This describes the Z-Wave device LRM-AS, manufactured by Evolve with the thing type UID of evolve_lrmas_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

LRM-AS product image

The LRM-AS supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

Scene Capable Wall Switch DimmerThe LRM-AS Wall Mounted Dimmer is a component of the Evolve lighting control system. Inclusion of the LRM-AS Wall Mounted Dimmer allows remote ON/ OFF control and dimming of lights connected. 

Inclusion Information

Tap the button.

Exclusion Information

Tap the button 3 times, then press and hold (Ex. tap, tap, tap, hold)

Channels

The following table summarises the channels available for the LRM-AS -:

Channel Name Channel ID Channel Type Category Item Type
Switch [Deprecated] switch_binary switch_binary Switch Switch
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer
Binary Sensor sensor_binary sensor_binary Switch
Alarm alarm_general alarm_general Alarm Switch
Battery Level battery-level system.battery_level Battery Number

Switch [Deprecated]

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Note: This channel is marked as deprecated so should not be used.

Dimmer

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel is of type switch_dimmer and supports the Dimmer item and is in the DimmableLight category.

Binary Sensor

Indicates if a sensor has triggered.

The sensor_binary channel is of type sensor_binary and supports the Switch item. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
ON Triggered
OFF Untriggered

Alarm

Indicates if an alarm is triggered.

The alarm_general channel is of type alarm_general and supports the Switch item and is in the Alarm category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The system.battery-level channel is of type system.battery-level and supports the Number item and is in the Battery category. This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.

Device Configuration

The following table provides a summary of the 3 configuration parameters available in the LRM-AS. Detailed information on each parameter can be found in the sections below.

Param Name Description
3 Night Light In night-light mode the LED will turn ON when the switch is turned OFF.
4 Invert Switch Change the top of the switch to OFF and the bottom of the switch to ON.
29 Load Sense
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 3: Night Light

In night-light mode the LED will turn ON when the switch is turned OFF.

The following option values may be configured -:

Value Description
0 No
1 Yes

The manufacturer defined default value is 1 (Yes).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Invert Switch

Change the top of the switch to OFF and the bottom of the switch to ON.

The following option values may be configured -:

Value Description
0 No
1 Yes

The manufacturer defined default value is 0 (No).

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 29: Load Sense

The following option values may be configured -:

Value Description
0 Disable
1 Enable

The manufacturer defined default value is 0 (Disable).

This parameter has the configuration ID config_29_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The LRM-AS supports 1 association group.

Group 1: Group 1

Association group 1 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_APPLICATION_STATUS_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V1
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_SCENE_ACTIVATION_V1
COMMAND_CLASS_SENSOR_BINARY_V1
COMMAND_CLASS_METER_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1

Documentation Links