MT02647 Motion Sensor

This describes the Z-Wave device MT02647, manufactured by Devolo with the thing type UID of devolo_mt02647_00_000.

The device is in the category of Motion Detector, defining Motion sensors/detectors.

MT02647 product image

The MT02647 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

The MT02647 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.

Overview

Door/Window Contact and Motion Detector with temperature and illumination measurement.

Inclusion Information

  • Have Z-Wave Controller enter inclusion mode.
  • Press tamper key three times within 1.5 seconds to enter the inclusion mode.

Exclusion Information

  • Have Z-Wave Controller enter exclusion mode.
  • Pressing tamper key three times within 1.5 seconds to enter the exclusion mode.

RESET:

Notice: Use this procedure only in the event that the primary controller is lost or otherwise inoperable.

  • Pressing tamper key four times within 1.5 seconds and do not release the tamper key in the 4th pressed, and the LED will light ON.
  • After 3 seconds the LED will turn OFF, after that within 2 seconds, release the tamper key. If successful, the LED will light ON one second. Otherwise, the LED will flash once.
  • IDs are excluded and all settings will reset to factory default.

Wakeup Information

The MT02647 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.

The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.

  • After the device is added to the network, it will wake-up once per day in default. When it wakes up it will broadcast the “Wake Up Notification” message to the network, and wake-up 10 seconds for receiving the setting commands.
  • The wake-up interval minimum setting is 30 minutes, and maximum setting is 120 hours. And the interval step is 30 minutes.
  • If the user want to wake-up the device immediately, please remove the front cover, and press the tamper key once. The device will wake-up for 10 seconds.

General Usage Information

  • Parameter 7: Setting this Parameter to 20 is from user side wanted as this enables Binary Sensor to report OPEN / CLOSE status by changing Bit 4
  • The calculation from the recommended column is:  Bit7 to Bit0 = 000100100 Binary which is euqal to 20 decimal

Channels

The following table summarises the channels available for the MT02647 -:

Channel Name Channel ID Channel Type Category Item Type
Binary Sensor sensor_binary sensor_binary Switch
Sensor (luminance) sensor_luminance sensor_luminance Number
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number:Temperature
Alarm alarm_general alarm_general Alarm Switch
Battery Level battery-level system.battery_level Battery Number

Binary Sensor

Indicates if a sensor has triggered.

The sensor_binary channel is of type sensor_binary and supports the Switch item. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
ON Triggered
OFF Untriggered

Sensor (luminance)

Indicates the current light reading.

The sensor_luminance channel is of type sensor_luminance and supports the Number item. This is a read only channel so will only be updated following state changes from the device.

Sensor (temperature)

Indicates the current temperature.

The sensor_temperature channel is of type sensor_temperature and supports the Number:Temperature item and is in the Temperature category.

Alarm

Indicates if an alarm is triggered.

The alarm_general channel is of type alarm_general and supports the Switch item and is in the Alarm category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The system.battery-level channel is of type system.battery-level and supports the Number item and is in the Battery category. This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.

Device Configuration

The following table provides a summary of the 15 configuration parameters available in the MT02647. Detailed information on each parameter can be found in the sections below.

Param Name Description
2 Basic Set Level Setting the BASIC command value to turn on the light.
3 PIR Sensitivity Set the sensitivity for the PIR (Passive Infrared Sensor).
4 Light Threshold Set the illumination threshold to turn on the light.
5 Operation Mode Parameter to set the Operation Mode
6 Multi-Sensor Function Switch Parameter to set the sensor functions.
7 Customer Function Parameter to set the Customer Function.
8 PIR Re-Detect Interval Time Setting the re-detect time after motion detected
9 Turn Off Light Time Setting delay time to turn off the light when no motion
10 Auto Report Battery Time The interval time for auto reporting the battery level.
11 Auto Report Door/Window State Time Interval time for auto reporting the door/window state.
12 Auto Report Illumination Time The Interval time for auto reporting the illumination state.
13 Auto Report Temperature Time The interval time for auto reporting the temperature state.
20 Auto Report Tick Interval The interval time for each auto report tick.
21 Temperature Differential Report The temperature differential to report.
22 Illumination Differential Report The illumination differential to report.
Wakeup Interval Sets the interval at which the device will accept commands from the controller
Wakeup Node Sets the node ID of the device to receive the wakeup notifications
Lock Timeout Sets the time after which the door will auto lock

Parameter 2: Basic Set Level

Setting the BASIC command value to turn on the light.

