HS1HT-Z Temperature/Humidity Sensor

This describes the Z-Wave device *HS1HT-Z *, manufactured by Heiman Technology Co. Ltd with the thing type UID of heiman_hs1htz_00_000.

The device is in the category of Sensor, defining Device used to measure something.

HS1HT-Z  product image

The HS1HT-Z supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

The HS1HT-Z does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.

Overview

Smart Temperature and Humidity Sensor is designed to detect the temperature and humidity in house, and reports the abnormal conditions to users' mobile phone, Users could also check the real-time temperature and humidity via mobile phone, The sensor adopts Z-Wave wireless communication protocol with high sensitivity.

See:
https://products.z-wavealliance.org/products/2321 and http://www.heimantech.com/product/80.html

Inclusion Information

Click [Add] icon in Z-Wave Controller.

  • Press the Net_Button 3 times within 1.5s, Green LED is Blinking 3 times within 1 second.
  • If Inclusion Process is successful, Green LED will turn off.

Exclusion Information

Click [Remove] icon in Z-Wave Controller.

  • Press the Net_Button 3 times within 1.5s
  • If Exclusion Process is successful, Green LED is Blinking 6 times, then turn off

Wakeup Information

The HS1HT-Z does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.

The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.

  Wake up Notification is transmitted every 24 hours by default.

-  Wake up Notification is transmitted after Notification Report is Transmitted

Channels

The following table summarises the channels available for the HS1HT-Z -:

Channel Name Channel ID Channel Type Category Item Type
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number:Temperature
Sensor (relative humidity) sensor_relhumidity sensor_relhumidity Humidity Number
Battery Level battery-level system.battery_level Battery Number

Sensor (temperature)

Indicates the current temperature.

The sensor_temperature channel is of type sensor_temperature and supports the Number:Temperature item and is in the Temperature category.

Sensor (relative humidity)

Indicates the current relative humidity.

The sensor_relhumidity channel is of type sensor_relhumidity and supports the Number item and is in the Humidity category. This is a read only channel so will only be updated following state changes from the device.

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The system.battery-level channel is of type system.battery-level and supports the Number item and is in the Battery category. This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.

Device Configuration

The device has no configuration parameters defined.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The HS1HT-Z supports 3 association groups.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Association group 1: Lifeline association group Maximum supported node is 1. Include command classes: Battery report, multilevel sensor report, and Device Reset Locally.

Association group 1 supports 1 node.

Group 2: Multilevel sensor temperature

Association group 2: Root Device group(multilevel sensor temperature) Maximum supported nodes are 5. 1- multilevel Sensor reports status of the temperature via Lifeline. 2-When the sensor detects status of the temperature, the device will be triggered.

Association group 2 supports 5 nodes.

Group 3: Multilevel sensor humidity

Association group 3: Root Device group(multilevel sensor humidity) Maximum supported nodes are 5. 1-multilevel Sensor reports status of the humidity via Lifeline. 2-When the sensor detects status of the humidity , the device will be triggered.

Association group 3 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V10 Linked to BASIC
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.