Kwikset SmartCode 910 Touchpad Electronic Deadbolt with Z-Wave

This describes the Z-Wave device Kwikset SmartCode 910, manufactured by Black & Decker with the thing type UID of kwikset_910_00_000.

The device is in the category of Lock, defining Devices whose primary pupose is locking something.

Kwikset SmartCode 910 product image

The Kwikset SmartCode 910 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

Overview

Kwikset®, the leader in residential security, introduces the SmartCode™ 910 Touchpad Electronic Deadbolt with Z-Wave.

  • Backlit keypad with One touch locking
  • 30 user codes
  • BHMA grade 2 certified
  • Full 128-bit encryption security
  • Drill and pick resistant backup keyway
  • SmartKey: Re-key the lock in seconds

Inclusion Information

  • Initiate the process to add the lock to your system at your smart home controller.
  • When prompted by your smart home system to add the lock, press button “A” on the lock interior one time. The red LED will illuminate when the lock enters Add Mode.
  • Please allow time for the controller to add the lock to your system.

Exclusion Information

  • Follow your smart home system’s instructions to remove the lock from the network.
  • When prompted by the system, press button A” on the lock interior once. 
  • The red LED will illuminate when the lock enters Remove mode. 

General Usage Information

A factory reset will delete all user codes associated with the lock and will remove itself from your smart home system. Please only perform a factory reset when the primary controller is missing or inoperable.

To perform a factory reset, please perform the following:  

  1. Remove the battery pack
  2. Press and HOLD the Program button while reinserting the battery pack.
  3. Keep holding the button for 30 seconds until the lock beeps and the status LED flashes red.
  4. Press the Program button once more.  The status LED will flash green and red several times.
  5. After a few seconds, the lock will initiate the door handing process.

Channels

The following table summarises the channels available for the Kwikset SmartCode 910 -:

Channel Name Channel ID Channel Type Category Item Type
Door Lock lock_door lock_door Door Switch
Alarm (access) alarm_access alarm_access Door Switch
Alarm (burglar) alarm_burglar alarm_burglar Door Switch
Alarm (power) alarm_power alarm_power Energy Switch
Battery Level battery-level system.battery_level Battery Number
Clock Time Offset time_offset time_offset Time Number

Door Lock

Lock and unlock the door.

The lock_door channel is of type lock_door and supports the Switch item and is in the Door category. The following state translation is provided for this channel to the Switch item type -:

Value Label
ON Locked
OFF Unlocked

Alarm (access)

Indicates if the access control alarm is triggered.

The alarm_access channel is of type alarm_access and supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Alarm (burglar)

Indicates if the burglar alarm is triggered.

The alarm_burglar channel is of type alarm_burglar and supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Alarm (power)

Indicates if a power alarm is triggered.

The alarm_power channel is of type alarm_power and supports the Switch item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The system.battery-level channel is of type system.battery-level and supports the Number item and is in the Battery category. This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.

Clock Time Offset

Provides the current time difference for the devices time.

The time_offset channel is of type time_offset and supports the Number item and is in the Time category.

Device Configuration

The following table provides a summary of the 5 configuration parameters available in the Kwikset SmartCode 910. Detailed information on each parameter can be found in the sections below.

Param Name Description
31 Dipswitch Settings Dipswitch Settings
33 first four most significant bytes of the SKU SKU (length = 8 bytes)
34 four least significant bytes of the SKU. SKU (length = 8 bytes)
35 Lock Type Report the Unique ID of the lock type
40 Factory Reset Reset Lock to Factory Default
Lock Timeout Sets the time after which the door will auto lock

Parameter 31: Dipswitch Settings

Dipswitch Settings Configuration parameter is a one byte read only bit mask that returns the state of the user accessible dipswitches on the rear panel of the door lock. This is a read only parameter and cannot be used to set dipswitch settings.

The following table shows the definition for the bits being used in the returned value: 

<td>
  Description
</td>
<td>
  Lock status LED (1:enabled)
</td>
<td>
  Autolock setting (1:enabled)
</td>
<td>
  Buzzer (1:enabled)
</td>
<td>
  <p>
    Handing Invert (1:enabled)
  </p>
</td>
Bit
0 (0x01)
1 (0x02)
2 (0x04)
3 (0x08)

Possible Values:

<td>
  All features disabled
</td>
<td>
  Lock status LED enabled
</td>
<td>
  Autolock Enabled
</td>
<td>
  Internal buzzer enabled
</td>
<td>
  Handling invert enabled
</td>
<td>
  Autolock & Lock status LED enabled
</td>
<td>
  Internal buzzer and lock status LED enabled
</td>
<td>
  Autolock, Internal buzzer, and lock status LED enabled
</td>
<td>
  All Features enabled
</td>
1
2
4
8
3
5
7
15
Values in the range 0 to 15 may be set.