  • 0: Turn off the light.
  • 1 - 100: For dimmers 1 to 100 means the light level.
  • 255: Turns on the light. (Default)  The following option values may be configured -:
Value Description
0 Off
255 On

The manufacturer defined default value is 255 (On).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: PIR Sensitivity

Set the sensitivity for the PIR (Passive Infrared Sensor).

  • 0 = Disable the PIR motion detection.
  • 1 - 99 = 1 means the lowest sensitivity, 99 means the highest sensitivity The following option values may be configured -:
Value Description
0 Disable

The manufacturer defined default value is 70.

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Light Threshold

Set the illumination threshold to turn on the light. When the event triggered and the environment illumination lower then the threshold, the device will turn on the light.

0 means turn off illumination detected function. And never turn on the light.

1 means darkest.99 means brightest.

100 means turn off illumination detected function. And always turn on the light. The following option values may be configured -:

Value Description
0 Disable

The manufacturer defined default value is 100.

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Operation Mode

Parameter to set the Operation Mode Parameter to set the Operation Mode. 

Bit 0: Reserved. 

Bit 1: 1 means enable test mode; 0 means normal mode.

Notice: Ignored if DIP Switch is not set to Customer Mode. 

Bit 2: Disable the door/window function. Values in the range 0 to 127 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 6: Multi-Sensor Function Switch

Parameter to set the sensor functions. Parameter to set the sensor functions.  

Bit 0: Disable magnetic integrate illumination to turn on the lighting nodes in the association group 2. 1: Disable, 0: Enable 

Bit 1: Disable PIR integrate Illumination to turn on the light Values in the range 0 to 127 may be set.

The manufacturer defined default value is 4.

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Parameter 7: Customer Function

Parameter to set the Customer Function. Parameter 7 Customer Function:

<td>
  Default
</td>

<td>
  Recommended
</td>
<td>
  unused
</td>

<td>
   
</td>
<td>
  unused
</td>

<td>
   
</td>
<td>
  unused
</td>

<td>
   
</td>
<td>
  Disable send out BASIC OFF after door closed. (1:Disable, 0:Enable)
</td>

<td>
</td>
<td>
  Notification Type, 0: Using Notification Report. 1: Using Sensor Binary Report
</td>

<td>
  1
</td>
<td>
  Disable Multi CC in auto report. (1:Disable, 0:Enable)
</td>

<td>
</td>
<td>
  Disable to report battery state when the device triggered. (1:Disable, 10 0:Enable)
</td>

<td>
</td>
<td>
  unused
</td>

<td>
   
</td>
Bits
1
2
3
4
5
6
7

Comments / Tips for this device from the community:

  • Setting this Parameter to 20 is from user side wanted as this enables Binary Sensor to report OPEN / CLOSE status by changing Bit 4
  • The calculation from the recommended column is:  Bit7 to Bit0 = 000100100 Binary which is euqal to 20 decimal Values in the range 0 to 127 may be set.

The manufacturer defined default value is 4.

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 8: PIR Re-Detect Interval Time

Setting the re-detect time after motion detected In the normal mode, after the PIR motion detected, setting the re-detect time. 8 seconds per tick, default is 3 (24 seconds). 

1 - 127 = Number of ticks. 8 seconds per tick, default value is 3 (24 seconds) Values in the range 1 to 127 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_8_1 and is of type INTEGER.

Parameter 9: Turn Off Light Time

Setting delay time to turn off the light when no motion After turn on the light, setting the delay time to turn off the light when the PIR motion is not detected. 

0 = Never send turn off light command.   

1 - 127 = Number of ticks. 8 seconds per tick, default value is 4 (32 seconds Values in the range 0 to 127 may be set.

