KONOzw - ZWave

{% include base.html %}

KONOzw LUX KONOzw Smart Hub Thermostat

This describes the Z-Wave device KONOzw, manufactured by Johnson Controls with the thing type UID of johnson_konozw_00_000.

The device is in the category of HVAC, defining Air condition devices, Fans.

KONOzw product image

The KONOzw supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

Overview

KONOzw is the smart hub thermostat made with you in mind. It seamlessly connects to many smart hubs and blends in or stands out with its interchangeable Décorsnap covers™. KONOzw makes it easier than ever to personalize your comfort, décor, and savings.

Inclusion Information

  • In HOME screen, press the knob once to enter the menu settings 

  • Rotate the knob to select wireless symbol, then press the knob to enter the inclusion/exclusion menu

  • In the inclusion/exclusion menu, select ADD and press the knob to confirm

  • The device will begin the adding process

Exclusion Information

  • In HOME screen, press the knob once to enter the menu settings 

  • Rotate the knob to select wireless symbol, then press the knob to enter the inclusion/exclusion menu

  • In the inclusion/exclusion menu, select RST and press the knob to confirm

  • The device will begin the removal process

Channels

The following table summarises the channels available for the KONOzw -:

Channel Name Channel ID Channel Type Category Item Type
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number:Temperature
Thermostat mode thermostat_mode thermostat_mode Temperature Number
Operating State thermostat_state thermostat_state Temperature Number
Setpoint (heating) thermostat_setpoint thermostat_setpoint Heating Number:Temperature
Setpoint (cooling) thermostat_setpoint thermostat_setpoint Heating Number:Temperature
Setpoint (auto changeover) thermostat_setpoint thermostat_setpoint Heating Number:Temperature
Setpoint (moist air) thermostat_setpoint thermostat_setpoint Heating Number:Temperature
Thermostat fan mode thermostat_fanmode thermostat_fanmode
Thermostat fan state thermostat_fanstate thermostat_fanstate
Alarm (power) alarm_power alarm_power Energy Switch
Battery Level battery-level system.battery_level Battery Number
Clock Time Offset time_offset time_offset Time Number

Sensor (temperature)

Indicates the current temperature.

The sensor_temperature channel is of type sensor_temperature and supports the Number:Temperature item and is in the Temperature category.

Thermostat mode

Sets the thermostat.

The thermostat_mode channel is of type thermostat_mode and supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Off
1 Heat
2 Cool
3 Auto
4 Aux Heat
5 Resume
6 Fan Only
7 Furnace
8 Dry Air
9 Moist Air
10 Auto Changeover
11 Heat Economy
12 Cool Economy
13 Away

Operating State

Sets the thermostat operating state.

The thermostat_state channel is of type thermostat_state and supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Idle
1 Heating
2 Cooling
3 Fan Only
4 Pending Heat
5 Pending Cool
6 Vent / Economiser

Setpoint (heating)

Sets the thermostat setpoint.

The thermostat_setpoint channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Setpoint (cooling)

Sets the thermostat setpoint.

The thermostat_setpoint channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Setpoint (auto changeover)

Sets the thermostat setpoint.

The thermostat_setpoint channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Setpoint (moist air)

Sets the thermostat setpoint.

The thermostat_setpoint channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Thermostat fan mode

Channel type information on this channel is not found.

Thermostat fan state

Channel type information on this channel is not found.

Alarm (power)

Indicates if a power alarm is triggered.

The alarm_power channel is of type alarm_power and supports the Switch item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The system.battery-level channel is of type system.battery-level and supports the Number item and is in the Battery category. This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.

Clock Time Offset

Provides the current time difference for the devices time.

The time_offset channel is of type time_offset and supports the Number item and is in the Time category.

Device Configuration

The following table provides a summary of the 14 configuration parameters available in the KONOzw. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 User Temperature Calibration Step-size = 10
2 Temperature Unit (C/F) 0=C, 1=F
3 Available Control mode 0=Auto Heat & Cool, 1=Heat Only, 2=Cool Only, 3=No Auto Heat & Cool, 4=Reserved
4 System Type 0=Furnace Gas, 1=Furnace Electric, 2=Heat Pump, 3=Boiler no fan, 4=Reserved
5 Reversal valve Type in Heat Pump 0=O-valve, 1=B-valve
8 Temperature Limit - Heat Max Increment by 1F
9 Temperature Limit - Heat Min Increment by 1F
10 Temperature Limit - Cool Max Increment by 1F. Actual allowable range depends on the heat set point limit
11 Temperature Limit - Cool Min Increment by 1F. Actual allowable range depends on the heat set point limit
12 Temperature Minimum Setpoint Deadband 100 to 250, stepsize = 10
14 Ambient Temperature Change Stepsize 0.5F – 4F range with a step-size of 0.5F (0.25C)
15 Regular Ambient Temperature Reporting Interval 1-24 hours
16 Regular Operating State Reporting Interval 1-24 hours
17 Command Echo Enable 0=Disable, 1=Enable

Parameter 1: User Temperature Calibration

Step-size = 10 Adjusts room temperature display to match a calibrated value. Values in the range -250 to 250 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_1_2 and is of type INTEGER.

