:

Channel Name Channel ID Channel Type Category Item Type
Scene Number scene_number scene_number Number
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number:Temperature
Thermostat mode thermostat_mode thermostat_mode Temperature Number
Operating State thermostat_state thermostat_state Temperature Number
Setpoint (cooling) thermostat_setpoint thermostat_setpoint Heating Number:Temperature
Setpoint (heating) thermostat_setpoint thermostat_setpoint Heating Number:Temperature
Thermostat fan mode thermostat_fanmode thermostat_fanmode
Thermostat fan state thermostat_fanstate thermostat_fanstate
Battery Level battery-level system.battery_level Battery Number
Clock Time Offset time_offset time_offset Time Number

Scene Number

Triggers when a scene button is pressed.

The scene_number channel is of type scene_number and supports the Number item.

Sensor (temperature)

Indicates the current temperature.

The sensor_temperature channel is of type sensor_temperature and supports the Number:Temperature item and is in the Temperature category.

Thermostat mode

Sets the thermostat.

The thermostat_mode channel is of type thermostat_mode and supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Off
1 Heat
2 Cool
3 Auto
4 Aux Heat
5 Resume
6 Fan Only
7 Furnace
8 Dry Air
9 Moist Air
10 Auto Changeover
11 Heat Economy
12 Cool Economy
13 Away

Operating State

Sets the thermostat operating state.

The thermostat_state channel is of type thermostat_state and supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Idle
1 Heating
2 Cooling
3 Fan Only
4 Pending Heat
5 Pending Cool
6 Vent / Economiser

Setpoint (cooling)

Sets the thermostat setpoint.

The thermostat_setpoint channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Setpoint (heating)

Sets the thermostat setpoint.

The thermostat_setpoint channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Thermostat fan mode

Channel type information on this channel is not found.

Thermostat fan state

Channel type information on this channel is not found.

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The system.battery-level channel is of type system.battery-level and supports the Number item and is in the Battery category. This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.

Clock Time Offset

Provides the current time difference for the devices time.

The time_offset channel is of type time_offset and supports the Number item and is in the Time category.

Device Configuration

The following table provides a summary of the 38 configuration parameters available in the GoControl GC-TBZ48. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 System Type System Type
2 Fan Type Fan Type
3 Change Over Type Change Over Type
4 2nd Stage Heat Enable 2nd Stage Heat Enable
5 Aux Heat Enable Aux Heat Enable
6 2nd Stage Cool Enable 2nd Stage Cool Enable
7 Temperature Unit Temperature Unit
8 Minimum Off Time Minimum Off Time
9 Minimum Run Time Minimum Run Time
10 Setpoint H/C Delta Setpoint H/C Delta
11 H Delta Stage 1 ON H Delta Stage 1 ON
12 H Delta Stage 1 OFF H Delta Stage 1 OFF
13 H Delta Stage 2 ON H Delta Stage 2 ON
14 H Delta Stage 2 OFF H Delta Stage 2 OFF
15 H Delta Aux ON H Delta Aux ON
16 H Delta Stage 3 OFF H Delta Stage 3 OFF
17 C Delta Stage 1 ON C Delta Stage 1 ON
18 C Delta Stage 1 OFF C Delta Stage 1 OFF
19 C Delta Stage 2 ON C Delta Stage 2 ON
20 C Delta Stage 2 OFF C Delta Stage 2 OFF
23 Lifeline Association Group Report To Send Lifeline Association Group Report To Send
24 Display Lock Display Lock
26 Backlight Timer Backlight Timer
33 Max Heat Setpoint Max Heat Setpoint
34 Min Cool Setpoint Min Cool Setpoint
38 Schedule Enable Schedule Enable
39 Run/Hold Mode Run/Hold Mode
40 Setback Mode Setback Mode
41 Un-Occupied HSP Un-Occupied HSP
42 Un-Occupied CSP Un-Occupied CSP
43 Remote Sensor 1 Node Number Remote Sensor 1 Node Number
46 Remote Sensor 1 Temperature Remote Sensor 1 Temperature
48 Internal Sensor Temp Offset Internal Sensor Temp Offset
49 R1 Sensor Temp Offset R1 Sensor Temp Offset
54 Heat Timer Heat Timer
55 Cool Timer Cool Timer
61 Fan Purge Heat Fan Purge Heat
62 Fan Purge Cool Fan Purge Cool

Parameter 1: System Type

System Type

The following option values may be configured -:

Value Description
0 Standard
1 Heat Pump

The manufacturer defined default value is 0 (Standard).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Fan Type

Fan Type

  • 0 = Gas (no fan w/Heat)
  • 1 = Electric (Fan w/Heat) The following option values may be configured -:
Value Description
0 Gas
1 Electric

The manufacturer defined default value is 0 (Gas).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Change Over Type

Change Over Type

The following option values may be configured -:

Value Description
0 w/Cool
1 w/Heat

The manufacturer defined default value is 0 (w/Cool).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: 2nd Stage Heat Enable

2nd Stage Heat Enable

The following option values may be configured -:

Value Description
0 Disabled
1 Enabled

The manufacturer defined default value is 0 (Disabled).

