layout | title |
---|---|
documentation |
MT02792 - ZWave |
{% include base.html %}
This describes the Z-Wave device MT02792, manufactured by Devolo with the thing type UID of devolo_mt2792_00_000
.
The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.
The MT02792 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
The devolo Home Control Smart Metering Plug is an intelligent wall socket that adds useful additional functions to all wall sockets present in the household. This enables connected devices to be switched on and off based on time control, either using rules configured in the Z-Wave-compatible control unit or using the corresponding app. In addition, the devolo Home Control Smart Metering Plug has an energy consumption measurement feature.
The Home Control Smart Metering Plug can be included using two different procedures:
Variant A: Auto Inclusion with the control unit
- In the Z-Wave-compatible control unit, start the procedure for adding a new device automatically.
- Plug the Home Control Smart Metering Plug into an available power socket. The Auto Inclusion is run. During the 2-minute timeout of the Auto Inclusion, Node Information Frames are sent within a few seconds. In the auto inclusion, it is not necessary to press the ON/OFF button.
Variant B: Manual Inclusion with the control unit If the time frame (2 minutes) of the Auto Inclusion procedure is exceeded, you can also include the Home Control Smart Metering Plug with the control unit manually.
- In the Z-Wave -compatible control unit, start the procedure for adding a new device (inclusion).
- Press the button of the connected Smart Metering Plug 3x within 1.2 seconds to start the inclusion process with the Z-Wave-compatible control unit.
- Put the Z-Wave controller in Exclusion mode.
- Press the ON/OFF button 3x within 1.2 seconds to put the device into Exclusion mode. (indicated by white LED: 0.5 sec. ON, 0.5 sec. OFF).
- Node ID is now removed. (After the removal, the device starts again with Auto Inclusion mode.) Reset: Press the ON/OFF button for at least 10 sec. to reset the device to the factory defaults. After the reboot, the device starts Auto Inclusion again.
The following table summarises the channels available for the MT02792 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Scene Number | scene_number | scene_number | Number | |
Electric meter (amps) | meter_current | meter_current | Energy | Number |
Electric meter (volts) | meter_voltage | meter_voltage | Energy | Number |
Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number |
Electric meter (power factor) | meter_powerfactor | meter_powerfactor | Energy | Number |
Electric meter (watts) | meter_watts | meter_watts | Energy | Number |
Electric meter (kVAh) | meter_kvah | meter_kvah | Energy | Number |
Electric meter (pulses) | meter_pulse | meter_pulse | Energy | Number |
Reset Meter | meter_reset | meter_reset | Energy | Switch |
Alarm | alarm_general | alarm_general | Alarm | Switch |
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Triggers when a scene button is pressed.
The scene_number
channel is of type scene_number
and supports the Number
item.
Indicates the instantaneous current consumption.
The meter_current
channel is of type meter_current
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous voltage.
The meter_voltage
channel is of type meter_voltage
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power factor.
The meter_powerfactor
channel is of type meter_powerfactor
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kVAh).
The meter_kvah
channel is of type meter_kvah
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the pulse count.
The meter_pulse
channel is of type meter_pulse
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Reset the meter.
The meter_reset
channel is of type meter_reset
and supports the Switch
item and is in the Energy
category.
Indicates if an alarm is triggered.
The alarm_general
channel is of type alarm_general
and supports the Switch
item and is in the Alarm
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
The following table provides a summary of the 9 configuration parameters available in the MT02792. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Watt counter reporting period | multiples of 5s |
2 | KWh counter reporting period | number of 10 minute intervals |
3 | Definition of warning of current load (A) | 1300*0.01A = 13A |
4 | load caution threshold | load caution threshold |
5 | Mode for restoring status | Restore switch state mode. |
6 | Switch OFF mode | Mode of switch off function. |
7 | LED display mode | Display device status |
8 | Auto off timer | Auto off timer. 0 will disable the auto off function. |
9 | Device from command status | RF off command mode |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
multiples of 5s Enable automatic interval in seconds reporting with an interval of 5s * the value. Set to 0 will disable the autoreporting function. The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
The manufacturer defined default value is 720
.
This parameter has the configuration ID config_1_2
and is of type INTEGER
.
number of 10 minute intervals Enable automatic interval in minutes reporting with an interval of 10min * the value. Set to 0 will disable the autoreporting function. The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
The manufacturer defined default value is 6
.
This parameter has the configuration ID config_2_2
and is of type INTEGER
.
1300*0.01A = 13A
Values in the range 10 to 1300 may be set.
The manufacturer defined default value is 1300
.
This parameter has the configuration ID config_3_2
and is of type INTEGER
.
load caution threshold Enable automatic warning when the accumulated kWh power consumption exceeds the setting value from 1KWh ~ 10000KWh.. Set to 0 will disable kWh load caution reporting. Values in the range 1 to 10000 may be set.
The manufacturer defined default value is 10000
.
This parameter has the configuration ID config_4_2
and is of type INTEGER
.
Restore switch state mode. Status of the plug if it is disconnected and reconnected from the mains power supply. The following option values may be configured -:
Value | Description |
---|---|
0 | Switch will remain Off. |
1 | resume previous state |
2 | Switch will turn On. |
The manufacturer defined default value is 1
(resume previous state).
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Mode of switch off function.
The following option values may be configured -:
Value | Description |
---|---|
0 | SWITCH OFF commands received are ignored. |
1 | SWITCH OFF commands received are honored. |
The manufacturer defined default value is 1
(SWITCH OFF commands received are honored.).
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
Display device status
The following option values may be configured -:
Value | Description |
---|---|
1 | The LED follows the state of the switch. |
2 | LED off with load ON |
3 | Flash mode |
The manufacturer defined default value is 1
(The LED follows the state of the switch.).
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
Auto off timer. 0 will disable the auto off function. If the Home Control Smart Metering Plug switches to ON, the auto-off timer starts counting down. After the timer is set to zero, the device shuts off automatically. If the auto-off timer function is set to 0, it is disabled.Default 0. The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_8_2
and is of type INTEGER
.
RF off command mode
The following option values may be configured -:
Value | Description |
---|---|
0 | When ALL OFF is received, MT2792 goes Off. |
1 | Ignore ALL OFF |
2 | If ALL OFF is received, turn ON if it is OFF |
3 | WhenALL OFF is received, the MT2792 goes On. |
The manufacturer defined default value is 0
(When ALL OFF is received, MT2792 goes Off.).
This parameter has the configuration ID config_9_1
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The MT02792 supports 1 association group.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. The device sends a notification report of the command class battery report, notification report, and local device reset notification, binary report.
Association group 1 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_SCENE_ACTIVATION_V1 | |
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1 | |
COMMAND_CLASS_METER_V3 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_PROTECTION_V2 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.