layout | title |
---|---|
documentation |
DTA19 - ZWave |
{% include base.html %}
This describes the Z-Wave device DTA19, manufactured by Domitech Products, LLC with the thing type UID of domitech_ze27_00_000
.
The device is in the category of Light Bulb, defining Devices that illuminate something, such as bulbs, etc..
The DTA19 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Domitech Smart LED Retrofit Kit ZE27EU is a member of the Z-Wave® family and communicate with other Z-Wave® certified devices in a control network. The Smart Bulb can be controlled by the Z-Wave remote controller or apps. Each Z-Wave device serves as a node to repeat the signal in the network, thus, extending the overall Z-Wave mesh wireless network range. Different types and brands of Z-Wave devices can be associated with domitech Smart Bulb in your system and they will work together to optimize and expand the coverage of your Z-Wave network. Once setup is completed, you can enjoy the convenience and leisure which Smart Bulb offers.
Step 1: Place the controller in inclusion mode.
Step 2: Turn on power to the socket after promoted by your network controller inclusion mode. The Smart Bulb will be included into your network within 30 seconds. The smart bulb will flash 2 times after Inclusion is successful. If the controller/gateway shows it failed, repeat the procedure.
Note: If Inclusion still fails after the 2nd attempt, you need to first RESET the Smart Bulb before repeating the above steps.
Before repeating the above steps, try moving the Smart Bulb to the bulb socket in the same room as your home gateway in case the preferred outlet is out of range initially. Repeat step 1-2 until the Smart Bulb is added to your network. Once the light bulb has been successfully added to your home network, you can move it to the preferred location in the home.
Manually Reset – Flick the wall switch “OFF-ON” cycle 4 times within 4 seconds (Turn OFF and turn ON will be counted as 1 “OFF-ON” cycle). The Smart Bulb will flash twice after Reset is successful. Use this procedure only in the event that the network primary controller is lost or otherwise inoperable.
By controller - The Smart Bulb can be excluded from your network by your controller/Gateway. Similar to the Inclusion process, turn off power to your light bulb and place your network controller into exclusion mode by following the controller manufacturer's instructions. Once prompted by your network controller, turn ON the light switch. The Smart Bulb will flash twice to confirm that it has successfully been excluded from your network. Please refer to your controller/gateway instructions manual for details.
Manually – The Smart Bulb can be excluded manually by flicking the wall switch ”OFF-ON” cycle 4 times within 4 seconds (Turn OFF and turn ON will be counted as 1 “OFF-ON” cycle). The bulb will flash twice after Reset is successful. Use this procedure only in the event that the network primary controller is lost or otherwise inoperable.
The following table summarises the channels available for the DTA19 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Dimmer | switch_dimmer | switch_dimmer | DimmableLight | Dimmer |
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer
channel is of type switch_dimmer
and supports the Dimmer
item and is in the DimmableLight
category.
The following table provides a summary of the 3 configuration parameters available in the DTA19. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Dim level when the bulb is turned on | Dim level when the bulb is turned on |
9 | Dimming / brightening step level | Controls the speed of dimming / brightening |
10 | Dimming / brightening step timing | Dimming / brightening step timing |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Dim level when the bulb is turned on You may select the dim level whenever the light is turned back on to be either full brightness (100% dim level) or be the same as the last dim setting when the light is on by flicking the wall switch. The following option values may be configured -:
Value | Description |
---|---|
0 | Full brightness |
1 | Last setting |
The manufacturer defined default value is 0
(Full brightness).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Controls the speed of dimming / brightening You may change the dimming step level when you adjust the brightness from your controller.
When the value is low, dimming / brightening is gradual. When the value is high, dimming / brightening is rapid. Values in the range 1 to 99 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_9_1
and is of type INTEGER
.
Dimming / brightening step timing This parameter controls the dimming speed. When the value is low, the step timing is quick. When the value is high, the step timing is slow. Values in the range 1 to 10 may be set.
The manufacturer defined default value is 3
.
This parameter has the configuration ID config_10_1
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The DTA19 supports 1 association group.
Association group 1 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.