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Aux Heat Enable

Aux Heat Enable

The following option values may be configured -:

Value Description
0 Disabled
1 Enabled

The manufacturer defined default value is 0 (Disabled).

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 6: 2nd Stage Cool Enable

2nd Stage Cool Enable

The following option values may be configured -:

Value Description
0 Disabled
1 Enabled

The manufacturer defined default value is 0 (Disabled).

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Parameter 7: Temperature Unit

Temperature Unit

The following option values may be configured -:

Value Description
0 Celsius
1 Fahrenheit

The manufacturer defined default value is 1 (Fahrenheit).

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 8: Minimum Off Time

Minimum Off Time Sets the Minimum Off Time (MOT) delay before another heating/cooling cycle can begin Values in the range 5 to 9 may be set.

The manufacturer defined default value is 5.

This parameter has the configuration ID config_8_1 and is of type INTEGER.

Parameter 9: Minimum Run Time

Minimum Run Time Sets the Minimum Run Time (MRT) delay before a heating/cooling cycle can turn off Values in the range 3 to 9 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_9_1 and is of type INTEGER.

Parameter 10: Setpoint H/C Delta

Setpoint H/C Delta Sets the minimum separation between heating and cooling setpoints Values in the range 3 to 15 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_10_1 and is of type INTEGER.

Parameter 11: H Delta Stage 1 ON

H Delta Stage 1 ON Sets the delta from setpoint that stage 1 heating starts Values in the range 1 to 6 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_11_1 and is of type INTEGER.

Parameter 12: H Delta Stage 1 OFF

H Delta Stage 1 OFF Sets the delta from setpoint that stage 1 heating stops Values in the range 0 to 5 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_12_1 and is of type INTEGER.

Parameter 13: H Delta Stage 2 ON

H Delta Stage 2 ON Sets the delta from setpoint that stage 2 heating starts Values in the range 2 to 7 may be set.

The manufacturer defined default value is 2.

This parameter has the configuration ID config_13_1 and is of type INTEGER.

Parameter 14: H Delta Stage 2 OFF

H Delta Stage 2 OFF Sets the delta from setpoint that stage 2 heating stops Values in the range 0 to 6 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_14_1 and is of type INTEGER.

Parameter 15: H Delta Aux ON

H Delta Aux ON Sets the delta from setpoint that stage 3 heating starts Values in the range 3 to 8 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_15_1 and is of type INTEGER.

Parameter 16: H Delta Stage 3 OFF

H Delta Stage 3 OFF Sets the delta from setpoint that stage 3 heating stops Values in the range 0 to 7 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_16_1 and is of type INTEGER.

Parameter 17: C Delta Stage 1 ON

C Delta Stage 1 ON Sets the delta from setpoint that stage 1 cooling starts Values in the range 1 to 6 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_17_1 and is of type INTEGER.

Parameter 18: C Delta Stage 1 OFF

C Delta Stage 1 OFF Sets the delta from setpoint that stage 1 cooling stops Values in the range 0 to 5 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_18_1 and is of type INTEGER.

Parameter 19: C Delta Stage 2 ON

C Delta Stage 2 ON Sets the delta from setpoint that stage 2 cooling starts Values in the range 2 to 7 may be set.

The manufacturer defined default value is 2.

This parameter has the configuration ID config_19_1 and is of type INTEGER.

Parameter 20: C Delta Stage 2 OFF

C Delta Stage 2 OFF Sets the delta from setpoint that stage 2 cooling stops Values in the range 0 to 6 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_20_1 and is of type INTEGER.

Parameter 23: Lifeline Association Group Report To Send

Lifeline Association Group Report To Send Report to send to the Lifeline Association Group upon change in thermostat state. 

Bitmask values:

  • 1 = Temperature
  • 2 = Heat Setpoint
  • 4 = Cool Setpoint
  • 8 = Thermostat Heat/Cooling Mode
  • 16 = Fan Mode
  • 32 = Fan State
  • 64 = Operating State
  • 128 = Schedule (send CC parameter 38)
  • 256 = Setback (send CC parameter 40)
  • 512 = Run Hold (send CC parameter 39)
  • 1024 = Display Lock (send CC parameter 24)
  • 8192 = Battery Level
  • 16834 = Mechanical Relay State (send CC parameter 21)
  • 32768 = Thermostat State Config (send CC parameter 22)    This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 8319.

