Skip to content

Latest commit

 

History

History
executable file
·
83 lines (47 loc) · 3.77 KB

vrcs1_0_0.md

File metadata and controls

executable file
·
83 lines (47 loc) · 3.77 KB
layout title
documentation
VRCS1 - ZWave

{% include base.html %}

VRCS1 1-Scene Controller

This describes the Z-Wave device VRCS1, manufactured by Leviton with the thing type UID of leviton_vrcs1_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

VRCS1 product image

The VRCS1 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

Leviton VRCS1 Vizia RF+ 1-Button Scene Controller Switch for Multi-Location Scene Control - no local load control

Inclusion Information

  1. To access Program mode, engage the air-gap switch by gently pressing the top of the push pad until the bottom lifts completely out of the frame and a click is heard (refer to figure). Wait 5 seconds and then press the push pad back into the frame and hold push pad until the LED turns Amber. Release the push pad and the LED should blink Amber. You are now in Programming mode. NOTE: If the LED on the 1-scene controller turns solid Red while including, there has been a communication error.
  2. While standing close to the 1-scene controller (approximately 2-5 ft.), press the center button on the Programmer/Remote to device in the network. NOTE: Only one device may be included at any time

Exclusion Information

  1. To access Program mode, engage the air-gap switch by gently pressing the top of the push pad until the bottom lifts completely out of the frame and a click is heard (refer to figure). Wait 5 seconds and then press the push pad back into the frame and hold push pad until the LED turns Amber. Release the push pad and the LED should blink Amber. You are now in Programming mode. NOTE: If the LED on the 1-scene controller turns solid Red while excluding, there has been a communication error.
  2. While standing close to the 1-scene controller (approximately 2-5 ft.), press the center button to device from the network.

Channels

The following table summarises the channels available for the VRCS1 -:

Channel Name Channel ID Channel Type Category Item Type
Scene Number [Deprecated] scene_number scene_number Number

Scene Number [Deprecated]

Triggers when a scene button is pressed.

The scene_number channel is of type scene_number and supports the Number item.

Note: This channel is marked as deprecated so should not be used.

Device Configuration

The device has no configuration parameters defined.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The VRCS1 supports 1 association group.

Group 1: Group1

Association group 1 supports 32 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_SCENE_ACTIVATION_V1 Linked to BASIC
COMMAND_CLASS_ASSOCIATION_V1

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.