layout | title |
---|---|
documentation |
AN181 - ZWave |
{% include base.html %}
This describes the Z-Wave device AN181, manufactured by Everspring with the thing type UID of everspring_an181_00_000
.
The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.
The AN181 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
The Metering Plug is designed to control the on/off status appliances load in your house. For metering the unit can detect up to 10485.75kW*h and can support wattage, voltage, ampere, and PF detection. The unit can also detect overload upon which the unit will switch off relay and keep LED flashing until power is off and re-applied. At 220-240V voltage, this Plug can support up to 2500W resistive.
Press the link key three times within 1.5 seconds to put the unit into inclusion mode.
Press the link key three times within 1.5 seconds to put the unit into exclusion mode.
The following table summarises the channels available for the AN181 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number |
Electric meter (watts) | meter_watts | meter_watts | Energy | Number |
Electric meter (amps) | meter_current | meter_current | Energy | Number |
Electric meter (power factor) | meter_powerfactor | meter_powerfactor | Energy | Number |
Electric meter (volts) | meter_voltage | meter_voltage | Energy | Number |
Alarm | alarm_general | alarm_general | Alarm | Switch |
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Indicates the energy consumption (kWh).
The meter_kwh
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous current consumption.
The meter_current
channel is of type meter_current
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power factor.
The meter_powerfactor
channel is of type meter_powerfactor
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous voltage.
The meter_voltage
channel is of type meter_voltage
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates if an alarm is triggered.
The alarm_general
channel is of type alarm_general
and supports the Switch
item and is in the Alarm
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
The following table provides a summary of the 7 configuration parameters available in the AN181. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Command value | Set Basic Set Command value to be sent to group 2 when switch is turned on |
2 | Delaying time | Set the delaying time to report to Group 1 in seconds |
3 | Remember status | Set whether to remember the last status |
4 | Interval for wattage auto report | Set the interval for wattage auto report in minutes |
5 | Interval for kW*h auto report | Set the interval for kW*h auto report in minutes |
6 | Auto report load surpasses value | Auto report when load surpasses the set value of wattage |
7 | Auto report change percentage | Auto report when the change of wattage surpasses the set percentage |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Set Basic Set Command value to be sent to group 2 when switch is turned on Meaningful range is 0-99 & 255 where
0 = No command will be sent
1-99 = Turn on switches and dimmers listening to Group 2 to indicated % level (ON for switches)
255 = Turn on switches and dimmers (full power) listening to Group 2
Command will be sent if the mini plug is turned on via the button or if it receives a remote command.
Basic Set Command = 0 (Off) will be sent to Group 2 only if the button is used to turn off the mini plug, not when the mini plug is turned off via remote command. The following option values may be configured, in addition to values in the range 1 to 99 -:
Value | Description |
---|---|
0 | No Basic Set Command will be sent |
255 | Basic Set Command ON will be sent |
The manufacturer defined default value is 255
(Basic Set Command ON will be sent).
This parameter has the configuration ID config_1_2
and is of type INTEGER
.
Set the delaying time to report to Group 1 in seconds
Values in the range 3 to 25 may be set.
The manufacturer defined default value is 3
.
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Set whether to remember the last status
The following option values may be configured -:
Value | Description |
---|---|
0 | Do not remember |
1 | Remember |
The manufacturer defined default value is 1
(Remember).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Set the interval for wattage auto report in minutes
The following option values may be configured, in addition to values in the range 1 to 32767 -:
Value | Description |
---|---|
0 | Does not report automatically |
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_4_2
and is of type INTEGER
.
Set the interval for kW*h auto report in minutes
The following option values may be configured, in addition to values in the range 1 to 32767 -:
Value | Description |
---|---|
0 | Does not report automatically |
The manufacturer defined default value is 60
.
This parameter has the configuration ID config_5_2
and is of type INTEGER
.
Auto report when load surpasses the set value of wattage
The following option values may be configured, in addition to values in the range 1 to 2500 -:
Value | Description |
---|---|
0 | Does not report automatically |
The manufacturer defined default value is 0
(Does not report automatically).
This parameter has the configuration ID config_6_2
and is of type INTEGER
.
Auto report when the change of wattage surpasses the set percentage
The following option values may be configured, in addition to values in the range 1 to 100 -:
Value | Description |
---|---|
0 | Does not report automatically |
The manufacturer defined default value is 0
(Does not report automatically).
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The AN181 supports 2 association groups.
Binary Switch Report, Notification Report, Device Reset Locally Notification, Meter Report When powered on, the device will send (Notification Type = 0x08, Event = 0x01) to the node of Group 1. When overload occurs, the device will send (Notification Type = 0x08, Event = 0x08) to the node of Group 1.
Association group 1 supports 1 node.
Basic Set, Control:key1, On/Off control (Button1)
Association group 2 supports 4 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_APPLICATION_STATUS_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_METER_V3 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V3 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.