ID-150 Z wave module for ID Lock 150

This describes the Z-Wave device ID-150, manufactured by ID Lock AS with the thing type UID of idlock_idl150new_01_006. This version of the device is limited to firmware versions above 1.6

The device is in the category of Lock, defining Devices whose primary pupose is locking something.

ID-150 product image

Overview

The ID Lock Z-wave module is a security enabled Z-wave Plus product that is able to use encrypted Z-wave Plus messages in order to communicate to other Z-wave Plus products enabled security.

The module is proprietary for the ID Lock 150 and also backwards compatible with the ID Lock 101. The ID Lock Z-wave module must be used in conjunction with a Security Enabled Z-wave Controller in order to fully utilize their full capability.

The ID Lock Z-wave module can be included and operated in any Z-wave network containing certified other Z-wave products regardless of manufacturer. The ID Lock Z-wave module does not support the Basic Set Command Class.

Inclusion Information

  1. Bring the controller as close as possible to the lock unit
  2. Set the controller to inclusion mode
  3. Push and hold KEY button on the inside panel on the lock until all keys on the outside light up and a audible signal is given.
  4. Release the KEY button on the inside panel
  5. Enter your Master PIN and press * 
  6. Click 2 and then *
  7. Click 5, don't press *
  8. The LED flashes blue when inclusion is in progress
  9. The inclusion may take some time as security is required

Exclusion Information

  1. Set the controller to Exclusion mode
  2. Push and hold KEY button on the inside panel on the lock until all keys on the outside light up and a audible signal is given.
  3. Release the KEY button on the inside panel
  4. Enter your Master PIN and press * 
  5. Click 2 and then *
  6. Click 5, don't press *
  7. The LED flashes blue when exclusion is in progress

General Usage Information

Channels

The following table summarises the channels available for the ID-150 -:

Channel Name Channel ID Channel Type Category Item Type
Door Lock lock_door lock_door Door Switch
Door State sensor_door sensor_door Door Contact
Access control notification_access_control notification_access_control Number
Emergency (Contact Fire Service) [Deprecated] alarm_emergency alarm_emergency Alarm Switch
Burglar alarm (tampering) alarm_burglar alarm_burglar Door Switch
Alarm (raw) [Deprecated] alarm_raw alarm_raw String
Battery Level battery-level system.battery_level Battery Number

Door Lock

Lock and unlock the door.

The lock_door channel is of type lock_door and supports the Switch item and is in the Door category. The following state translation is provided for this channel to the Switch item type -:

Value Label
ON Locked
OFF Unlocked

Door State

Indicates if the door/window is open or closed.

The sensor_door channel is of type sensor_door and supports the Contact item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Contact item type -:

Value Label
OPEN Open
CLOSED Closed

Access control

Access Control.

The notification_access_control channel is of type notification_access_control and supports the Number item. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Number item type -:

Value Label
0 Previous Events cleared
1 Manual Lock Operation
2 Manual Unlock Operation
3 RF Lock Operation
4 RF Unlock Operation
5 Keypad Lock Operation
6 Keypad Unlock Operation
7 Manual Not Fully Locked Operation
8 RF Not Fully Locked Operation
9 Auto Lock Locked Operation
10 Auto Lock Not Fully Operation
11 LockJammed
12 All user codes deleted
13 Single user code deleted
14 New user code added
15 New user code not added due to duplicate code
16 Keypad temporary disabled
17 Keypad busy
18 New Program code Entered- Unique code for lock configuration
19 Manually Enter user Access code exceeds code limit
20 Unlock by RF with invalid user code
21 Locked by RF with invalid user code
22 Window/Door is open
23 Window/Door is closed
64 Barrier performing initialization process
65 Barrier operation (Open / Close) force has been exceeded
66 Barrier motor has exceeded manufacturer's operational time limit
67 Barrier operation has exceeded physical mechanical limits
68 Barrier unable to perform requested operation due to UL requirements
69 Barrier Unattended operation has been disabled per UL requirements
70 Barrier failed to perform Requested operation, device malfunction
71 Barrier Vacation Mode
72 Barrier Safety Beam Obstacle
73 Barrier Sensor Not Detected / Supervisory Error
74 Barrier Sensor Low Battery Warning
75 Barrier detected short in WallStation wires
76 Barrier associated with non-Z-wave remote control

Emergency (Contact Fire Service) [Deprecated]

2: Contact Fire Service

Indicates Police, Fire, or Medical services should be contacted.

