Skip to content

Latest commit

 

History

History
executable file
·
234 lines (142 loc) · 9.39 KB

zw500dm_0_0.md

File metadata and controls

executable file
·
234 lines (142 loc) · 9.39 KB
layout title
documentation
ZW500DM - ZWave

{% include base.html %}

ZW500DM In-wall Smart Meter Dimmer Switch

This describes the Z-Wave device ZW500DM, manufactured by Wenzhou MTLC Electric Appliances Co.,Ltd. with the thing type UID of enerwave_zw500dm_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

ZW500DM product image

The ZW500DM supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

The ZW500DM Dimmer Switch is a perfect wireless manual and remote on/off/ dim brightness control replacement of regular switch, controlling incandescent, dimmable LED and CFL. This ZW500DM dimmer switch is fully compatible with other Z-Wave devices, provides programmable function creating a perfect ambiance such as scenes, association, schedule event, etc. Also it can be added to most Z-Wave compliant controllers.

Sliding Air-Gap switch to totally disconnect power while replacing light bulbs and preventing from leakage current from the fixture(s). This ZW500DM dimmer works with ZW3K 3-Way Auxiliary Switch that reduces energy consumption, enhancing the value of technology of your home, condominiums and apartment.

Features -:

  • Perfect Replacement for regular wall ON/OFF & Dim switch, 120VAC
  • Wireless Z-Wave technology creates a mesh network for command and control interoperability with other Z-Wave compliant controller and devices
  • Manual and Remote ON/OFF& Dim control of any permanently installed incandescent, dimmable LED and CFL lamp fixture
  • Preset light level option allows the dimmer will turn on to the light level that it was adjusted to the previous time when the light was on
  • Can be used for single pole or 3- Way (Multi-location) with ZW3K Auxiliary Switch (sold separately)
  • Measures energy usage of the wired load

The ZW500DM Smart Meter Dimmer Switch enables you to measure the energy usage of your appliance. When added to a Z-Wave network, the ZW500DM reports real time data to your gateway or controller. It can also display actual consumption (in W) and the accumulated power used (in kWh) in the user interface of the gateway/remote. Please use the gateway installation manual for specific instructions on measuring the power.

Inclusion Information

When the primary controller is in the adding mode, flicks the paddle 3 times in the 1.5 second. The primary controller will verify the adding, assign a node ID number for the module.

Exclusion Information

When the primary controller is in the removing mode, flicks the paddle 3 times in the 1.5 second. The primary controller will verify the removing, remove the module from the current Z-Wave network, and the LED will blink when the module is on power.

Channels

The following table summarises the channels available for the ZW500DM -:

Channel Name Channel ID Channel Type Category Item Type
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer
Sensor (power) sensor_power sensor_power Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number

Dimmer

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel is of type switch_dimmer and supports the Dimmer item and is in the DimmableLight category.

Sensor (power)

Indicates the energy consumption (kWh).

The sensor_power channel is of type sensor_power and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Device Configuration

The following table provides a summary of the 6 configuration parameters available in the ZW500DM. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 LED is on when load is on Synchronization of load power and LED indicator
8 Instant Energy Autosend Interval Instant Energy Autosend Interval (send METER_REPORT)
9 Instant Power Autosend Interval Instant Power Autosend interval (send SENSOR_MULTILEVEL_REPORT)
10 Accumulated Energy Autosend Interval Accumulated Energy Autosend Interval report (send METER_REPORT)
11 Enable automatic notifications Enable automatic notifications to associated device
12 Minimum change in wattage triggering report Minimum change in wattage report
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: LED is on when load is on

Synchronization of load power and LED indicator

The following option values may be configured -:

Value Description
0 Power on, LED off
1 Power on, LED on

The manufacturer defined default value is 0 (Power on, LED off).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 8: Instant Energy Autosend Interval

Instant Energy Autosend Interval (send METER_REPORT)

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_8_1 and is of type INTEGER.

Parameter 9: Instant Power Autosend Interval

Instant Power Autosend interval (send SENSOR_MULTILEVEL_REPORT)

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_9_1 and is of type INTEGER.

Parameter 10: Accumulated Energy Autosend Interval

Accumulated Energy Autosend Interval report (send METER_REPORT)

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_10_1 and is of type INTEGER.

Parameter 11: Enable automatic notifications

Enable automatic notifications to associated device Device will send a notification whenever the is a wattage change The following option values may be configured -:

Value Description
0 Not report (METER_REPORT)
1 Send (METER_REPORT) only
2 Send (SENSOR_MULTI_LEVEL_REPORT) only
3 Send both

The manufacturer defined default value is 1 (Send (METER_REPORT) only).

This parameter has the configuration ID config_11_1 and is of type INTEGER.

Parameter 12: Minimum change in wattage triggering report

Minimum change in wattage report 0-255: 0.0-25.5W Values in the range 0 to 255 may be set.

The manufacturer defined default value is 10.

This parameter has the configuration ID config_12_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The ZW500DM supports 3 association groups.

Group 1: Notifications

Lifeline

Association group 1 supports 1 node.

Group 2: StatusReport

Send basic report

Association group 2 supports 5 nodes.

Group 3: PowerReport

PowerReport: Send meter power report

Association group 3 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V2
COMMAND_CLASS_METER_V2
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.