This describes the Z-Wave device 914TRLv3, manufactured by Black & Decker with the thing type UID of kwikset_914trlv3_00_000
.
The device is in the category of Lock, defining Devices whose primary pupose is locking something.
The 914TRLv3 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
- One touch locking
- Dramatically reduced, all-metal interior
- 30 user codes plus master code
- BHMA grade 2 certified
- 20 minute fire rating - UL certified
- Full 128-bit encryption security
- SmartKey: Re-key the lock in seconds
Press button “A” on the lock one time to include it in your system.
Press button “A” on the lock one time to exclude it from your system.
To completely reset the device and unilaterally have the lock forget about the controller (the controller will not forget about the lock!):
- Remove the batteries and discharge latent power (wait or press the programming button once the battery pack is removed).
- Hold the unlabeled programming button and insert the batteries while continuing to hold the button.
- Continue to hold the button until the lock beeps (~30 seconds).
- Press the programming button again.
- Wait a few moments and the lock will finish resetting itself.
The following table summarises the channels available for the 914TRLv3 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Door Lock | lock_door | lock_door | Door | Switch |
Alarm (burglar) | alarm_burglar | alarm_burglar | Door | Switch |
Alarm (access) | alarm_access | alarm_access | Door | Switch |
Alarm (power) | alarm_power | alarm_power | Energy | Switch |
Entry Notification | alarm_entry | alarm_entry | Door | Switch |
Battery Level | battery-level | system.battery_level | Battery | Number |
Clock Time Offset | time_offset | time_offset | Time | Number |
Lock and unlock the door.
The lock_door
channel is of type lock_door
and supports the Switch
item and is in the Door
category.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Locked |
OFF | Unlocked |
Indicates if the burglar alarm is triggered.
The alarm_burglar
channel is of type alarm_burglar
and supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Indicates if the access control alarm is triggered.
The alarm_access
channel is of type alarm_access
and supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Indicates if a power alarm is triggered.
The alarm_power
channel is of type alarm_power
and supports the Switch
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Indicates if the entry alarm is triggered.
The alarm_entry
channel is of type alarm_entry
and supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Open |
OFF | Closed |
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The system.battery-level
channel is of type system.battery-level
and supports the Number
item and is in the Battery
category.
This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.
Provides the current time difference for the devices time.
The time_offset
channel is of type time_offset
and supports the Number
item and is in the Time
category.
The following table provides a summary of the 7 configuration parameters available in the 914TRLv3. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | User Code 1 Type | User Code 1 Type |
31 | Lock Status LED | |
31 | Autolock setting | |
31 | Buzzer | |
33 | SKU (High 32bits) | ASCII |
34 | SKU (Low 32bits) | ASCII |
40 | Factory Reset | Have lock perform factory reset. (1 will reset) |
Lock Timeout | Sets the time after which the door will auto lock |
User Code 1 Type
<td>
<strong>Description</strong>
</td>
<td>
Reserved
</td>
<td>
Owner (Default)
</td>
<td>
Reserved
</td>
<td>
Guest (required for Year/Day schedules)
</td>
<td>
Worker (required for week day schedules)
</td>
<td>
Reserved
</td>
<td>
No User Code assigned
</td>
Parameter Value |
0x00 |
0x01 |
0x02 |
0x03 |
0x04 |
0x05 - 0xFE |
0xFF |
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Values in the range 0 to 1 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_31_1_00000001
and is of type INTEGER
.
This is a read only parameter.
Values in the range 0 to 1 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_31_1_00000002
and is of type INTEGER
.
This is a read only parameter.
Values in the range 0 to 1 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_31_1_00000004
and is of type INTEGER
.
This is a read only parameter.
ASCII
Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_33_4
and is of type INTEGER
.
ASCII
Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_34_4
and is of type INTEGER
.
Have lock perform factory reset. (1 will reset)
Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_40_1_wo
and is of type INTEGER
.
This is a write only parameter.
Sets the time after which the door will auto lock.
This parameter has the configuration ID doorlock_timeout
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The 914TRLv3 supports 2 association groups.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. The lock supports 2 association groups. Per Z-Wave Plus requirements, group 1 is assigned to the Lifeline group and can only support 1 node.
The Lifeline group supports the following unsolicited messages:
<td>
<strong>Command</strong>
</td>
<td>
Battery Report
</td>
<td>
Door Lock Operation Report
</td>
<td>
Notification Report
</td>
<td>
<p>
Device Reset Locally Notification
</p>
</td>
Command Class |
Command Class Battery |
Command Class Door Lock |
Command Class Notification |
Command Class Device Reset Locally |
Association group 1 supports 1 node.
Will provide all Notification Reports, via the Command Class Notification, generated by the lock.
Association group 2 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_DOOR_LOCK_LOGGING_V1 | |
COMMAND_CLASS_SCHEDULE_ENTRY_LOCK_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_DOOR_LOCK_V1 | |
COMMAND_CLASS_USER_CODE_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V4 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_TIME_PARAMETERS_V1 | |
COMMAND_CLASS_SECURITY_V1 |