ZWS12n - ZWave

{% include base.html %}

ZWS12n Chain actuator - window opener

This describes the Z-Wave device ZWS12n, manufactured by Fakro with the thing type UID of fakro_zws12n_00_000.

The device is in the category of Window, defining Window.

ZWS12n product image

The ZWS12n supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

FAKRO ZWS12 chain motor thanks to their small dimensions and suitable force output are ideal for roof window operating, being fully compatible with the Z-Wave Plus system. The motors can be applied in both centre pivot and top hung and pivot roof windows as well as windows of non-standard dimensions. 

The chain has 2 output speed and reach 24cm. 

The ZWS12 motor is equipped with encoder and two limit switches:

limit switch at maximum chain travel position, overload limit in both directions (used mainly when closing the window).

This product can be operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers.

ZWS12 also can be **controlled manually **by button and closed by rain sensor and timer.

Z-Wave Plus Secure Enabled Product

This device is a security enabled Z-Wave Plus product that is able to use encrypted Z-Wave Plus messages to communicate to other security enabled Z-Wave Plus products.

Technical Parameters: 

  • Chain reach: 240 mm
  • Output power : 9 W
  • Rated current: 0.72 A
  • Standby current: 0.03 A
  • Chain pushing force: 200 N
  • Closing force: 200 N
  • Current limit: YES
  • Power voltage: 15V DC
  • Power cable: 2 x 0.75 mm2 (0,4 m)

Reset:

Device Reset Locally – This function allows you to reset the Z-Wave network without the use of Z-Wave controller. Press 5 times the programming button P fast, the actuator was removed from the Z-Wave network, restore the default parameters, name and locations.

Please use this procedure only when the network primary controller is missing or otherwise inoperable.

Inclusion Information

Autoinclusion - This feature allow you to add hard to reach devices to Z-Wave network. 3-times ON and OFF the power actuator (OFF-ON-OFFON-OFF-ON) causes the introduction of actuator to Autoinclusion mode.

Please note that the procedure has been started the time between on and off can not exceed 20s. Autoinclusion mode is activated for a maximum of 10 minutes. During this time, we can add an actuator to any Z-Wave controller running in the Include procedure.

Include - This function allow you to add actuator to the network Z-Wave.

Follow the procedure adding device to the network Z-Wave according to user manual supplied with the product. Then, press the programming button P on the actuator for 1 second.

Exclusion Information

Exclude - This function allow you to remove actuator from the network Z-Wave. Follow the procedure removing device from the network Z-Wave according to user manual supplied with the product. Then, press the programming button P on the actuator for 1 second. Function removes information only about network Z-Wave.

Channels

The following table summarises the channels available for the ZWS12n -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch
Blinds Control blinds_control blinds_control Blinds Rollershutter
Alarm (power) alarm_power alarm_power Energy Switch
Alarm (flood) alarm_flood alarm_flood Water Switch

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Blinds Control

Provides start / stop control of blinds.

The blinds_control channel is of type blinds_control and supports the Rollershutter item and is in the Blinds category.

Alarm (power)

Indicates if a power alarm is triggered.

The alarm_power channel is of type alarm_power and supports the Switch item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Alarm (flood)

Indicates if the flood alarm is triggered.

The alarm_flood channel is of type alarm_flood and supports the Switch item and is in the Water category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Device Configuration

The following table provides a summary of the 6 configuration parameters available in the ZWS12n. Detailed information on each parameter can be found in the sections below.

Param Name Description
7 Motor speed I Motor speed I
7 Motor speed I Motor speed I
8 1 Motor speed II (rain sensor) 1 Motor speed II (rain sensor)
12 Callibrate This parameter on/off callibration function
13 Last saved position Set servomotor in previous position
15 Close after time Close after time min
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 7: Motor speed I

Motor speed I 1- the lowest speed

2- default

4 - the higest speed Values in the range 1 to 4 may be set.

The manufacturer defined default value is 2.

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 7: Motor speed I

Motor speed I 1- the lowest speed

2- default

4 - the higest speed Values in the range 1 to 4 may be set.

The manufacturer defined default value is 2.

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 8: 1 Motor speed II (rain sensor)

1 Motor speed II (rain sensor) 1- the lowest speed

2- default

4 - the higest speed Values in the range 1 to 4 may be set.

The manufacturer defined default value is 2.

This parameter has the configuration ID config_8_1 and is of type INTEGER.

Parameter 12: Callibrate

This parameter on/off callibration function Value 1 – calibrated

Value 2 – discalibrated

to enter the calibration mode must first time discalibrate and then calibrate.

Calibration possible after prior recalibration of the device. It is possible via gate (Gateway Z-Wave), remote control with a display, e.g. ZRS24 remote control (FAKRO). 

See manual. Values in the range 1 to 2 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_12_1 and is of type INTEGER.

Parameter 13: Last saved position

Set servomotor in previous position This parameter set servomotor in previous position after using Basic Mode operation.

1 – FF go to Max

2 – FF go to previous position Values in the range 1 to 2 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_13_1 and is of type INTEGER.

Parameter 15: Close after time

Close after time min 0-120 minutes Values in the range 0 to 120 may be set.

The manufacturer defined default value is 120.

This parameter has the configuration ID config_15_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The ZWS12n supports 4 association groups.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Position reporting Life Line – group for position reporting actuator after each a stoppage and alarm reporting (overcurrent, damage encoders). This group can be a maximum 1 device.

Association group 1 supports 1 node.

Group 2: Basic Repeat

Basic commands Basic Repeat – group used to transfer the received basic commands to the devices included in this group. This group can be a maximum 5 devices.

Association group 2 supports 5 nodes.

Group 3: Multilevel Repeat

Transfer the received multilevel commands Multilevel Repeat – group used to transfer the received multilevel commands to the devices included in this group. This group can be a maximum 5 devices.

Association group 3 supports 5 nodes.

Group 4: Basic Rain

Transfer the received commands from actuator & rain detector to the devices Basic Rain – group used to transfer the received commands from actuator & rain detector to the devices included in this group. This group can be a maximum 5 devices.

Association group 4 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V3 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V3
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_NODE_NAMING_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.