layout | title |
---|---|
documentation |
LZW31-SN - ZWave |
{% include base.html %}
This describes the Z-Wave device LZW31-SN, manufactured by Inovelli with the thing type UID of inovelli_lzw31sn_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The LZW31-SN supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Inovelli’s new dimmer switch is packed with features and designed with your house in mind.
From a hardware side we’ve upgraded our Z-Wave module for better distance and there is no longer a need for a neutral wire. The switch can be used in any 3-Way or 4-Way setting and allows you to use either an auxiliary switch, a smart switch or your existing dumb switch (NOTE: this only applies if a neutral wire is installed. If there is no neutral wire, the switch only works in a single-pole setting).
From a firmware side, this switch has it all (literally). Scene control, notifications (flashes if your garage door is left open) and can be configured on any HUB.
Once the inclusion process has started press the config button 3X and the LED bar will flash blue. If the switch was included successfully the bar will turn GREEN, however if the switch was not included successfully it will turn RED.
Press the Config Button 3X
Important: If you have a neutral wire, set parameter 21 correctly. If setting the switch up in a 3-way configuration, set parameter 22 (you may need to enable advanced settings to see this).
The following table summarises the channels available for the LZW31-SN -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Dimmer | switch_dimmer | switch_dimmer | DimmableLight | Dimmer |
Electric meter (watts) | meter_watts | meter_watts | Energy | Number |
Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number |
Reset Meter | meter_reset | meter_reset | Energy | Switch |
Scene Number | scene_number | scene_number | Number | |
LED Strip Effect | config_decimal | config_decimal | Number | |
Default Level (Local) | config_decimal | config_decimal | Number | |
LED Indicator Color | config_decimal | config_decimal | Number | |
LED Indicator Intensity | config_decimal | config_decimal | Number | |
Auto Off Timer (Seconds) | config_decimal | config_decimal | Number | |
Protection Local | protection_local | protection_local | Number |
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer
channel is of type switch_dimmer
and supports the Dimmer
item and is in the DimmableLight
category.
Indicates the instantaneous power consumption.
The meter_watts
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Reset the meter.
The meter_reset
channel is of type meter_reset
and supports the Switch
item and is in the Energy
category.
Triggers when a scene button is pressed.
The scene_number
channel is of type scene_number
and supports the Number
item.
This channel provides the scene, and the event as a decimal value in the form <scene>.<event>
. The scene number is set by the device, and the event is as follows -:
Event ID | Event Description |
---|---|
0 | Single key press |
1 | Key released |
2 | Key held down |
3 | Double keypress |
4 | Tripple keypress |
5 | 4 x keypress |
6 | 5 x keypress |
Generic class for configuration parameter.
The config_decimal
channel is of type config_decimal
and supports the Number
item.
Generic class for configuration parameter.
The config_decimal
channel is of type config_decimal
and supports the Number
item.
Generic class for configuration parameter.
The config_decimal
channel is of type config_decimal
and supports the Number
item.
Generic class for configuration parameter.
The config_decimal
channel is of type config_decimal
and supports the Number
item.
Auto off timer in seconds. 0 to disable, max 32767
Generic class for configuration parameter.
The config_decimal
channel is of type config_decimal
and supports the Number
item.
Sets the local protection mode.