The manufacturer defined default value is 5.

This parameter has the configuration ID config_31_1 and is of type INTEGER. This is a read only parameter.

Parameter 33: first four most significant bytes of the SKU

SKU (length = 8 bytes) The configuration parameters 33 and 34 are used to set and get the SKU part numbers. The SKU is made up of 8 bytes. Each parameter consists of four bytes of data. Parameter 33 contains the first four most significant bytes of the SKU, while parameter 34 contains the four least significant bytes of the SKU.

When setting the SKU, it must be done in two set commands, one for each parameter. The order of programming the SKU does not matter.

Setting parameter 33 will program the first four bytes of the SKU. Setting parameter 34 will program the last 4 bytes of the SKU. Most printable values are accepted for the set command.

When getting the SKU, it must be done in two get commands, one for each parameter. The order of getting the SKU does not matter.

Getting parameter 33 will retrieve the first four bytes of the SKU. Getting parameter 34 will retrieve the last 4 bytes of the SKU. This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 32 to 126 may be set.

The manufacturer defined default value is 32.

This parameter has the configuration ID config_33_4 and is of type INTEGER.

Parameter 34: four least significant bytes of the SKU.

SKU (length = 8 bytes) The configuration parameters 33 and 34 are used to set and get the SKU part numbers. The SKU is made up of 8 bytes. Each parameter consists of four bytes of data. Parameter 33 contains the first four most significant bytes of the SKU, while parameter 34 contains the four least significant bytes of the SKU.

When setting the SKU, it must be done in two set commands, one for each parameter. The order of programming the SKU does not matter.

Setting parameter 33 will program the first four bytes of the SKU. Setting parameter 34 will program the last 4 bytes of the SKU. Most printable values are accepted for the set command.

When getting the SKU, it must be done in two get commands, one for each parameter. The order of getting the SKU does not matter.

Getting parameter 33 will retrieve the first four bytes of the SKU. Getting parameter 34 will retrieve the last 4 bytes of the SKU.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 32 to 126 may be set.

The manufacturer defined default value is 32.

This parameter has the configuration ID config_34_4 and is of type INTEGER.

Parameter 35: Lock Type

Report the Unique ID of the lock type The configuration Parameter 35 is used as read-only to report the Unique ID of the lock type.

<td>
  <strong>Unique ID</strong>
</td>
<td>
  0x00 0x00
</td>
<td>
  0x00 0x00
</td>
<td>
  0x02 0x36
</td>
<td>
  0x03 0x36
</td>
<td>
  0x04 0x36
</td>
<td>
  0x06 0x42
</td>
Released Board ID
910 Z-wave (Legacy, FW 3.4)
912 Z-wave (Legacy, FW 3.2)
910 Z-wave
912 Z-wave
914 Z-wave
916 Z-wave
Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_35_2 and is of type INTEGER. This is a read only parameter.

Parameter 40: Factory Reset

Reset Lock to Factory Default

The following option values may be configured -:

Value Description
0 Normal operation
1 have lock perform factory reset

The manufacturer defined default value is 0 (Normal operation).

This parameter has the configuration ID config_40_1 and is of type INTEGER.

Lock Timeout

Sets the time after which the door will auto lock.

This parameter has the configuration ID doorlock_timeout and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The Kwikset SmartCode 910 supports 2 association groups.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Z-Wave Plus Lifeline Supports the following types of unsolicited messages: Battery Report - sends periodic battery reports containing the battery percentage. Door Lock Operation Report - upon power up, this message will be sent to allow the controller to sync up with the current lock status. Notification Report - many notification types will be sent for status and alarms. The following notification types are supported: Access Control (V2), Home Security (V2), and Power Management (V2). Device Reset Locally Notification - this message will be sent to notify the smart home controller that the lock is resetting back to factory defaults and will be leaving the network.

Association group 1 supports 1 node.

Group 2: Group 2

This group will provide all Notification reports as described for the Lifeline. This group allows other controllers, other than the lifeline, to receive these types of unsolicited messages as well.

Association group 2 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_DOOR_LOCK_LOGGING_V1
COMMAND_CLASS_SCHEDULE_ENTRY_LOCK_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_DOOR_LOCK_V1
COMMAND_CLASS_USER_CODE_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V4
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_TIME_PARAMETERS_V1
COMMAND_CLASS_SECURITY_V1

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.