This describes the Z-Wave device GoControl GC-TBZ48, manufactured by Linear Corp with the thing type UID of linear_gctbz48_00_000
.
The device is in the category of HVAC, defining Air condition devices, Fans.
The GoControl GC-TBZ48 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The Z-Wave Thermostat (GC-TBZ48) is a programmable, Z-Wave communications thermostat. It can be powered using 24VAC (if both “R”&”C”wires are available at the thermostat), or using four (4) AA batteries. Using Z-Wave technology, end users have the ability to use the 2GIG Go!Control panel to control the thermostat, configure programming settings, as well as to display current conditions in the home or office.
- Set your primary controller to Include, add or Install mode, to add the thermostat as a node on your network (see your controller’s user manual for detailed instructions).
- Press any button to take thermostat out of sleep mode.
- Press and hold FAN button for 5 seconds. SETUP will be displayed in the status display line.
- Scroll to “Z-Wave” using up/down buttons. Press SELECT.
- When prompted by your Z-Wave controller, Press the YES button in the Z-Wave Install screen.
- Press SELECT (mode button) to add thermostat to network.
- Display line should flash WAIT then SUCCESS if Z-Wave connection is made.
- If Z-Wave does not connect to controller, WAIT, then FAIL will flash in status display line.
- If thermostat fails to connect, repeat Steps three (3) through (7) to re-try connecting.
- Set your primary controller to Include, add or Install mode, to add the thermostat as a node on your network (see your controller’s user manual for detailed instructions).
- Press any button to take thermostat out of sleep mode.
- Press and hold FAN button for 5 seconds. SETUP will be displayed in the status display line.
- Scroll to “Z-Wave” using up/down buttons. Press SELECT.
- When prompted by your Z-Wave controller, Press the YES button in the Z-Wave Install screen.
- Press SELECT (mode button) to add thermostat to network.
- Display line should fl ash WAIT then SUCCESS if Z-Wave connection is made.
- If Z-Wave does not connect to controller, WAIT, then FAIL will flash in status display line.
The following table summarises the channels available for the GoControl GC-TBZ48 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Scene Number | scene_number | scene_number | Number | |
Sensor (temperature) | sensor_temperature | sensor_temperature | Temperature | Number:Temperature |
Thermostat mode | thermostat_mode | thermostat_mode | Temperature | Number |
Operating State | thermostat_state | thermostat_state | Temperature | Number |
Setpoint (cooling) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature |
Setpoint (heating) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature |
Thermostat fan mode | thermostat_fanmode | thermostat_fanmode | ||
Thermostat fan state | thermostat_fanstate | thermostat_fanstate | ||
Battery Level | battery-level | system.battery_level | Battery | Number |
Clock Time Offset | time_offset | time_offset | Time | Number |
Triggers when a scene button is pressed.
The scene_number
channel is of type scene_number
and supports the Number
item.
Indicates the current temperature.
The sensor_temperature
channel is of type sensor_temperature
and supports the Number:Temperature
item and is in the Temperature
category.
Sets the thermostat.
The thermostat_mode
channel is of type thermostat_mode
and supports the Number
item and is in the Temperature
category.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Off |
1 | Heat |
2 | Cool |
3 | Auto |
4 | Aux Heat |
5 | Resume |
6 | Fan Only |
7 | Furnace |
8 | Dry Air |
9 | Moist Air |
10 | Auto Changeover |
11 | Heat Economy |
12 | Cool Economy |
13 | Away |
Sets the thermostat operating state.
The thermostat_state
channel is of type thermostat_state
and supports the Number
item and is in the Temperature
category.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Idle |
1 | Heating |
2 | Cooling |
3 | Fan Only |
4 | Pending Heat |
5 | Pending Cool |
6 | Vent / Economiser |
Sets the thermostat setpoint.
The thermostat_setpoint
channel is of type thermostat_setpoint
and supports the Number:Temperature
item and is in the Heating
category.
Sets the thermostat setpoint.
The thermostat_setpoint
channel is of type thermostat_setpoint
and supports the Number:Temperature
item and is in the Heating
category.
Channel type information on this channel is not found.
Channel type information on this channel is not found.
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The system.battery-level
channel is of type system.battery-level
and supports the Number
item and is in the Battery
category.
This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.
Provides the current time difference for the devices time.
The time_offset
channel is of type time_offset
and supports the Number
item and is in the Time
category.
