layout | title |
---|---|
documentation |
SmartPower - ZWave |
{% include base.html %}
This describes the Z-Wave device SmartPower, manufactured by INNOVUS with the thing type UID of innovus_smartpower_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The SmartPower supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
For the further reduction of energy consumption INNOVUS offers "RAone SmartPower". This module is an on / off module, which is used in particular to reduce the energy consumption of devices that unnecessarily consume power in "stand-by mode". This module also has a fingertip panel and is also equipped with an internal power meter.
The device is put into learn mode by touching the touchplate.
The device is put into learn mode by touching the touchplate.
The following table summarises the channels available for the SmartPower -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Sensor (power) | sensor_power | sensor_power | Energy | Number |
Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number |
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Indicates the energy consumption (kWh).
The sensor_power
channel is of type sensor_power
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
The following table provides a summary of the 2 configuration parameters available in the SmartPower. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Report node | Report changes in level to this node id |
2 | BO IR support | Enable/Disable BO IR Support |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Report changes in level to this node id Report Node, reports changes in level to this node id.
Disabled if 0. -> Copied from SmartDimmer, as there's no config information available. Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Enable/Disable BO IR Support BO IR support is disabled if 0 otherwise enabled. -> Copied from SmartDimmer, as there's no config information available. The following option values may be configured -:
Value | Description |
---|---|
0 | Disabled |
1 | Enabled |
The manufacturer defined default value is 1
(enabled).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The SmartPower supports 1 association group.
Association group 1 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_SWITCH_TOGGLE_BINARY_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V2 | |
COMMAND_CLASS_METER_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_PROTECTION_V1 | |
COMMAND_CLASS_NODE_NAMING_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.