layout | title |
---|---|
documentation |
ZWS12n - ZWave |
{% include base.html %}
This describes the Z-Wave device ZWS12n, manufactured by Fakro with the thing type UID of fakro_zws12n_00_000
.
The device is in the category of Window, defining Window.
The ZWS12n supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
FAKRO ZWS12 chain motor thanks to their small dimensions and suitable force output are ideal for roof window operating, being fully compatible with the Z-Wave Plus system. The motors can be applied in both centre pivot and top hung and pivot roof windows as well as windows of non-standard dimensions.
The chain has 2 output speed and reach 24cm.
The ZWS12 motor is equipped with encoder and two limit switches:
limit switch at maximum chain travel position, overload limit in both directions (used mainly when closing the window).
This product can be operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers.
ZWS12 also can be **controlled manually **by button and closed by rain sensor and timer.
Z-Wave Plus Secure Enabled Product
This device is a security enabled Z-Wave Plus product that is able to use encrypted Z-Wave Plus messages to communicate to other security enabled Z-Wave Plus products.
Technical Parameters:
- Chain reach: 240 mm
- Output power : 9 W
- Rated current: 0.72 A
- Standby current: 0.03 A
- Chain pushing force: 200 N
- Closing force: 200 N
- Current limit: YES
- Power voltage: 15V DC
- Power cable: 2 x 0.75 mm2 (0,4 m)
Reset:
Device Reset Locally – This function allows you to reset the Z-Wave network without the use of Z-Wave controller. Press 5 times the programming button P fast, the actuator was removed from the Z-Wave network, restore the default parameters, name and locations.
Please use this procedure only when the network primary controller is missing or otherwise inoperable.
Autoinclusion - This feature allow you to add hard to reach devices to Z-Wave network. 3-times ON and OFF the power actuator (OFF-ON-OFFON-OFF-ON) causes the introduction of actuator to Autoinclusion mode.
Please note that the procedure has been started the time between on and off can not exceed 20s. Autoinclusion mode is activated for a maximum of 10 minutes. During this time, we can add an actuator to any Z-Wave controller running in the Include procedure.
Include - This function allow you to add actuator to the network Z-Wave.
Follow the procedure adding device to the network Z-Wave according to user manual supplied with the product. Then, press the programming button P on the actuator for 1 second.
Exclude - This function allow you to remove actuator from the network Z-Wave. Follow the procedure removing device from the network Z-Wave according to user manual supplied with the product. Then, press the programming button P on the actuator for 1 second. Function removes information only about network Z-Wave.
The following table summarises the channels available for the ZWS12n -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Blinds Control | blinds_control | blinds_control | Blinds | Rollershutter |
Alarm (power) | alarm_power | alarm_power | Energy | Switch |
Alarm (flood) | alarm_flood | alarm_flood | Water | Switch |
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Provides start / stop control of blinds.
The blinds_control
channel is of type blinds_control
and supports the Rollershutter
item and is in the Blinds
category.
Indicates if a power alarm is triggered.
The alarm_power
channel is of type alarm_power
and supports the Switch
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Indicates if the flood alarm is triggered.
The alarm_flood
channel is of type alarm_flood
and supports the Switch
item and is in the Water
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
The following table provides a summary of the 6 configuration parameters available in the ZWS12n. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
7 | Motor speed I | Motor speed I |
7 | Motor speed I | Motor speed I |
8 | 1 Motor speed II (rain sensor) | 1 Motor speed II (rain sensor) |
12 | Callibrate | This parameter on/off callibration function |
13 | Last saved position | Set servomotor in previous position |
15 | Close after time | Close after time min |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Motor speed I 1- the lowest speed
2- default
4 - the higest speed Values in the range 1 to 4 may be set.
The manufacturer defined default value is 2
.
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
Motor speed I 1- the lowest speed
2- default
4 - the higest speed Values in the range 1 to 4 may be set.
The manufacturer defined default value is 2
.
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
1 Motor speed II (rain sensor) 1- the lowest speed
2- default
4 - the higest speed Values in the range 1 to 4 may be set.
The manufacturer defined default value is 2
.
This parameter has the configuration ID config_8_1
and is of type INTEGER
.
This parameter on/off callibration function Value 1 – calibrated
Value 2 – discalibrated
to enter the calibration mode must first time discalibrate and then calibrate.
Calibration possible after prior recalibration of the device. It is possible via gate (Gateway Z-Wave), remote control with a display, e.g. ZRS24 remote control (FAKRO).
See manual. Values in the range 1 to 2 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_12_1
and is of type INTEGER
.
Set servomotor in previous position This parameter set servomotor in previous position after using Basic Mode operation.
1 – FF go to Max
2 – FF go to previous position Values in the range 1 to 2 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_13_1
and is of type INTEGER
.
Close after time min 0-120 minutes Values in the range 0 to 120 may be set.
The manufacturer defined default value is 120
.
This parameter has the configuration ID config_15_1
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZWS12n supports 4 association groups.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Position reporting Life Line – group for position reporting actuator after each a stoppage and alarm reporting (overcurrent, damage encoders). This group can be a maximum 1 device.
Association group 1 supports 1 node.
Basic commands Basic Repeat – group used to transfer the received basic commands to the devices included in this group. This group can be a maximum 5 devices.
Association group 2 supports 5 nodes.
Transfer the received multilevel commands Multilevel Repeat – group used to transfer the received multilevel commands to the devices included in this group. This group can be a maximum 5 devices.
Association group 3 supports 5 nodes.
Transfer the received commands from actuator & rain detector to the devices Basic Rain – group used to transfer the received commands from actuator & rain detector to the devices included in this group. This group can be a maximum 5 devices.
Association group 4 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V3 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V3 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_NODE_NAMING_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.