The following table provides a summary of the 38 configuration parameters available in the GoControl GC-TBZ48. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | System Type | System Type |
2 | Fan Type | Fan Type |
3 | Change Over Type | Change Over Type |
4 | 2nd Stage Heat Enable | 2nd Stage Heat Enable |
5 | Aux Heat Enable | Aux Heat Enable |
6 | 2nd Stage Cool Enable | 2nd Stage Cool Enable |
7 | Temperature Unit | Temperature Unit |
8 | Minimum Off Time | Minimum Off Time |
9 | Minimum Run Time | Minimum Run Time |
10 | Setpoint H/C Delta | Setpoint H/C Delta |
11 | H Delta Stage 1 ON | H Delta Stage 1 ON |
12 | H Delta Stage 1 OFF | H Delta Stage 1 OFF |
13 | H Delta Stage 2 ON | H Delta Stage 2 ON |
14 | H Delta Stage 2 OFF | H Delta Stage 2 OFF |
15 | H Delta Aux ON | H Delta Aux ON |
16 | H Delta Stage 3 OFF | H Delta Stage 3 OFF |
17 | C Delta Stage 1 ON | C Delta Stage 1 ON |
18 | C Delta Stage 1 OFF | C Delta Stage 1 OFF |
19 | C Delta Stage 2 ON | C Delta Stage 2 ON |
20 | C Delta Stage 2 OFF | C Delta Stage 2 OFF |
23 | Lifeline Association Group Report To Send | Lifeline Association Group Report To Send |
24 | Display Lock | Display Lock |
26 | Backlight Timer | Backlight Timer |
33 | Max Heat Setpoint | Max Heat Setpoint |
34 | Min Cool Setpoint | Min Cool Setpoint |
38 | Schedule Enable | Schedule Enable |
39 | Run/Hold Mode | Run/Hold Mode |
40 | Setback Mode | Setback Mode |
41 | Un-Occupied HSP | Un-Occupied HSP |
42 | Un-Occupied CSP | Un-Occupied CSP |
43 | Remote Sensor 1 Node Number | Remote Sensor 1 Node Number |
46 | Remote Sensor 1 Temperature | Remote Sensor 1 Temperature |
48 | Internal Sensor Temp Offset | Internal Sensor Temp Offset |
49 | R1 Sensor Temp Offset | R1 Sensor Temp Offset |
54 | Heat Timer | Heat Timer |
55 | Cool Timer | Cool Timer |
61 | Fan Purge Heat | Fan Purge Heat |
62 | Fan Purge Cool | Fan Purge Cool |
System Type
The following option values may be configured -:
Value | Description |
---|---|
0 | Standard |
1 | Heat Pump |
The manufacturer defined default value is 0
(Standard).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Fan Type
- 0 = Gas (no fan w/Heat)
- 1 = Electric (Fan w/Heat) The following option values may be configured -:
Value | Description |
---|---|
0 | Gas |
1 | Electric |
The manufacturer defined default value is 0
(Gas).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Change Over Type
The following option values may be configured -:
Value | Description |
---|---|
0 | w/Cool |
1 | w/Heat |
The manufacturer defined default value is 0
(w/Cool).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
2nd Stage Heat Enable
The following option values may be configured -:
Value | Description |
---|---|
0 | Disabled |
1 | Enabled |
The manufacturer defined default value is 0
(Disabled).
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Aux Heat Enable
The following option values may be configured -:
Value | Description |
---|---|
0 | Disabled |
1 | Enabled |
The manufacturer defined default value is 0
(Disabled).
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
2nd Stage Cool Enable
The following option values may be configured -:
Value | Description |
---|---|
0 | Disabled |
1 | Enabled |
The manufacturer defined default value is 0
(Disabled).
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
Temperature Unit
The following option values may be configured -:
Value | Description |
---|---|
0 | Celsius |
1 | Fahrenheit |
The manufacturer defined default value is 1
(Fahrenheit).
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
Minimum Off Time Sets the Minimum Off Time (MOT) delay before another heating/cooling cycle can begin Values in the range 5 to 9 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_8_1
and is of type INTEGER
.
Minimum Run Time Sets the Minimum Run Time (MRT) delay before a heating/cooling cycle can turn off Values in the range 3 to 9 may be set.
The manufacturer defined default value is 3
.
This parameter has the configuration ID config_9_1
and is of type INTEGER
.
Setpoint H/C Delta Sets the minimum separation between heating and cooling setpoints Values in the range 3 to 15 may be set.
The manufacturer defined default value is 3
.
This parameter has the configuration ID config_10_1
and is of type INTEGER
.
H Delta Stage 1 ON Sets the delta from setpoint that stage 1 heating starts Values in the range 1 to 6 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_11_1
and is of type INTEGER
.
H Delta Stage 1 OFF Sets the delta from setpoint that stage 1 heating stops Values in the range 0 to 5 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_12_1
and is of type INTEGER
.
H Delta Stage 2 ON Sets the delta from setpoint that stage 2 heating starts Values in the range 2 to 7 may be set.
The manufacturer defined default value is 2
.
This parameter has the configuration ID config_13_1
and is of type INTEGER
.
H Delta Stage 2 OFF Sets the delta from setpoint that stage 2 heating stops Values in the range 0 to 6 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_14_1
and is of type INTEGER
.
H Delta Aux ON Sets the delta from setpoint that stage 3 heating starts Values in the range 3 to 8 may be set.
The manufacturer defined default value is 3
.
This parameter has the configuration ID config_15_1
and is of type INTEGER
.
H Delta Stage 3 OFF Sets the delta from setpoint that stage 3 heating stops Values in the range 0 to 7 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_16_1
and is of type INTEGER
.
C Delta Stage 1 ON Sets the delta from setpoint that stage 1 cooling starts Values in the range 1 to 6 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_17_1
and is of type INTEGER
.