The alarm_emergency channel is of type alarm_emergency and supports the Switch item and is in the Alarm category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
ON EMERGENCY
OFF OK

Note: This channel is marked as deprecated so should not be used.

Burglar alarm (tampering)

3: Tampering (case opened)

Indicates if the burglar alarm is triggered.

The alarm_burglar channel is of type alarm_burglar and supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Alarm (raw) [Deprecated]

Provides alarm parameters as json string.

The alarm_raw channel is of type alarm_raw and supports the String item. This is a read only channel so will only be updated following state changes from the device. This channel sets, and provides the alarm state as a JSON string. It is designed for use in rules. Note: This channel is marked as deprecated so should not be used.

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The system.battery-level channel is of type system.battery-level and supports the Number item and is in the Battery category. This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.

Device Configuration

The following table provides a summary of the 7 configuration parameters available in the ID-150. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Door lock mode Set if the lock is in away mode and if automatic locking should be enabled
2 RFID Mode RFID Mode
3 Door Hinge Position Mode Tell the lock which side your hinges are on seen from the outside
4 Door Audio Volume Level Set the Audio Volume Level of the Lock
5 Door ReLock Mode Sets if the door should relock or not
6 Service PIN Mode Sets the validity of the service PIN
7 Door Lock Model Type Sends information if the model of the lock is 101 or 150
Lock Timeout Sets the time after which the door will auto lock

Parameter 1: Door lock mode

Set if the lock is in away mode and if automatic locking should be enabled Auto lock Mode, Manual lock mode, Activate Away Mode, Deactivate Away Mode.

If value is 0x02 (Enable Away, Manual lock) and the door is unlocked value will be set to 0x00.

If value is 0x03 (Enable Away, Auto lock) and the door is unlocked value will be set to 0x01.

 Default Value: 1 (Disable Away/Auto Lock Mode) The following option values may be configured -:

Value Description
0 Disable Away Manual Lock
1 Disable Away Auto Lock
2 Enable Away Manual Lock
3 Enable Away Auto Lock

The manufacturer defined default value is 1 (Disable Away Auto Lock).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: RFID Mode

RFID Mode

The following option values may be configured -:

Value Description
5 RFID activated
9 RFID deactivated

The manufacturer defined default value is 5 (RFID activated).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Door Hinge Position Mode

Tell the lock which side your hinges are on seen from the outside

The following option values may be configured -:

Value Description
0 Right hinged operation
1 Left hinged operation

The manufacturer defined default value is 0 (Right hinged operation).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Door Audio Volume Level

Set the Audio Volume Level of the Lock

The following option values may be configured -:

Value Description
0 No sound
1 Level 1
2 Level 2
3 Level 3
4 Level 4
5 Level 5 (Default)
6 Max. sound level

The manufacturer defined default value is 5 (Level 5 (Default)).

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Door ReLock Mode

Sets if the door should relock or not With this configuration ID Lock can automatically relock the door if an already locked door gets unlocked, but remains unopened. This is avoided by deactivating relocking. The following option values may be configured -:

Value Description
0 Disabled
1 Enabled

The manufacturer defined default value is 1 (Enabled).

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 6: Service PIN Mode

Sets the validity of the service PIN A configuration get command on this parameter returns the latest set parameter value (set by Z-wave).

This is a set only value, if changed locally on keypad these values are not changed on Z-wave module. Value 5 and 6 are for future use on door lock. The following option values may be configured -:

Value Description
0 Deactivated
1 Valid 1 time
2 Valid 2 times
3 Valid 5 times
4 Valid 10 times
7 Always Valid
8 Valid for 12h
9 Valid for 24h
254 Disabled

The manufacturer defined default value is 0 (Deactivated).

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Parameter 7: Door Lock Model Type

Sends information if the model of the lock is 101 or 150 This configuration is only accepted by configuration get command

It is a read only parameter. Default value depends on the door lock model type.

101 = ID Lock 101

150 = ID Lock 150 Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_7_1 and is of type INTEGER. This is a read only parameter.

Lock Timeout

Sets the time after which the door will auto lock.

This parameter has the configuration ID doorlock_timeout and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The ID-150 supports 1 association group.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Notification Reports are sent out unsolicated to device included in the association group.

Association group 1 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_DOOR_LOCK_V2
COMMAND_CLASS_USER_CODE_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V4
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_SECURITY_V1

Documentation Links