914TRLv3 - ZWave

{% include base.html %}

914TRLv3 Touchpad Electronic Deadbolt

This describes the Z-Wave device 914TRLv3, manufactured by Black & Decker with the thing type UID of kwikset_914trlv3_00_000.

The device is in the category of Lock, defining Devices whose primary pupose is locking something.

914TRLv3 product image

The 914TRLv3 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

Overview

  • One touch locking
  • Dramatically reduced, all-metal interior 
  • 30 user codes plus master code 
  • BHMA grade 2 certified 
  • 20 minute fire rating - UL certified 
  • Full 128-bit encryption security 
  • SmartKey: Re-key the lock in seconds

Inclusion Information

Press button “A” on the lock one time to include it in your system.

Exclusion Information

Press button “A” on the lock one time to exclude it from your system.

General Usage Information

To completely reset the device and unilaterally have the lock forget about the controller (the controller will not forget about the lock!):

  1. Remove the batteries and discharge latent power (wait or press the programming button once the battery pack is removed).
  2. Hold the unlabeled programming button and insert the batteries while continuing to hold the button.
  3. Continue to hold the button until the lock beeps (~30 seconds).
  4. Press the programming button again.
  5. Wait a few moments and the lock will finish resetting itself.

Channels

The following table summarises the channels available for the 914TRLv3 -:

Channel Name Channel ID Channel Type Category Item Type
Door Lock lock_door lock_door Door Switch
Alarm (burglar) alarm_burglar alarm_burglar Door Switch
Alarm (access) alarm_access alarm_access Door Switch
Alarm (power) alarm_power alarm_power Energy Switch
Entry Notification alarm_entry alarm_entry Door Switch
Battery Level battery-level system.battery_level Battery Number
Clock Time Offset time_offset time_offset Time Number

Door Lock

Lock and unlock the door.

The lock_door channel is of type lock_door and supports the Switch item and is in the Door category. The following state translation is provided for this channel to the Switch item type -:

Value Label
ON Locked
OFF Unlocked

Alarm (burglar)

Indicates if the burglar alarm is triggered.

The alarm_burglar channel is of type alarm_burglar and supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Alarm (access)

Indicates if the access control alarm is triggered.

The alarm_access channel is of type alarm_access and supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Alarm (power)

Indicates if a power alarm is triggered.

The alarm_power channel is of type alarm_power and supports the Switch item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Entry Notification

Indicates if the entry alarm is triggered.

The alarm_entry channel is of type alarm_entry and supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
ON Open
OFF Closed

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The system.battery-level channel is of type system.battery-level and supports the Number item and is in the Battery category. This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.

Clock Time Offset

Provides the current time difference for the devices time.

The time_offset channel is of type time_offset and supports the Number item and is in the Time category.

Device Configuration

The following table provides a summary of the 7 configuration parameters available in the 914TRLv3. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 User Code 1 Type User Code 1 Type
31 Lock Status LED
31 Autolock setting
31 Buzzer
33 SKU (High 32bits) ASCII
34 SKU (Low 32bits) ASCII
40 Factory Reset Have lock perform factory reset. (1 will reset)
Lock Timeout Sets the time after which the door will auto lock

Parameter 1: User Code 1 Type

User Code 1 Type

<td>
  <strong>Description</strong>
</td>
<td>
  Reserved 
</td>
<td>
  Owner (Default)
</td>
<td>
  Reserved
</td>
<td>
  Guest (required for Year/Day schedules)
</td>
<td>
  Worker (required for week day schedules)
</td>
<td>
  Reserved 
</td>
<td>
  No User Code assigned 
</td>
Parameter Value
0x00
0x01
0x02
0x03
0x04
0x05 - 0xFE
0xFF
Values in the range 0 to 255 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 31: Lock Status LED

Values in the range 0 to 1 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_31_1_00000001 and is of type INTEGER. This is a read only parameter.

Parameter 31: Autolock setting

Values in the range 0 to 1 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_31_1_00000002 and is of type INTEGER. This is a read only parameter.

Parameter 31: Buzzer

Values in the range 0 to 1 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_31_1_00000004 and is of type INTEGER. This is a read only parameter.

Parameter 33: SKU (High 32bits)

ASCII

Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_33_4 and is of type INTEGER.

Parameter 34: SKU (Low 32bits)

ASCII

Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_34_4 and is of type INTEGER.

Parameter 40: Factory Reset

Have lock perform factory reset. (1 will reset)

Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_40_1_wo and is of type INTEGER. This is a write only parameter.

Lock Timeout

Sets the time after which the door will auto lock.

This parameter has the configuration ID doorlock_timeout and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The 914TRLv3 supports 2 association groups.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. The lock supports 2 association groups. Per Z-Wave Plus requirements, group 1 is assigned to the Lifeline group and can only support 1 node.

The Lifeline group supports the following unsolicited messages:

<td>
  <strong>Command</strong>
</td>
<td>
  Battery Report
</td>
<td>
  Door Lock Operation Report
</td>
<td>
  Notification Report
</td>
<td>
  <p>
    Device Reset Locally Notification
  </p>
</td>
Command Class
Command Class Battery
Command Class Door Lock 
Command Class Notification
Command Class Device Reset Locally 

Association group 1 supports 1 node.

Group 2: Doorlock notify report

Will provide all Notification Reports, via the Command Class Notification, generated by the lock.

Association group 2 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_DOOR_LOCK_LOGGING_V1
COMMAND_CLASS_SCHEDULE_ENTRY_LOCK_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_DOOR_LOCK_V1
COMMAND_CLASS_USER_CODE_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V4
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_TIME_PARAMETERS_V1
COMMAND_CLASS_SECURITY_V1

Documentation Links