This describes the Z-Wave device ZW4006 / GE26931, manufactured by Jasco Products with the thing type UID of ge_zw4006_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

ZW4006 / GE26931 product image

The ZW4006 / GE26931 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

The switch enables wireless control of On/OFF functions of incandescent, LED, xenon, halogen and fluorescent lighting. Not only does it act as a switch but the GE In-Wall Smart Motion Switch has a built in PIR sensor which can control the local and be set in occupancy or vacancy mode.

Inclusion Information

  1. Follow the instructions for your Z-Wave certified controller to include the smart switch to the Z-Wave network.
  2. Once the controller is ready to include your smart switch, press and release the top or bottom button on the smart switch to include it in the network. 

Exclusion Information

  1. Follow the instructions for your Z-Wave certified controller to exclude a device from the Z-Wave network.
  2. Once the controller is ready to exclude your device, press and release the top or bottom button on the smart switch to exclude it from the network. 

General Usage Information

Channels

The following table summarises the channels available for the ZW4006 / GE26931 -:

Channel Name Channel ID Channel Type Category Item Type
Switch [Deprecated] switch_binary switch_binary Switch Switch
Scene Number scene_number scene_number Number
Binary Sensor sensor_binary sensor_binary Switch
Motion Sensor Enable config_decimal config_decimal Number
Operation Mode config_decimal config_decimal Number
Motion Alarm [Deprecated] alarm_motion alarm_motion Motion Switch
Switch 1 switch_binary1 switch_binary Switch Switch
Motion Alarm alarm_motion2 alarm_motion Motion Switch

Switch [Deprecated]

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Note: This channel is marked as deprecated so should not be used.

Scene Number

Triggers when a scene button is pressed.

The scene_number channel is of type scene_number and supports the Number item.

Binary Sensor

Indicates if a sensor has triggered.

The sensor_binary channel is of type sensor_binary and supports the Switch item. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
ON Triggered
OFF Untriggered

Motion Sensor Enable

Generic class for configuration parameter.

The config_decimal channel is of type config_decimal and supports the Number item.

Operation Mode

Sets how the light responds to motion

1=Manual, 2=Vacancy, 3=Occupancy

Generic class for configuration parameter.

The config_decimal channel is of type config_decimal and supports the Number item.

Motion Alarm [Deprecated]

Indicates if a motion alarm is triggered.

The alarm_motion channel is of type alarm_motion and supports the Switch item and is in the Motion category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Note: This channel is marked as deprecated so should not be used.

Switch 1

Switch the power on and off.

The switch_binary1 channel is of type switch_binary and supports the Switch item and is in the Switch category.

Motion Alarm

Indicates if a motion alarm is triggered.

The alarm_motion2 channel is of type alarm_motion and supports the Switch item and is in the Motion category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Device Configuration

The following table provides a summary of the 10 configuration parameters available in the ZW4006 / GE26931. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Timeout Duration Amount of time the light stays on after motion stops
2 Dim level Change brightness of associated light bulb(s)
3 Operation Mode
4 Association Mode Enable/Disable Association Mode
5 Invert Switch In a 3-way configuration, invert the connected Add-On Switch buttons
6 Motion Sensor Enable/Disable Motion Sensor
13 Motion Sensor Sensitivity Amount of motion required to turn on the light
14 Light Sensing Enable/Disable whether motion sensor only turns light on if room is dark
15 Reset Cycle
19 Exclusion Mode
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: Timeout Duration

Amount of time the light stays on after motion stops

The following option values may be configured -:

Value Description
0 Test (5s)
1 One minute
5 Five minutes
15 Fifteen minutes
30 Thirty minutes
255 Disable timeout

The manufacturer defined default value is 5 (Five minutes).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Dim level

Change brightness of associated light bulb(s)

The following option values may be configured -:

Value Description
255 Default

The manufacturer defined default value is 255 (Default).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Operation Mode

The following option values may be configured -:

Value Description
1 Manual
2 Vacancy
3 Occupancy

The manufacturer defined default value is 3 (Occupancy).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Association Mode

Enable/Disable Association Mode

The following option values may be configured -:

Value Description
0 Disabled
1 Enabled

The manufacturer defined default value is 1 (Enabled).

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Invert Switch

In a 3-way configuration, invert the connected Add-On Switch buttons

The following option values may be configured -:

Value Description
0 Disabled
1 Enabled

The manufacturer defined default value is 0 (Disabled).

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 6: Motion Sensor

Enable/Disable Motion Sensor

The following option values may be configured -:

Value Description
0 Disabled
1 Enabled

The manufacturer defined default value is 1 (Enabled).

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Parameter 13: Motion Sensor Sensitivity

Amount of motion required to turn on the light

The following option values may be configured -:

Value Description
1 High
2 Medium
3 Low

The manufacturer defined default value is 2 (Medium).

This parameter has the configuration ID config_13_1 and is of type INTEGER.

Parameter 14: Light Sensing

Enable/Disable whether motion sensor only turns light on if room is dark

The following option values may be configured -:

Value Description
0 Disabled
1 Enabled

The manufacturer defined default value is 1 (Enabled).

This parameter has the configuration ID config_14_1 and is of type INTEGER.

Parameter 15: Reset Cycle

The following option values may be configured -:

Value Description
0 Disable
1 10 secs
2 20 secs
3 30 secs
4 45 secs
110 27 mins

The manufacturer defined default value is 2 (20 secs).

This parameter has the configuration ID config_15_1 and is of type INTEGER.

Parameter 19: Exclusion Mode

The following option values may be configured -:

Value Description
0 Normal
1 Alternate

The manufacturer defined default value is 0 (Normal).

This parameter has the configuration ID config_19_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The ZW4006 / GE26931 supports 3 association groups.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Z-Wave Plus Lifeline

Association group 1 supports 5 nodes.

Group 2: Basic Set Local Load

Supports Basic Set and is controlled with the local load

Association group 2 supports 5 nodes.

Group 3: Basic Set Buttons

Supports Basic Set and is controlled by pressing the On or Off buttons

Association group 3 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_SCENE_ACTIVATION_V1
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1
COMMAND_CLASS_SENSOR_BINARY_V1
COMMAND_CLASS_CRC_16_ENCAP_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_MULTI_CHANNEL_V2
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V4
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3

Endpoint 1

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1

Endpoint 2

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_ALARM_V4 Linked to BASIC

Documentation Links