The protection_local
channel is of type protection_local
and supports the Number
item.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Unprotected |
1 | Protection by sequence |
2 | No operation possible |
The following table provides a summary of the 25 configuration parameters available in the LZW31-SN. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Dimming Speed (Z-Wave) | Dimming Speed (Z-Wave) |
2 | Dimming Speed (from switch) | Dimming Speed (from switch) |
3 | Ramp Rate (Z-Wave) | Ramp Rate (Z-Wave) |
4 | Ramp Rate (from switch) | Ramp Rate (from switch) |
5 | Minimum Dim Level | Minimum Dim Level |
6 | Maximum Dim Level | Maximum Dim Level |
7 | Invert Switch | Invert Switch |
8 | Auto Off Timer | Auto Off Timer |
9 | Default Level (Local) | Default Level (Local) |
10 | Default Level (Z-Wave) | Default Level (Z-Wave) |
11 | Power On State | Power On State |
12 | Association Behavior | Association Behavior |
13 | LED Indicator Color | LED Indicator Color |
14 | LED Indicator Intensity | LED Indicator Intensity |
15 | LED Indicator Intensity (When Off) | LED Indicator Intensity (When Off) |
16 | LED Strip Effect | LED Strip Effect |
17 | LED Indicator Timeout | LED Indicator Timeout |
18 | Active Power Reports | Active Power Reports |
19 | Periodic Power & Energy Reports | Periodic Power & Energy Reports |
20 | Energy Reports | Energy Reports |
21 | AC Power Type | AC Power Type |
22 | Switch Type | Switch Type |
50 | Multi-Tap Delay | Multi-Tap Delay |
51 | Instant On | Instant On |
52 | Enable "smart bulb" mode | Enable "smart bulb" mode |
Dimming Speed (Z-Wave)
Values in the range 0 to 100 may be set.
The manufacturer defined default value is 3
.
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Dimming Speed (from switch)
Values in the range 0 to 101 may be set.
The manufacturer defined default value is 101
.
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Ramp Rate (Z-Wave)
Values in the range 0 to 101 may be set.
The manufacturer defined default value is 101
.
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Ramp Rate (from switch)
Values in the range 0 to 101 may be set.
The manufacturer defined default value is 101
.
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Minimum Dim Level
Values in the range 1 to 45 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Maximum Dim Level
Values in the range 55 to 99 may be set.
The manufacturer defined default value is 99
.
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
Invert Switch Inverts the switch (Tap Down = On, Tap Up = Off) The following option values may be configured, in addition to values in the range 0 to 1 -:
Value | Description |
---|---|
0 | Disabled |
1 | Enabled |
The manufacturer defined default value is 0
(Disabled).
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
Auto Off Timer Automatically turns the switch off after x amount of seconds. Values in the range 0 to 32767 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_8_2
and is of type INTEGER
.
Default Level (Local)
Values in the range 0 to 99 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_9_1
and is of type INTEGER
.
Default Level (Z-Wave)
Values in the range 0 to 99 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_10_1
and is of type INTEGER
.
Power On State When power is restored, the switch reverts to either On, Off or Last Level.
0=Off, 1-99=Specific % On, 101=Returns to level before Power Outage. Values in the range 0 to 101 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_11_1
and is of type INTEGER
.
Association Behavior When should the switch send commands to the associated devices:
01 = Local, 02 = 3-Way, 03 = 3-Way & Local, 04 = Z-Wave Hub, 05 = Z-Wave Hub & Local, 06 = Z-Wave Hub & 3-Way, 07 = Z-Wave Hub & Local & 3-Way, 08 = Timer, 09 = Timer & Local, 10 = Timer & 3-Way, 11 =Timer & 3-Way & Local, 12 = Timer & Z-Wave Hub, 13 = Timer & Z-Wave Hub & Local, 14 = Timer & Z-Wave Hub & 3-Way, 15 = All Values in the range 0 to 15 may be set.
The manufacturer defined default value is 15
.
This parameter has the configuration ID config_12_1
and is of type INTEGER
.
LED Indicator Color
Values in the range 0 to 255 may be set.
The manufacturer defined default value is 170
.
This parameter has the configuration ID config_13_2
and is of type INTEGER
.
LED Indicator Intensity This will set the intensity of the LED bar (ie: how bright it is) in 10% increments. Values in the range 0 to 10 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_14_1
and is of type INTEGER
.
LED Indicator Intensity (When Off) This is the intensity of the LED bar when the switch is off in 10% increments. Values in the range 0 to 10 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_15_1
and is of type INTEGER
.
