ZW4106 / GE39342 - ZWave

{% include base.html %}

ZW4106 / GE39342 Plug-In Smart Switch (Dual Linked Outlets, Grounded)

This describes the Z-Wave device ZW4106 / GE39342, manufactured by Honeywell with the thing type UID of honeywell_39342_00_000.

The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.

ZW4106 / GE39342 product image

The ZW4106 / GE39342 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

  • 2 Simultaneously Controlled Outlets
  • Only Blocks One Outlet / Cords Exit Sideways
  • Indoor
  • Wall Plug
  • 120 VAC, 60 Hz
  • 908.42/916 MHz
  • Max Incandescent Load 600W (5A)
  • Max Resistive Load 1800W (15A)
  • Max Motor 1/2 HP
  • Max Range 45 m
  • Operating Temperature Range 0°C to 40°C
  • UL Listed
  • FCC ID U2ZZW4104
  • IC 6924A-ZW4104

Inclusion Information

Press and release the manual/program button.  (Tested to work with Network Wide Inclusion.)

Exclusion Information

Press and release the manual/program button.

General Usage Information

Appears to be the same device as the GE 14282 / Jasco ZW4106.

Channels

The following table summarises the channels available for the ZW4106 / GE39342 -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch
Scene Number scene_number scene_number Number

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Scene Number

Triggers when a scene button is pressed.

The scene_number channel is of type scene_number and supports the Number item.

Device Configuration

The following table provides a summary of the 1 configuration parameters available in the ZW4106 / GE39342. Detailed information on each parameter can be found in the sections below.

Param Name Description
3 LED Light Control Controls LED light state
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 3: LED Light Control

Controls LED light state

The following option values may be configured -:

Value Description
0 LED Light on when switch turned OFF (Default)
1 LED Light on when switch turned On
2 LED Light Always Off

The manufacturer defined default value is 0 (LED Light on when switch turned OFF (Default)).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The ZW4106 / GE39342 supports 3 association groups.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.

Association group 1 supports 5 nodes.

Group 2: Group 1

Basic Set controlled with local load

Association group 2 supports 5 nodes.

Group 3: Group 2

Basic Set controlled by double pressing button

Association group 3 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_SCENE_ACTIVATION_V1
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1
COMMAND_CLASS_CRC_16_ENCAP_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2

Documentation Links