This describes the Z-Wave device GWPN6, manufactured by GreenWave Reality Inc. with the thing type UID of greenwave_gwpn6_00_000
.
The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.
The GWPN6 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
This Configuration is for the 6 plug version of the PowerNode.
It should work for both NP210 and NP310 devices (except NP210-G-EN which is 5-port UK version).
On the PowerNode, press and hold the Sync button for approximately one second until the activity indicator displays a clockwise rotating pattern. This indicates the PowerNode is attempting inclusion. During this process, verify that the Gateway activity indicator still displays a clockwise rotating pattern.
After a few seconds, the rotating pattern on both the PowerNode and the Gateway stops. All bars turn green forming a circle for several seconds. This indicates a successful inclusion.
If all bars on the activity indicator start flashing instead of forming a solid circle, then the PowerNode inclusion process has failed, and you must start the sync process again. If syncing continually fails even though the PowerNode is close to the Gateway, then it may be an indication of a hardware fault, and the PowerNode might need replacing.
On the PowerNode, press and hold the Sync button for approximately one second until the PowerNode activity indicator begins to display a counter-clockwise rotating pattern. The PowerNode is attempting exclusion.
The following table summarises the channels available for the GWPN6 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Electric meter (watts) | meter_watts | meter_watts | Energy | Number |
Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number |
Alarm | alarm_general | alarm_general | Alarm | Switch |
Switch 1 | switch_binary1 | switch_binary | Switch | Switch |
Electric meter (watts) 1 | meter_watts1 | meter_watts | Energy | Number |
Electric meter (kWh) 1 | meter_kwh1 | meter_kwh | Energy | Number |
Switch 2 | switch_binary2 | switch_binary | Switch | Switch |
Electric meter (watts) 2 | meter_watts2 | meter_watts | Energy | Number |
Electric meter (kWh) 2 | meter_kwh2 | meter_kwh | Energy | Number |
Switch 3 | switch_binary3 | switch_binary | Switch | Switch |
Electric meter (watts) 3 | meter_watts3 | meter_watts | Energy | Number |
Electric meter (kWh) 3 | meter_kwh3 | meter_kwh | Energy | Number |
Switch 4 | switch_binary4 | switch_binary | Switch | Switch |
Electric meter (watts) 4 | meter_watts4 | meter_watts | Energy | Number |
Electric meter (kWh) 4 | meter_kwh4 | meter_kwh | Energy | Number |
Switch 5 | switch_binary5 | switch_binary | Switch | Switch |
Electric meter (watts) 5 | meter_watts5 | meter_watts | Energy | Number |
Electric meter (kWh) 5 | meter_kwh5 | meter_kwh | Energy | Number |
Switch 6 | switch_binary6 | switch_binary | Switch | Switch |
Electric meter (watts) 6 | meter_watts6 | meter_watts | Energy | Number |
Electric meter (kWh) 6 | meter_kwh6 | meter_kwh | Energy | Number |
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Indicates the instantaneous power consumption.
The meter_watts
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates if an alarm is triggered.
The alarm_general
channel is of type alarm_general
and supports the Switch
item and is in the Alarm
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Switch the power on and off.
The switch_binary1
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Indicates the instantaneous power consumption.
The meter_watts1
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh1
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Switch the power on and off.
The switch_binary2
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Indicates the instantaneous power consumption.
The meter_watts2
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh2
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Switch the power on and off.
The switch_binary3
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Indicates the instantaneous power consumption.
The meter_watts3
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh3
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Switch the power on and off.
The switch_binary4
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Indicates the instantaneous power consumption.
The meter_watts4
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh4
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Switch the power on and off.
The switch_binary5
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Indicates the instantaneous power consumption.
The meter_watts5
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh5
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Switch the power on and off.
The switch_binary6
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Indicates the instantaneous power consumption.
The meter_watts6
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh6
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
The following table provides a summary of the 5 configuration parameters available in the GWPN6. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
0 | Min. variation of load current | Minimum variation in load current before a message is sent. |
1 | No communication light | Duration (min) the device flashes after a communication error. |
2 | Wheel position | Wheel position on the GreenWave device (read-only) |
3 | Power-on state | Default state after power loss |
4 | LED for network error | If the LED should indicate a network error by flashing or not |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Minimum variation in load current before a message is sent. Minimum variation in load current before a message is sent. Value in percent (30 => 30%) Values in the range 0 to 100 may be set.
The manufacturer defined default value is 10
.
This parameter has the configuration ID config_0_1
and is of type INTEGER
.
Duration (min) the device flashes after a communication error. After how many minutes the GreenWave device should start flashing if the controller didn't communicate with this device. Values in the range 0 to 255 may be set.
The manufacturer defined default value is 2
.
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Wheel position on the GreenWave device (read-only)
The following option values may be configured -:
Value | Description |
---|---|
128 | Black |
129 | Green |
130 | Dark Blue |
131 | Red |
132 | Yellow |
133 | Purple |
134 | Orange |
135 | Light Blue |
136 | Pink |
137 | Locked |
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
This is a read only parameter.
Default state after power loss
The following option values may be configured -:
Value | Description |
---|---|
0 | All OFF |
1 | Remember last state |
2 | All ON |
The manufacturer defined default value is 2
(All ON).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
If the LED should indicate a network error by flashing or not
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable the LED for network error |
1 | Enable the LED for network error |
The manufacturer defined default value is 1
(Enable the LED for network error).
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The GWPN6 supports 4 association groups.
Association group 1 supports 1 node.
Association group 2 supports 1 node.
The new power reading is sent if the delta of the change is greater than the defined minimum variation.
Association group 3 supports 1 node.
Association group 4 supports 1 node.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_METER_V2 | |
COMMAND_CLASS_CRC_16_ENCAP_V1 | |
COMMAND_CLASS_MULTI_CHANNEL_V2 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_METER_V2 |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_METER_V2 |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_METER_V2 |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_METER_V2 |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_METER_V2 |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_METER_V2 |