Skip to content

Latest commit

 

History

History
executable file
·
132 lines (84 loc) · 4.46 KB

45609_0_0.md

File metadata and controls

executable file
·
132 lines (84 loc) · 4.46 KB
layout title
documentation
45609 - ZWave

{% include base.html %}

45609 On/Off Relay Switch

This describes the Z-Wave device 45609, manufactured by Jasco Products with the thing type UID of ge_45609_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

45609 product image

The 45609 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

Wall mounted On/Off switch. Control the On/Off status of permanently installed lighting, fans and more!

Inclusion Information

When prompted by your primary controller, tap the top or bottom of the rocker

Exclusion Information

Once the controller is ready to Exclude your device, press and release the top or bottom of the wireless smart switch (rocker) to exclude it from the network

Channels

The following table summarises the channels available for the 45609 -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Device Configuration

The following table provides a summary of the 2 configuration parameters available in the 45609. Detailed information on each parameter can be found in the sections below.

Param Name Description
3 Night Light Defines the behavior of the blue LED.
4 Invert Switch Change the top of the switch to OFF and the bottom of the switch to ON.
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 3: Night Light

Defines the behavior of the blue LED. Default is Night Light mode where LED is on when switch is off. The following option values may be configured -:

Value Description
0 LED on when switch is OFF
1 LED on when switch is ON
2 LED always off

The manufacturer defined default value is 0 (LED on when switch is OFF).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Invert Switch

Change the top of the switch to OFF and the bottom of the switch to ON. Note: If you invert the switches and also install the product upside down, remember the load will now be controlled by the right, not the left switch. The following option values may be configured -:

Value Description
0 No
1 Yes

The manufacturer defined default value is 0 (No).

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The device does not support associations.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_NODE_NAMING_V1
COMMAND_CLASS_VERSION_V1

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.