The manufacturer defined default value is 4.

This parameter has the configuration ID config_9_1 and is of type INTEGER.

Parameter 10: Auto Report Battery Time

The interval time for auto reporting the battery level. The interval time for auto reporting the battery level.  

0 = Turn off auto report battery.  

1-127 = Number of ticks. The default value is 12. The tick time can be set by configuration No. 20 Values in the range 0 to 127 may be set.

The manufacturer defined default value is 12.

This parameter has the configuration ID config_10_1 and is of type INTEGER.

Parameter 11: Auto Report Door/Window State Time

Interval time for auto reporting the door/window state. The interval time for auto reporting the door/window state.   

0 = Turn off auto report door/window state. 

1-127 = Number of ticks. The default value is 12. The tick time can be set by configuration No. 20. Values in the range 0 to 127 may be set.

The manufacturer defined default value is 12.

This parameter has the configuration ID config_11_1 and is of type INTEGER.

Parameter 12: Auto Report Illumination Time

The Interval time for auto reporting the illumination state.

Values in the range 1 to 127 may be set.

The manufacturer defined default value is 12.

This parameter has the configuration ID config_12_1 and is of type INTEGER.

Parameter 13: Auto Report Temperature Time

The interval time for auto reporting the temperature state. The interval time for auto reporting the temperature state.       

0 = Turn off auto report temperature.       

1-127 = Number of ticks. The default value is 12. The tick time can be set by configuration No. 20. Values in the range 1 to 127 may be set.

The manufacturer defined default value is 12.

This parameter has the configuration ID config_13_1 and is of type INTEGER.

Parameter 20: Auto Report Tick Interval

The interval time for each auto report tick. The interval time for each auto report tick. Setting this configuration will effect configuration No.10, No.11, No.12 and No.13. 

0 = Turn off all auto report functions. 

1-255 = Interval time for each tick. Default is 30. Unit is in minutes Values in the range 0 to 255 may be set.

The manufacturer defined default value is 30.

This parameter has the configuration ID config_20_1 and is of type INTEGER.

Parameter 21: Temperature Differential Report

The temperature differential to report. The temperature differential to report. The unit is Fahrenheit. When enabled, the device will measure the temperature every minute and when the temperature is over 140 degree Fahrenheit, it will continuesly report. Values in the range 0 to 127 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_21_1 and is of type INTEGER.

Parameter 22: Illumination Differential Report

The illumination differential to report. The illumination differential to report. The unit is percentage. When enabled, the device will measure every minute. Enabling this functionality will cause some issue. Please check the “Illumination Report” section of the Multisensor manual. Values in the range 0 to 99 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_22_1 and is of type INTEGER.

Wakeup Interval

The wakeup interval sets the period at which the device will listen for messages from the controller. This is required for battery devices that sleep most of the time in order to conserve battery life. The device will wake up at this interval and send a message to the controller to tell it that it can accept messages - after a few seconds, it will go back to sleep if there is no further communications.

This setting is defined in seconds. It is advisable not to set this interval too short or it could impact battery life. A period of 1 hour (3600 seconds) is suitable in most instances.

Note that this setting does not affect the devices ability to send sensor data, or notification events.

This parameter has the configuration ID wakeup_interval and is of type INTEGER.

Wakeup Node

When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address. In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.

This parameter has the configuration ID wakeup_node and is of type INTEGER.

Lock Timeout

Sets the time after which the door will auto lock.

This parameter has the configuration ID doorlock_timeout and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The MT02647 supports 2 association groups.

Group 1: Reports

Association group 1 supports 8 nodes.

Group 2: Light Control

Association group 2 supports 8 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SENSOR_BINARY_V2
COMMAND_CLASS_SENSOR_MULTILEVEL_V5
COMMAND_CLASS_DOOR_LOCK_V1
COMMAND_CLASS_USER_CODE_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V1 Linked to BASIC
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_PROTECTION_V1
COMMAND_CLASS_LOCK_V1
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1
COMMAND_CLASS_MULTI_CMD_V1
COMMAND_CLASS_SECURITY_V1

Documentation Links