layout | title |
---|---|
documentation |
ID-150 - ZWave |
{% include base.html %}
This describes the Z-Wave device ID-150, manufactured by ID Lock AS with the thing type UID of idlock_idl150new_01_006
.
This version of the device is limited to firmware versions above 1.6
The device is in the category of Lock, defining Devices whose primary pupose is locking something.
The ID Lock Z-wave module is a security enabled Z-wave Plus product that is able to use encrypted Z-wave Plus messages in order to communicate to other Z-wave Plus products enabled security.
The module is proprietary for the ID Lock 150 and also backwards compatible with the ID Lock 101. The ID Lock Z-wave module must be used in conjunction with a Security Enabled Z-wave Controller in order to fully utilize their full capability.
The ID Lock Z-wave module can be included and operated in any Z-wave network containing certified other Z-wave products regardless of manufacturer. The ID Lock Z-wave module does not support the Basic Set Command Class.
- Bring the controller as close as possible to the lock unit
- Set the controller to inclusion mode
- Push and hold KEY button on the inside panel on the lock until all keys on the outside light up and a audible signal is given.
- Release the KEY button on the inside panel
- Enter your Master PIN and press *
- Click 2 and then *
- Click 5, don't press *
- The LED flashes blue when inclusion is in progress
- The inclusion may take some time as security is required
- Set the controller to Exclusion mode
- Push and hold KEY button on the inside panel on the lock until all keys on the outside light up and a audible signal is given.
- Release the KEY button on the inside panel
- Enter your Master PIN and press *
- Click 2 and then *
- Click 5, don't press *
- The LED flashes blue when exclusion is in progress
The following table summarises the channels available for the ID-150 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Door Lock | lock_door | lock_door | Door | Switch |
Door State | sensor_door | sensor_door | Door | Contact |
Access control | notification_access_control | notification_access_control | Number | |
Emergency (Contact Fire Service) [Deprecated] | alarm_emergency | alarm_emergency | Alarm | Switch |
Burglar alarm (tampering) | alarm_burglar | alarm_burglar | Door | Switch |
Alarm (raw) [Deprecated] | alarm_raw | alarm_raw | String | |
Battery Level | battery-level | system.battery_level | Battery | Number |
Lock and unlock the door.
The lock_door
channel is of type lock_door
and supports the Switch
item and is in the Door
category.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Locked |
OFF | Unlocked |
Indicates if the door/window is open or closed.
The sensor_door
channel is of type sensor_door
and supports the Contact
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Contact
item type -:
Value | Label |
---|---|
OPEN | Open |
CLOSED | Closed |
Access Control.
The notification_access_control
channel is of type notification_access_control
and supports the Number
item. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Previous Events cleared |
1 | Manual Lock Operation |
2 | Manual Unlock Operation |
3 | RF Lock Operation |
4 | RF Unlock Operation |
5 | Keypad Lock Operation |
6 | Keypad Unlock Operation |
7 | Manual Not Fully Locked Operation |
8 | RF Not Fully Locked Operation |
9 | Auto Lock Locked Operation |
10 | Auto Lock Not Fully Operation |
11 | LockJammed |
12 | All user codes deleted |
13 | Single user code deleted |
14 | New user code added |
15 | New user code not added due to duplicate code |
16 | Keypad temporary disabled |
17 | Keypad busy |
18 | New Program code Entered- Unique code for lock configuration |
19 | Manually Enter user Access code exceeds code limit |
20 | Unlock by RF with invalid user code |
21 | Locked by RF with invalid user code |
22 | Window/Door is open |
23 | Window/Door is closed |
64 | Barrier performing initialization process |
65 | Barrier operation (Open / Close) force has been exceeded |
66 | Barrier motor has exceeded manufacturer's operational time limit |
67 | Barrier operation has exceeded physical mechanical limits |
68 | Barrier unable to perform requested operation due to UL requirements |
69 | Barrier Unattended operation has been disabled per UL requirements |
70 | Barrier failed to perform Requested operation, device malfunction |
71 | Barrier Vacation Mode |
72 | Barrier Safety Beam Obstacle |
73 | Barrier Sensor Not Detected / Supervisory Error |
74 | Barrier Sensor Low Battery Warning |
75 | Barrier detected short in WallStation wires |
76 | Barrier associated with non-Z-wave remote control |
2: Contact Fire Service
Indicates Police, Fire, or Medical services should be contacted.
The alarm_emergency
channel is of type alarm_emergency
and supports the Switch
item and is in the Alarm
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | EMERGENCY |
OFF | OK |
Note: This channel is marked as deprecated so should not be used.
