layout | title |
---|---|
documentation |
WV-01 - ZWave |
{% include base.html %}
This describes the Z-Wave device WV-01, manufactured by FortrezZ LLC with the thing type UID of fortrezz_wv01_00_000
.
The device is in the category of Valve, defining Valves used to control water or gas. e.g. a flow stop valve..
The WV-01 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Fortrezz WV-01 Wireless Z-Wave Water Valve is a patented, wireless water detection and automatic water shut-off system that works as an automatic valve for your home's main water supply line and can easily be installed by a certified professional plumber.
When used in a Z-Wave home automation network, the smart valve can be used along with Z-Wave water alarm sensors to reduce or eliminate water damage caused by leaky pipes or faulty appliances. It can also be used in conjunction with remotely installed flood sensors to shut off the main water supply in case of water leakage.
Put controller into inclusion mode, then press the Program button once.
Put controller into exclusion mode, then press the Program button once.
The following table summarises the channels available for the WV-01 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Alarm | alarm_general | alarm_general | Alarm | Switch |
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Indicates if an alarm is triggered.
The alarm_general
channel is of type alarm_general
and supports the Switch
item and is in the Alarm
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
The following table provides a summary of the 2 configuration parameters available in the WV-01. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
0 | Mode | |
1 | WaterLevel Timeout |
The following option values may be configured -:
Value | Description |
---|---|
0 | Alarm Mode |
255 | Level Mode |
The manufacturer defined default value is 0
(Alarm Mode).
This parameter has the configuration ID config_0_1
and is of type INTEGER
.
Values in the range 1 to 32767 may be set.
The manufacturer defined default value is 60
.
This parameter has the configuration ID config_1_2
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The device does not support associations.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_APPLICATION_STATUS_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_VERSION_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.