layout | title |
---|---|
documentation |
Kwikset 914C Convert Smart Lock - ZWave |
{% include base.html %}
This describes the Z-Wave device Kwikset 914C Convert Smart Lock, manufactured by Black & Decker with the thing type UID of kwikset_914c_00_000
.
The device is in the category of Lock, defining Devices whose primary pupose is locking something.
The Kwikset 914C Convert Smart Lock supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
Kwikset®, the leader in residential security, introduces the Smart Lock Convert Kit with Z-Wave.
Extend your smart home system to your current deadbolt, enabling your existing deadbolt to wirelessly communicate with your smart home or security system
Dramatically reduced, all-metal interior
Works with existing select single cylinder deadbolts
Initiate the process to add the lock to your system at your smart home controller.
Note: On some systems you may need to ensure you are using** "secure inclusion"**.
When prompted by your smart home system to add the lock, press button “A” on the lock interior one time. The red LED will illuminate when the lock enters Add Mode. Please allow time for the controller to add the lock to your system.
Note: Some controllers are required to be within close proximity to the lock (less than 12") while including for security reasons.
Follow your smart home system’s instructions to remove the lock from the network. When prompted by the system, press button A” on the lock interior once. The red LED will illuminate when the lock enters Remove mode.
Factory Reset:
A factory reset will delete all user codes associated with the lock and will remove itself from your smart home system.
Please only perform a factory reset when the primary controller is missing or inoperable.
To perform a factory reset, please perform the following:
- Remove the battery pack
- Press and HOLD the Program button while reinserting the battery pack.
- Keep holding the button for 30 seconds until the lock beeps and the status LED flashes red.
- Press the Program button once more. The status LED will flash green and red several times.
- After a few seconds, the lock will initiate the door handing process.
The following table summarises the channels available for the Kwikset 914C Convert Smart Lock -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Door Lock | lock_door | lock_door | Door | Switch |
Alarm (raw) | alarm_raw | alarm_raw | String | |
Battery Level | battery-level | system.battery_level | Battery | Number |
Lock and unlock the door.
The lock_door
channel is of type lock_door
and supports the Switch
item and is in the Door
category.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Locked |
OFF | Unlocked |
Provides alarm parameters as json string.
The alarm_raw
channel is of type alarm_raw
and supports the String
item. This is a read only channel so will only be updated following state changes from the device.
This channel sets, and provides the alarm state as a JSON string. It is designed for use in rules.
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The system.battery-level
channel is of type system.battery-level
and supports the Number
item and is in the Battery
category.
This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.
The following table provides a summary of the 5 configuration parameters available in the Kwikset 914C Convert Smart Lock. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
31 | Dipswitch Settings | Dipswitch Settings |
33 | First 4 bytes of SKU | SKU (length = 8 bytes) |
34 | Last 4 bytes of SKU | SKU (length = 8 bytes) |
35 | Lock Type | Report the Unique ID of the lock type |
40 | Factory Reset | Reset Lock to Factory Default |
Lock Timeout | Sets the time after which the door will auto lock |
Dipswitch Settings Configuration parameter is a one byte read only bit mask that returns the state of the user accessible dipswitches on the rear panel of the door lock. This is a read only parameter and cannot be used to set dipswitch settings.
The following table shows the definition for the bits being used in the returned value:
<td>
Description
</td>
<td>
Lock status LED (1:enabled)
</td>
<td>
Autolock setting (1:enabled)
</td>
<td>
Buzzer (1:enabled)
</td>
<td>
Handing Invert (1:enabled)
</td>
Bit |
0 (0x01) |
1 (0x02) |
2 (0x04) |
3 (0x08) |
Possible Values:
<td>
All features disabled
</td>
<td>
Lock status LED enabled
</td>
<td>
Autolock Enabled
</td>
<td>
Internal buzzer enabled
</td>
<td>
Handling invert enabled
</td>
<td>
Autolock & Lock status LED enabled
</td>
<td>
Internal buzzer and lock status LED enabled
</td>
<td>
Autolock, Internal buzzer, and lock status LED enabled
</td>
<td>
All Features enabled
</td>
1 |
2 |
4 |
8 |
3 |
5 |
7 |
15 |
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_31_1
and is of type INTEGER
.
This is a read only parameter.