LED Strip Effect Addition: To get the final code for the desired color/effect/duration, use this calculator: https://nathanfiscus.github.io/inovelli-notification-calc/This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 100600575 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_16_4
and is of type INTEGER
.
LED Indicator Timeout Changes the amount of time the RGB Bar shows the Dim level if the LED Bar has been disabled. Values in the range 0 to 10 may be set.
The manufacturer defined default value is 3
.
This parameter has the configuration ID config_17_1
and is of type INTEGER
.
Active Power Reports
Values in the range 0 to 100 may be set.
The manufacturer defined default value is 10
.
This parameter has the configuration ID config_18_1
and is of type INTEGER
.
Periodic Power & Energy Reports
Values in the range 0 to 32767 may be set.
The manufacturer defined default value is 3600
.
This parameter has the configuration ID config_19_2
and is of type INTEGER
.
Energy Reports
Values in the range 0 to 100 may be set.
The manufacturer defined default value is 10
.
This parameter has the configuration ID config_20_1
and is of type INTEGER
.
AC Power Type Select whether you are wiring your switch with or without a neutral wire. (0=No-Neutral, 1=Neutral) The following option values may be configured, in addition to values in the range 0 to 1 -:
Value | Description |
---|---|
0 | No-Neutral |
1 | Neutral |
The manufacturer defined default value is 1
(Neutral).
This parameter has the configuration ID config_21_1
and is of type INTEGER
.
Switch Type Select what type of installation you have (0=single-pole, 1=3-Way w/dumb switch, 2=3-Way w/aux switch) The following option values may be configured, in addition to values in the range 0 to 2 -:
Value | Description |
---|---|
0 | Single-Pole (One Switch) |
1 | Multi-Switch (Dumb Switch) |
2 | Multi-Switch (Auxiliary Switch) |
The manufacturer defined default value is 0
(Single-Pole (One Switch)).
This parameter has the configuration ID config_22_1
and is of type INTEGER
.
Multi-Tap Delay Adjust the delay when parameter 51 is set to 1. 1=100ms, 2=200ms, 3=300ms, etc. The following option values may be configured, in addition to values in the range 1 to 9 -:
Value | Description |
---|---|
1 | 100ms |
2 | 200ms |
3 | 300ms |
4 | 400ms |
5 | 500ms |
6 | 600ms |
7 | 700ms |
8 | 800ms |
9 | 900ms |
The manufacturer defined default value is 7
(700ms).
This parameter has the configuration ID config_50_1
and is of type INTEGER
.
Instant On Enable instant on (ie: disable 700ms delay at the switch). If delay is disabled, scene control will be limited to button 1 (ie: tap up 1x or tap down 1x) and button 7 (config button). All other buttons (2-6) will be disabled. The following option values may be configured, in addition to values in the range 0 to 1 -:
Value | Description |
---|---|
0 | No delay |
1 | 700ms delay |
The manufacturer defined default value is 1
(700ms delay).
This parameter has the configuration ID config_51_1
and is of type INTEGER
.
Enable "smart bulb" mode Smart bulb mode: If set to 1, power will output maximum % when dimmer is on to optimize performance with smart bulbs. The following option values may be configured, in addition to values in the range 0 to 1 -:
Value | Description |
---|---|
0 | normal bulb |
1 | smart bulb |
The manufacturer defined default value is 0
(normal bulb).
This parameter has the configuration ID config_52_1
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The LZW31-SN supports 4 association groups.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Members of this group will receive unsolicited messages related to the status of the switch.
Association group 1 supports 5 nodes.
Single press UP button sends BasicSet (0xFF) and single press Down sends BasicSet (0x00)
Association group 2 supports 5 nodes.
Sends dim/brighten commands to associated device when switch is pressed.
Association group 3 supports 5 nodes.
Sends start and stop level changes to associated devices.
Association group 4 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_APPLICATION_STATUS_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V2 | Linked to BASIC |
COMMAND_CLASS_METER_V3 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_CENTRAL_SCENE_V3 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_PROTECTION_V2 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_SECURITY_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.