layout | title |
---|---|
documentation |
39351 / Jasco ZW3005 - ZWave |
{% include base.html %}
This describes the Z-Wave device 39351 / Jasco ZW3005, manufactured by Honeywell with the thing type UID of honeywell_39351_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The 39351 / Jasco ZW3005 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
- Indoor
- Dimmer Switch
- 120 VAC, 60 Hz
- 908.42/916 MHz
- Max Incandescent Load 1-gang 600W
- Max Incandescent Load 2-gang 500W
- Max Incandescent Load 3-gang 400W
- Max CFL/LED Load 150W
- Max Range 45 m
- Operating Temperature Range 0°C to 40°C
- UL Listed
- FCC ID U2ZZW3005A
- IC 6924A-ZW3005A
Press and release the top or bottom of the dimmer (rocker). (Tested to work with Network Wide Inclusion.)
Press and release the top or bottom of the dimmer (rocker).
Appears to be the same device as the GE 14294 / Jasco ZW3005.
The following table summarises the channels available for the 39351 / Jasco ZW3005 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Dimmer | switch_dimmer | switch_dimmer | DimmableLight | Dimmer |
Scene Number | scene_number | scene_number | Number |
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer
channel is of type switch_dimmer
and supports the Dimmer
item and is in the DimmableLight
category.
Triggers when a scene button is pressed.
The scene_number
channel is of type scene_number
and supports the Number
item.
The following table provides a summary of the 2 configuration parameters available in the 39351 / Jasco ZW3005. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
3 | LED Light | LED status when device on or off. |
4 | Invert Switch | Switch orientation. |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
LED status when device on or off.
The following option values may be configured -:
Value | Description |
---|---|
0 | LED ON when load is OFF |
1 | LED ON when load is ON |
2 | LED always OFF |
The manufacturer defined default value is 0
(LED ON when load is OFF).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Switch orientation.
The following option values may be configured -:
Value | Description |
---|---|
0 | Default |
1 | Invert Switch |
The manufacturer defined default value is 0
(Default).
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The 39351 / Jasco ZW3005 supports 3 association groups.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Z-Wave Plus Lifeline, Multilevel Switch Report
Association group 1 supports 5 nodes.
Support Basic Set and is controlled with the local load
Association group 2 supports 5 nodes.
Supports Basic Set and is controlled by double pressing the On or Off button
Association group 3 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V2 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_SCENE_ACTIVATION_V1 | |
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1 | |
COMMAND_CLASS_CRC_16_ENCAP_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 |