This parameter has the configuration ID config_23_4 and is of type INTEGER.

Parameter 24: Display Lock

Display Lock

The following option values may be configured -:

Value Description
0 Unlocked
1 Locked

The manufacturer defined default value is 0 (Unlocked).

This parameter has the configuration ID config_24_1 and is of type INTEGER.

Parameter 26: Backlight Timer

Backlight Timer Sets the time from last button press that the backlight will turn OFF Values in the range 10 to 30 may be set.

The manufacturer defined default value is 20.

This parameter has the configuration ID config_26_1 and is of type INTEGER.

Parameter 33: Max Heat Setpoint

Max Heat Setpoint Sets the maximum heating setpoint value Values in the range 30 to 109 may be set.

The manufacturer defined default value is 90.

This parameter has the configuration ID config_33_1 and is of type INTEGER.

Parameter 34: Min Cool Setpoint

Min Cool Setpoint Sets the minimum cooling setpoint value Values in the range 33 to 112 may be set.

The manufacturer defined default value is 61.

This parameter has the configuration ID config_34_1 and is of type INTEGER.

Parameter 38: Schedule Enable

Schedule Enable Enable or disable thermostat's local scheduler The following option values may be configured -:

Value Description
0 Disabled
1 Enabled

The manufacturer defined default value is 0 (Disabled).

This parameter has the configuration ID config_38_1 and is of type INTEGER.

Parameter 39: Run/Hold Mode

Run/Hold Mode 0 = Hold, 1 = Run The following option values may be configured -:

Value Description
0 Hold
1 Run

The manufacturer defined default value is 0 (Hold).

This parameter has the configuration ID config_39_1 and is of type INTEGER.

Parameter 40: Setback Mode

Setback Mode

The following option values may be configured -:

Value Description
0 No Setback
2 Unoccupied Mode

The manufacturer defined default value is 0 (No Setback).

This parameter has the configuration ID config_40_1 and is of type INTEGER.

Parameter 41: Un-Occupied HSP

Un-Occupied HSP Heat Setpoint for Unoccupied mode Values in the range 30 to 109 may be set.

The manufacturer defined default value is 62.

This parameter has the configuration ID config_41_1 and is of type INTEGER.

Parameter 42: Un-Occupied CSP

Un-Occupied CSP Cool Setpoint for Unoccupied mode Values in the range 33 to 112 may be set.

The manufacturer defined default value is 80.

This parameter has the configuration ID config_42_1 and is of type INTEGER.

Parameter 43: Remote Sensor 1 Node Number

Remote Sensor 1 Node Number Node number for Remote Sensor 1 Values in the range 0 to 252 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_43_1 and is of type INTEGER.

Parameter 46: Remote Sensor 1 Temperature

Remote Sensor 1 Temperature Temperature of Remote Sensor 1 Values in the range 0 to 112 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_46_1 and is of type INTEGER.

Parameter 48: Internal Sensor Temp Offset

Internal Sensor Temp Offset Internal Sensor Temperature Offset Values in the range -7 to 7 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_48_1 and is of type INTEGER.

Parameter 49: R1 Sensor Temp Offset

R1 Sensor Temp Offset R1 Sensor Temperature Offset Values in the range -7 to 7 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_49_1 and is of type INTEGER.

Parameter 54: Heat Timer

Heat Timer Heat Timer in hours Values in the range 0 to 4000 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_54_2 and is of type INTEGER.

Parameter 55: Cool Timer

Cool Timer Cool Timer in hours Values in the range 0 to 4000 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_55_2 and is of type INTEGER.

Parameter 61: Fan Purge Heat

Fan Purge Heat Fan purge period for Heat modeThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 90 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_61_1 and is of type INTEGER.

Parameter 62: Fan Purge Cool

Fan Purge Cool Fan purge period for Cool modeThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 90 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_62_1 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The GoControl GC-TBZ48 supports 3 association groups.

Group 1: Group 1

Lifeline

Association group 1 supports 5 nodes.

Group 2: Group 2

Association group 2 supports 5 nodes.

Group 3: Group 3

Association group 3 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SCENE_ACTIVATION_V1
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V1
COMMAND_CLASS_THERMOSTAT_MODE_V1
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V1
COMMAND_CLASS_THERMOSTAT_SETPOINT_V1
COMMAND_CLASS_THERMOSTAT_FAN_MODE_V1
COMMAND_CLASS_THERMOSTAT_FAN_STATE_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_CLOCK_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_MULTI_CMD_V1