Skip to content

Latest commit

 

History

History
executable file
·
106 lines (68 loc) · 3.99 KB

arf_0_0.md

File metadata and controls

executable file
·
106 lines (68 loc) · 3.99 KB
layout title
documentation
ARF - ZWave

{% include base.html %}

ARF Roller blind module

This describes the Z-Wave device ARF, manufactured by Fakro with the thing type UID of fakro_arf_00_000.

The device is in the category of Blinds, defining Roller shutters, window blinds, etc..

ARF product image

The ARF supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

The ARF blackout blind is a stylish, decorative blind with runners at the sides to allow the blind to be posi tioned anywhere on the window. It also prevents daylight entering at the sides, thus providing a complete blackout. 

The ARF Z-Wave blackout blind has a built in 12V electric drive which enables operation at 12V blinds by remote control or wall switch. The standard version of the action blinds ARF Z-Wave is only possible with the window closed. 

Inclusion Information

Start INCLUDE procedure with the controller of existing network and then press programming button P on the roller shutter being added to the network.

Exclusion Information

Start EXCLUDE procedure with the controller of existing network and then press programming button P on the roller shutter being added to the network.

Channels

The following table summarises the channels available for the ARF -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch
Blinds control blinds_control blinds_control Blinds Rollershutter
Alarm (power) alarm_power alarm_power Energy Switch

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Blinds control

Provides start / stop control of blinds.

The blinds_control channel is of type blinds_control and supports the Rollershutter item and is in the Blinds category.

Alarm (power)

Indicates if a power alarm is triggered.

The alarm_power channel is of type alarm_power and supports the Switch item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Device Configuration

The device has no configuration parameters defined.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The device does not support associations.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V3 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V3
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_NODE_NAMING_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2

Documentation Links