{% include base.html %}

HM-DW001 Door/Window Contact

This describes the Z-Wave device HM-DW001, manufactured by Erone with the thing type UID of erone_hmdw001_00_000.

The device is in the category of Door, defining Door sensors.

HM-DW001 product image

The HM-DW001 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

The HM-DW001 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.

Overview

The Door/Window Sensor is a Z-Wave® enabled device (interoperable, two-way RF mesh networking technology) and is fully compatible with any Z-Wave enabled network. Z-Wave enabled devices displaying the Z-Wave logo can also be used with it regardless of the manufacturer, and ours can also be used in other manufacturer’s Z-Wave enabled networks. Each mains powered module in a Network is designed to act as a repeater. Repeaters will retransmit the RF signal to ensure that the signal is received by its intended destination by routing the signal around obstacles and radio dead spots. 

Inclusion Information

In the rear casing, there is a tamper switch which is used to carry out inclusion, exclusion or association.

  • Put a Z-WAVETM Wireless Controller into inclusion/exclusion mode,
  • Press the tamper switch on the detector to complete the inclusion/exclusion process.

The Door/Window Detector will stay “awake” for ten minutes when changing the status of tamper switch from being pressed to be released or from being released to be pressed to allow time for configuration. 

Exclusion Information

In the rear casing, there is a tamper switch which is used to carry out inclusion, exclusion or association.

  • Put a Z-WAVETM Wireless Controller into inclusion/exclusion mode,
  • Press the tamper switch on the detector to complete the inclusion/exclusion process.

The Door/Window Detector will stay “awake” for ten minutes when changing the status of tamper switch from being pressed to be released or from being released to be pressed to allow time for configuration. 

Wakeup Information

The HM-DW001 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.

The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.

To wake up the device manually, triple-click the tamper button on the back of the device.

Channels

The following table summarises the channels available for the HM-DW001 -:

Channel Name Channel ID Channel Type Category Item Type
Binary Sensor sensor_binary sensor_binary Switch
Battery Level battery-level system.battery_level Battery Number

Binary Sensor

Indicates if a sensor has triggered.

The sensor_binary channel is of type sensor_binary and supports the Switch item. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
ON Triggered
OFF Untriggered

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The system.battery-level channel is of type system.battery-level and supports the Number item and is in the Battery category. This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.

Device Configuration

The following table provides a summary of the 2 configuration parameters available in the HM-DW001. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Basic Set Level Value to be sent with a BASIC SET command
2 Configuring the OFF Delay OFF Delay in seconds
Wakeup Interval Sets the interval at which the device will accept commands from the controller
Wakeup Node Sets the node ID of the device to receive the wakeup notifications

Parameter 1: Basic Set Level

Value to be sent with a BASIC SET command

Values in the range 0 to 99 may be set.

The manufacturer defined default value is 99.

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Configuring the OFF Delay

OFF Delay in seconds

Values in the range 0 to 127 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Wakeup Interval

The wakeup interval sets the period at which the device will listen for messages from the controller. This is required for battery devices that sleep most of the time in order to conserve battery life. The device will wake up at this interval and send a message to the controller to tell it that it can accept messages - after a few seconds, it will go back to sleep if there is no further communications.

This setting is defined in seconds. It is advisable not to set this interval too short or it could impact battery life. A period of 1 hour (3600 seconds) is suitable in most instances.

Note that this setting does not affect the devices ability to send sensor data, or notification events.

This parameter has the configuration ID wakeup_interval and is of type INTEGER.

Wakeup Node

When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address. In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.

This parameter has the configuration ID wakeup_node and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The HM-DW001 supports 2 association groups.

Group 1: Tamper Event Report (Alarm Report)

Association group 1 supports 5 nodes.

Group 2: Control other Z-Wave Devices

Association group 2 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SENSOR_BINARY_V1 Linked to BASIC
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_WAKE_UP_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1