3: Tampering (case opened)
Indicates if the burglar alarm is triggered.
The alarm_burglar
channel is of type alarm_burglar
and supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Provides alarm parameters as json string.
The alarm_raw
channel is of type alarm_raw
and supports the String
item. This is a read only channel so will only be updated following state changes from the device.
This channel sets, and provides the alarm state as a JSON string. It is designed for use in rules.
Note: This channel is marked as deprecated so should not be used.
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The system.battery-level
channel is of type system.battery-level
and supports the Number
item and is in the Battery
category.
This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.
The following table provides a summary of the 7 configuration parameters available in the ID-150. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Door lock mode | Set if the lock is in away mode and if automatic locking should be enabled |
2 | RFID Mode | RFID Mode |
3 | Door Hinge Position Mode | Tell the lock which side your hinges are on seen from the outside |
4 | Door Audio Volume Level | Set the Audio Volume Level of the Lock |
5 | Door ReLock Mode | Sets if the door should relock or not |
6 | Service PIN Mode | Sets the validity of the service PIN |
7 | Door Lock Model Type | Sends information if the model of the lock is 101 or 150 |
Lock Timeout | Sets the time after which the door will auto lock |
Set if the lock is in away mode and if automatic locking should be enabled Auto lock Mode, Manual lock mode, Activate Away Mode, Deactivate Away Mode.
If value is 0x02 (Enable Away, Manual lock) and the door is unlocked value will be set to 0x00.
If value is 0x03 (Enable Away, Auto lock) and the door is unlocked value will be set to 0x01.
Default Value: 1 (Disable Away/Auto Lock Mode) The following option values may be configured -:
Value | Description |
---|---|
0 | Disable Away Manual Lock |
1 | Disable Away Auto Lock |
2 | Enable Away Manual Lock |
3 | Enable Away Auto Lock |
The manufacturer defined default value is 1
(Disable Away Auto Lock).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
RFID Mode
The following option values may be configured -:
Value | Description |
---|---|
5 | RFID activated |
9 | RFID deactivated |
The manufacturer defined default value is 5
(RFID activated).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Tell the lock which side your hinges are on seen from the outside
The following option values may be configured -:
Value | Description |
---|---|
0 | Right hinged operation |
1 | Left hinged operation |
The manufacturer defined default value is 0
(Right hinged operation).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Set the Audio Volume Level of the Lock
The following option values may be configured -:
Value | Description |
---|---|
0 | No sound |
1 | Level 1 |
2 | Level 2 |
3 | Level 3 |
4 | Level 4 |
5 | Level 5 (Default) |
6 | Max. sound level |
The manufacturer defined default value is 5
(Level 5 (Default)).
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Sets if the door should relock or not With this configuration ID Lock can automatically relock the door if an already locked door gets unlocked, but remains unopened. This is avoided by deactivating relocking. The following option values may be configured -:
Value | Description |
---|---|
0 | Disabled |
1 | Enabled |
The manufacturer defined default value is 1
(Enabled).
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Sets the validity of the service PIN A configuration get command on this parameter returns the latest set parameter value (set by Z-wave).
This is a set only value, if changed locally on keypad these values are not changed on Z-wave module. Value 5 and 6 are for future use on door lock. The following option values may be configured -:
Value | Description |
---|---|
0 | Deactivated |
1 | Valid 1 time |
2 | Valid 2 times |
3 | Valid 5 times |
4 | Valid 10 times |
7 | Always Valid |
8 | Valid for 12h |
9 | Valid for 24h |
254 | Disabled |
The manufacturer defined default value is 0
(Deactivated).
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
Sends information if the model of the lock is 101 or 150 This configuration is only accepted by configuration get command
It is a read only parameter. Default value depends on the door lock model type.
101 = ID Lock 101
150 = ID Lock 150 Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
This is a read only parameter.
Sets the time after which the door will auto lock.
This parameter has the configuration ID doorlock_timeout
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ID-150 supports 1 association group.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Notification Reports are sent out unsolicated to device included in the association group.
Association group 1 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_DOOR_LOCK_V2 | |
COMMAND_CLASS_USER_CODE_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V4 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_SECURITY_V1 |
- Firmware Release Notes
- ID Lock 150 installation and user manual
- ID Lock 150 Z wave manual
- ZWave user manual v3.02 (FW 1.6)
- Firmware Release Notes 2020
- Firmware Release Notes 2020
- Z-wave module (FW 1.6) user manual
- Firmware Release Notes 2020 (delete the other ones with same name)
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.