layout title
documentation
39351 / Jasco ZW3005 - ZWave

{% include base.html %}

39351 / Jasco ZW3005 In-Wall Smart Dimmer

This describes the Z-Wave device 39351 / Jasco ZW3005, manufactured by Honeywell with the thing type UID of honeywell_39351_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

39351 / Jasco ZW3005 product image

The 39351 / Jasco ZW3005 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

  • Indoor
  • Dimmer Switch
  • 120 VAC, 60 Hz
  • 908.42/916 MHz
  • Max Incandescent Load 1-gang 600W
  • Max Incandescent Load 2-gang 500W
  • Max Incandescent Load 3-gang 400W
  • Max CFL/LED Load 150W
  • Max Range 45 m
  • Operating Temperature Range 0°C to 40°C
  • UL Listed
  • FCC ID U2ZZW3005A
  • IC 6924A-ZW3005A

Inclusion Information

Press and release the top or bottom of the dimmer (rocker).  (Tested to work with Network Wide Inclusion.)

Exclusion Information

Press and release the top or bottom of the dimmer (rocker).

General Usage Information

Appears to be the same device as the GE 14294 / Jasco ZW3005.

Channels

The following table summarises the channels available for the 39351 / Jasco ZW3005 -:

Channel Name Channel ID Channel Type Category Item Type
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer
Scene Number scene_number scene_number Number

Dimmer

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel is of type switch_dimmer and supports the Dimmer item and is in the DimmableLight category.

Scene Number

Triggers when a scene button is pressed.

The scene_number channel is of type scene_number and supports the Number item.

Device Configuration

The following table provides a summary of the 2 configuration parameters available in the 39351 / Jasco ZW3005. Detailed information on each parameter can be found in the sections below.

Param Name Description
3 LED Light LED status when device on or off.
4 Invert Switch Switch orientation.
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 3: LED Light

LED status when device on or off.

The following option values may be configured -:

Value Description
0 LED ON when load is OFF
1 LED ON when load is ON
2 LED always OFF

The manufacturer defined default value is 0 (LED ON when load is OFF).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Invert Switch

Switch orientation.

The following option values may be configured -:

Value Description
0 Default
1 Invert Switch

The manufacturer defined default value is 0 (Default).

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The 39351 / Jasco ZW3005 supports 3 association groups.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Z-Wave Plus Lifeline, Multilevel Switch Report

Association group 1 supports 5 nodes.

Group 2: Basic Set Local Load

Support Basic Set and is controlled with the local load

Association group 2 supports 5 nodes.

Group 3: Basic Set Double Press

Supports Basic Set and is controlled by double pressing the On or Off button

Association group 3 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V2 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_SCENE_ACTIVATION_V1
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1
COMMAND_CLASS_CRC_16_ENCAP_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2

Documentation Links