C Delta Stage 1 OFF Sets the delta from setpoint that stage 1 cooling stops Values in the range 0 to 5 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_18_1
and is of type INTEGER
.
C Delta Stage 2 ON Sets the delta from setpoint that stage 2 cooling starts Values in the range 2 to 7 may be set.
The manufacturer defined default value is 2
.
This parameter has the configuration ID config_19_1
and is of type INTEGER
.
C Delta Stage 2 OFF Sets the delta from setpoint that stage 2 cooling stops Values in the range 0 to 6 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_20_1
and is of type INTEGER
.
Lifeline Association Group Report To Send Report to send to the Lifeline Association Group upon change in thermostat state.
Bitmask values:
- 1 = Temperature
- 2 = Heat Setpoint
- 4 = Cool Setpoint
- 8 = Thermostat Heat/Cooling Mode
- 16 = Fan Mode
- 32 = Fan State
- 64 = Operating State
- 128 = Schedule (send CC parameter 38)
- 256 = Setback (send CC parameter 40)
- 512 = Run Hold (send CC parameter 39)
- 1024 = Display Lock (send CC parameter 24)
- 8192 = Battery Level
- 16834 = Mechanical Relay State (send CC parameter 21)
- 32768 = Thermostat State Config (send CC parameter 22) This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 8319
.
This parameter has the configuration ID config_23_4
and is of type INTEGER
.
Display Lock
The following option values may be configured -:
Value | Description |
---|---|
0 | Unlocked |
1 | Locked |
The manufacturer defined default value is 0
(Unlocked).
This parameter has the configuration ID config_24_1
and is of type INTEGER
.
Backlight Timer Sets the time from last button press that the backlight will turn OFF Values in the range 10 to 30 may be set.
The manufacturer defined default value is 20
.
This parameter has the configuration ID config_26_1
and is of type INTEGER
.
Max Heat Setpoint Sets the maximum heating setpoint value Values in the range 30 to 109 may be set.
The manufacturer defined default value is 90
.
This parameter has the configuration ID config_33_1
and is of type INTEGER
.
Min Cool Setpoint Sets the minimum cooling setpoint value Values in the range 33 to 112 may be set.
The manufacturer defined default value is 61
.
This parameter has the configuration ID config_34_1
and is of type INTEGER
.
Schedule Enable Enable or disable thermostat's local scheduler The following option values may be configured -:
Value | Description |
---|---|
0 | Disabled |
1 | Enabled |
The manufacturer defined default value is 0
(Disabled).
This parameter has the configuration ID config_38_1
and is of type INTEGER
.
Run/Hold Mode 0 = Hold, 1 = Run The following option values may be configured -:
Value | Description |
---|---|
0 | Hold |
1 | Run |
The manufacturer defined default value is 0
(Hold).
This parameter has the configuration ID config_39_1
and is of type INTEGER
.
Setback Mode
The following option values may be configured -:
Value | Description |
---|---|
0 | No Setback |
2 | Unoccupied Mode |
The manufacturer defined default value is 0
(No Setback).
This parameter has the configuration ID config_40_1
and is of type INTEGER
.
Un-Occupied HSP Heat Setpoint for Unoccupied mode Values in the range 30 to 109 may be set.
The manufacturer defined default value is 62
.
This parameter has the configuration ID config_41_1
and is of type INTEGER
.
Un-Occupied CSP Cool Setpoint for Unoccupied mode Values in the range 33 to 112 may be set.
The manufacturer defined default value is 80
.
This parameter has the configuration ID config_42_1
and is of type INTEGER
.
Remote Sensor 1 Node Number Node number for Remote Sensor 1 Values in the range 0 to 252 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_43_1
and is of type INTEGER
.
Remote Sensor 1 Temperature Temperature of Remote Sensor 1 Values in the range 0 to 112 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_46_1
and is of type INTEGER
.
Internal Sensor Temp Offset Internal Sensor Temperature Offset Values in the range -7 to 7 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_48_1
and is of type INTEGER
.
R1 Sensor Temp Offset R1 Sensor Temperature Offset Values in the range -7 to 7 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_49_1
and is of type INTEGER
.
Heat Timer Heat Timer in hours Values in the range 0 to 4000 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_54_2
and is of type INTEGER
.
Cool Timer Cool Timer in hours Values in the range 0 to 4000 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_55_2
and is of type INTEGER
.
Fan Purge Heat Fan purge period for Heat modeThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 90 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_61_1
and is of type INTEGER
.
Fan Purge Cool Fan purge period for Cool modeThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 90 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_62_1
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The GoControl GC-TBZ48 supports 3 association groups.
Lifeline
Association group 1 supports 5 nodes.
Association group 2 supports 5 nodes.
Association group 3 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SCENE_ACTIVATION_V1 | |
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V1 | |
COMMAND_CLASS_THERMOSTAT_MODE_V1 | |
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V1 | |
COMMAND_CLASS_THERMOSTAT_SETPOINT_V1 | |
COMMAND_CLASS_THERMOSTAT_FAN_MODE_V1 | |
COMMAND_CLASS_THERMOSTAT_FAN_STATE_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_CLOCK_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_MULTI_CMD_V1 |