This describes the Z-Wave device DMS01, manufactured by Elexa Consumer Products Inc. with the thing type UID of elexa_dms01_00_000.

The device is in the category of Siren, defining Siren used by Alarm systems.

DMS01 product image

The DMS01 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

Overview

Alert you with sounds and built-in LED’s to security threats and problems such as leaks and fires. It can also sound a mild chime when doors or windows open to let you know when people come and go.

Inclusion Information

Follow the instructions for your Z-Wave certified Controller to enter inclusion mode. When prompted by the Controller:

  1. For proper inclusion, bring the Siren to within 10 feet of your Controller. After inclusion, the device can be moved to any desired location.
  2. Remove the Back Plate of the Siren.
  3. Remove the Battery Tabs.
  4. Press the Connect Button quickly 3 times in a row. The LED Ring will flash five times indicating inclusion.

Exclusion Information

Follow the instructions for your Z-Wave certified Controller to enter exclusion mode. When prompted by the Controller:

  1. Remove the Back Plate of the Siren.
  2. Press the Connect Button quickly 3 times in a row. The LED Ring will flash five times indicating exclusion/disconnection.

Channels

The following table summarises the channels available for the DMS01 -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch
Notification Sound config_decimal config_decimal Number
Primary Notification Volume config_decimal config_decimal Number
Secondary Notification Volume config_decimal config_decimal Number
Primary Notification Sound config_decimal config_decimal Number
Secondary Notification Sound config_decimal config_decimal Number
Primary Notification Length config_decimal config_decimal Number
Secondary Notification Length config_decimal config_decimal Number
Alarm alarm_general alarm_general Alarm Switch
Battery Level battery-level system.battery_level Battery Number

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Notification Sound

Select the primary (1) and secondary (2) notification sounds. 

Generic class for configuration parameter.

The config_decimal channel is of type config_decimal and supports the Number item.

Primary Notification Volume

Primary notification volume: 1 (low), 2 (medium), 3 (high)

Generic class for configuration parameter.

The config_decimal channel is of type config_decimal and supports the Number item.

Secondary Notification Volume

Primary notification volume: 1 (low), 2 (medium), 3 (high)

Generic class for configuration parameter.

The config_decimal channel is of type config_decimal and supports the Number item.

Primary Notification Sound

Set the primary notification sound: 1 (ding dong), 2 (Fur Elise), 3 (Westminster Chime), 4 (Dingdongdingdongdingdong), 5 (William Tell Overture), 6 (Classical), 7 (Weeooeeooeeooeeoo), 8 (Err-err-err-err-err), 9 (Beepbeepbeepbeep), 10 (beeeep-beeeep-beeeep)

Generic class for configuration parameter.

The config_decimal channel is of type config_decimal and supports the Number item.

Secondary Notification Sound

Set the primary notification sound: 1 (ding dong), 2 (Fur Elise), 3 (Westminster Chime), 4 (Dingdongdingdongdingdong), 5 (William Tell Overture), 6 (Classical), 7 (Weeooeeooeeooeeoo), 8 (Err-err-err-err-err), 9 (Beepbeepbeepbeep), 10 (beeeep-beeeep-beeeep)

Generic class for configuration parameter.

The config_decimal channel is of type config_decimal and supports the Number item.

Primary Notification Length

Sets the primary notification length: 1 (30s), 2 (1m), 3 (5m), 255 (nonstop)

Generic class for configuration parameter.

The config_decimal channel is of type config_decimal and supports the Number item.

Secondary Notification Length

Set the secondary notification length: 0 (non-stop), 1 (1m), 5 (5m), 255 (does not play)

Generic class for configuration parameter.

The config_decimal channel is of type config_decimal and supports the Number item.

Alarm

Indicates if an alarm is triggered.

The alarm_general channel is of type alarm_general and supports the Switch item and is in the Alarm category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The system.battery-level channel is of type system.battery-level and supports the Number item and is in the Battery category. This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.

Device Configuration

The following table provides a summary of the 7 configuration parameters available in the DMS01. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Primary Notification Volume Level
2 Primary Notification Length
3 Secondary Notification Length
4 Secondary Notification Volume Level
5 Primary Notification Sound Set the siren primary notification sound.
6 Secondary Notification Sound
7 Toggle secondary chime Toggles between primary and secondary chime for binary switch

Parameter 1: Primary Notification Volume Level

The following option values may be configured -:

Value Description
1 Low Volume
2 Medium Volume
3 High Volume

The manufacturer defined default value is 2 (Medium Volume).

This parameter has the configuration ID config_1_2 and is of type INTEGER.

Parameter 2: Primary Notification Length

The following option values may be configured -:

Value Description
1 30 Seconds
2 1 Minute
3 5 Minutes
255 Plays Until Battery Is Depleted

The manufacturer defined default value is 2 (1 Minute).

This parameter has the configuration ID config_2_2 and is of type INTEGER.

Parameter 3: Secondary Notification Length

The following option values may be configured -:

Value Description
0 Does Not Stop
1 One Minute
5 Five Minutes
255 Chime Will Not Play

The manufacturer defined default value is 1 (One Minute).

This parameter has the configuration ID config_3_2 and is of type INTEGER.

Parameter 4: Secondary Notification Volume Level

The following option values may be configured -:

Value Description
1 Low Volume
2 Medium Volume
3 High Volume

The manufacturer defined default value is 2 (Medium Volume).

This parameter has the configuration ID config_4_2 and is of type INTEGER.

Parameter 5: Primary Notification Sound

Set the siren primary notification sound. The siren offers ten different sounds to use as the Siren (primary) notification. This parameter sets the Siren (primary) notification sound. The following option values may be configured -:

Value Description
1 Ding dong
2 Fur Elise
3 Westminster Chime
4 Dingdongdingdongdingdong
5 William Tell Overture
6 Classical
7 Weeooeeooeeooeeoo
8 Err-err-err-err-err
9 Beepbeepbeepbeep (Default)
10 beeeep-beeeep-beeeep

The manufacturer defined default value is 9 (Beepbeepbeepbeep (Default)).

This parameter has the configuration ID config_5_2 and is of type INTEGER.

Parameter 6: Secondary Notification Sound

The following option values may be configured -:

Value Description
1 Ding dong
2 Fur Elise
3 Westminster Chime
4 Dingdongdingdongdingdong
5 William Tell Overture
6 Classical
7 Weeooeeooeeooeeoo
8 Err-err-err-err-err
9 Beepbeepbeepbeep (Default)
10 beeeep-beeeep-beeeep

The manufacturer defined default value is 9 (Beepbeepbeepbeep (Default)).

This parameter has the configuration ID config_6_2 and is of type INTEGER.

Parameter 7: Toggle secondary chime

Toggles between primary and secondary chime for binary switch

The following option values may be configured -:

Value Description
1 Primary notification will play
2 Secondary notification will play

The manufacturer defined default value is 1 (Primary notification will play).

This parameter has the configuration ID config_7_2 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The DMS01 supports 3 association groups.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.

Association group 1 supports 5 nodes.

Group 2: Binary Switch Reports

Association group 2 supports 5 nodes.

Group 3: Notification Reports

Association group 3 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V6
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_INDICATOR_V1

Documentation Links