layout | title |
---|---|
documentation |
C17-ZW - ZWave |
{% include base.html %}
This describes the Z-Wave device C17-ZW, manufactured by Horstmann Controls Limited with the thing type UID of horstmann_c17zw_00_000
.
The device is in the category of HVAC, defining Air condition devices, Fans.
The C17-ZW supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
The CentaurPlus ZW is a timeswitch which is connected to its own room thermostat - the HRT4-ZW - using the latest Z-wave wireless technology.
Where it has been used to replace your existing time control it is likely that there was no room thermostat fitted previously
For inclusion, put the controller in inclusion mode and press and hold the 'Boost' and 'Enter' buttons on the front of the CENTAURPLUS C17-ZW . Once included the indicator next to the radio symbol will appear (solid)
For exclusion put the controller in exclusion mode and Press and hold the 'Boost' and 'Enter' buttons on the front of the CENTAURPLUS C17-ZW until an indicator disappears in its display against the radio aerial symbol
The following table summarises the channels available for the C17-ZW -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
The device has no configuration parameters defined.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The device does not support associations.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_APPLICATION_STATUS_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_VERSION_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.