Parameter 2: Temperature Unit (C/F)

0=C, 1=F

The following option values may be configured -:

Value Description
0 Celsius
1 Fahrenheit (Default)

The manufacturer defined default value is 1 (Fahrenheit (Default)).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Available Control mode

0=Auto Heat & Cool, 1=Heat Only, 2=Cool Only, 3=No Auto Heat & Cool, 4=Reserved

The following option values may be configured -:

Value Description
0 Heat and Cool, Auto (Default)
1 Heat Only
2 Cool Only
3 Heat and Cool, no Auto
4 Reserved

The manufacturer defined default value is 0 (Heat and Cool, Auto (Default)).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: System Type

0=Furnace Gas, 1=Furnace Electric, 2=Heat Pump, 3=Boiler no fan, 4=Reserved

The following option values may be configured -:

Value Description
0 Furnace Gas (Default)
1 Furnace Electric
2 Heat Pump
3 Boiler no fan
4 Reserved

The manufacturer defined default value is 0 (Furnace Gas (Default)).

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Reversal valve Type in Heat Pump

0=O-valve, 1=B-valve

The following option values may be configured -:

Value Description
0 O-valve (Default)
1 B-valve

The manufacturer defined default value is 0 (O-valve (Default)).

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 8: Temperature Limit - Heat Max

Increment by 1F 60.00F-90.00F (16C-32C) Values in the range 60 to 90 may be set.

The manufacturer defined default value is 90.

This parameter has the configuration ID config_8_2 and is of type INTEGER.

Parameter 9: Temperature Limit - Heat Min

Increment by 1F 45.00F-60.00F (7C-16C) Values in the range 45 to 60 may be set.

The manufacturer defined default value is 45.

This parameter has the configuration ID config_9_2 and is of type INTEGER.

Parameter 10: Temperature Limit - Cool Max

Increment by 1F. Actual allowable range depends on the heat set point limit 60F-95F (16C-35C) Values in the range 60 to 95 may be set.

The manufacturer defined default value is 95.

This parameter has the configuration ID config_10_2 and is of type INTEGER.

Parameter 11: Temperature Limit - Cool Min

Increment by 1F. Actual allowable range depends on the heat set point limit 50F-75F (10C-24C) Values in the range 50 to 75 may be set.

The manufacturer defined default value is 50.

This parameter has the configuration ID config_11_2 and is of type INTEGER.

Parameter 12: Temperature Minimum Setpoint Deadband

100 to 250, stepsize = 10 The Dead Band is a temperature range in which neither COOL or HEAT turns on when in AUTO mode. Values in the range 100 to 250 may be set.

The manufacturer defined default value is 200.

This parameter has the configuration ID config_12_2 and is of type INTEGER.

Parameter 14: Ambient Temperature Change Stepsize

0.5F – 4F range with a step-size of 0.5F (0.25C)

The following option values may be configured -:

Value Description
50 0.5F (0.25C)
100 1.0F (0.50C)
150 1.5F (0.75C)
200 2.0F (1.00C)
250 2.5F (1.25C)
300 3.0F (1.50C)
350 3.5F (1.75C)
400 4.0F (2.00C)

The manufacturer defined default value is 50 (0.5F (0.25C)).

This parameter has the configuration ID config_14_2 and is of type INTEGER.

Parameter 15: Regular Ambient Temperature Reporting Interval

1-24 hours

Values in the range 1 to 24 may be set.

The manufacturer defined default value is 4.

This parameter has the configuration ID config_15_1 and is of type INTEGER.

Parameter 16: Regular Operating State Reporting Interval

1-24 hours

Values in the range 1 to 24 may be set.

The manufacturer defined default value is 4.

This parameter has the configuration ID config_16_1 and is of type INTEGER.

Parameter 17: Command Echo Enable

0=Disable, 1=Enable

Values in the range 0 to 1 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_17_1 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The KONOzw supports 1 association group.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Z-Wave Plus Lifeline

Association group 1 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1 Linked to BASIC
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_APPLICATION_STATUS_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V7
COMMAND_CLASS_THERMOSTAT_MODE_V1
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V1
COMMAND_CLASS_THERMOSTAT_SETPOINT_V1
COMMAND_CLASS_THERMOSTAT_FAN_MODE_V1
COMMAND_CLASS_THERMOSTAT_FAN_STATE_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V4
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_PROTECTION_V2
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_CLOCK_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_SECURITY_V1