SKU (length = 8 bytes) The configuration parameters 33 and 34 are used to set and get the SKU part numbers. The SKU is made up of 8 bytes. Each parameter consists of four bytes of data. Parameter 33 contains the first four most significant bytes of the SKU, while parameter 34 contains the four least significant bytes of the SKU.
When setting the SKU, it must be done in two set commands, one for each parameter. The order of programming the SKU does not matter.
Setting parameter 33 will program the first four bytes of the SKU. Setting parameter 34 will program the last 4 bytes of the SKU. Most printable values are accepted for the set command.
When getting the SKU, it must be done in two get commands, one for each parameter. The order of getting the SKU does not matter.
Getting parameter 33 will retrieve the first four bytes of the SKU. Getting parameter 34 will retrieve the last 4 bytes of the SKU. This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range -2147483647 to 2147483646 may be set.
The manufacturer defined default value is 32
.
This parameter has the configuration ID config_33_4
and is of type INTEGER
.
SKU (length = 8 bytes) The configuration parameters 33 and 34 are used to set and get the SKU part numbers. The SKU is made up of 8 bytes. Each parameter consists of four bytes of data. Parameter 33 contains the first four most significant bytes of the SKU, while parameter 34 contains the four least significant bytes of the SKU.
When setting the SKU, it must be done in two set commands, one for each parameter. The order of programming the SKU does not matter.
Setting parameter 33 will program the first four bytes of the SKU. Setting parameter 34 will program the last 4 bytes of the SKU. Most printable values are accepted for the set command.
When getting the SKU, it must be done in two get commands, one for each parameter. The order of getting the SKU does not matter.
Getting parameter 33 will retrieve the first four bytes of the SKU. Getting parameter 34 will retrieve the last 4 bytes of the SKU. This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range -2147483647 to 2147483646 may be set.
The manufacturer defined default value is 32
.
This parameter has the configuration ID config_34_4
and is of type INTEGER
.
Report the Unique ID of the lock type The configuration Parameter 35 is used as read-only to report the Unique ID of the lock type.
<td>
<strong>Unique ID</strong>
</td>
<td>
0x00 0x00
</td>
<td>
0x00 0x00
</td>
<td>
0x02 0x36
</td>
<td>
0x03 0x36
</td>
<td>
0x04 0x36
</td>
<td>
0x06 0x42
</td>
Released Board ID |
910 Z-wave (Legacy, FW 3.4) |
912 Z-wave (Legacy, FW 3.2) |
910 Z-wave |
912 Z-wave |
914 Z-wave |
916 Z-wave |
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_35_2
and is of type INTEGER
.
This is a read only parameter.
Reset Lock to Factory Default The configuration parameter 40 is a one byte field, used to set the lock to its default setting, known as a factory reset command.
Reading this parameter will always return a value of 0.
Writing a value of 1 to this parameter will cause both the lock and Z-Wave card to reset back to their default settings and will remove itself from the network. All network information, including associations will be cleared. Values in the range 0 to 1 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_40_1
and is of type INTEGER
.
Sets the time after which the door will auto lock.
This parameter has the configuration ID doorlock_timeout
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The Kwikset 914C Convert Smart Lock supports 2 association groups.
Lifeline Z-Wave Plus Lifeline Supports the following types of unsolicited messages:
<td>
<strong>Command</strong>
</td>
<td>
<strong>Info</strong>
</td>
<td>
Battery Report
</td>
<td>
Sends periodic battery reports containing the battery percentage.
</td>
<td>
Door Lock Operation Report
</td>
<td>
Upon power up, this message will be sent to allow the controller to sync up with the current lock status.
</td>
<td>
Notification Report
</td>
<td>
Many notification types will be sent for status and alarms. The following notification types are supported: Access Control (V2) and Power Management (V2).
</td>
<td>
Device Reset Locally Notification
</td>
<td>
This message will be sent to notify the smart home controller that the lock is resetting back to factory defaults and will be leaving the network.
</td>
Command Class |
Command Class Battery |
Command Class Door Lock |
Command Class Notification |
Command Class Device Reset Locally |
Association group 1 supports 1 node.
Doorlock notify group This group will provide all Notification reports as described for the Lifeline. This group allows other controllers, other than the lifeline, to receive these types of unsolicited messages as well.
It allows at most 5 other nodes to be associated with the lock and will provide all Notification Reports, via the Command Class Notification, generated by the lock.
Association group 2 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_DOOR_LOCK_V1 | |
COMMAND_CLASS_USER_CODE_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V4 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.