DAD-101 - ZWave

{% include base.html %}

DAD-101 Dimmer with sensors support

This describes the Z-Wave device DAD-101, manufactured by Defaro with the thing type UID of defaro_dad101_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

DAD-101 product image

The DAD-101 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

One channel dimmer with ability to add different sensors to it.

Inclusion Information

  1. Put controller in inclusion mode.
  2. Power on device. It should be added automatically (using NWI).
  3. If not fast press add/remove button three times.

Exclusion Information

  1. Put controller in exclusion mode.
  2. Fast press add/remove button three times.

Channels

The following table summarises the channels available for the DAD-101 -:

Channel Name Channel ID Channel Type Category Item Type
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer
Sensor (power) sensor_power sensor_power Energy Number
Dimmer switch_dimmer1 switch_dimmer DimmableLight Dimmer

Dimmer

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel is of type switch_dimmer and supports the Dimmer item and is in the DimmableLight category.

Sensor (power)

Indicates the energy consumption (kWh).

The sensor_power channel is of type sensor_power and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Dimmer

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer1 channel is of type switch_dimmer and supports the Dimmer item and is in the DimmableLight category.

Device Configuration

The following table provides a summary of the 21 configuration parameters available in the DAD-101. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Load type Dimmer load type
2 Min dimming level
3 Max dimming level
4 Dimming speed Dimming speed
5 Auto Off delay Delay to turn device OFF after ON command received
6 All ON/OFF behaviour All ON/OFF behaviour
7 Powerfail recovery Powerfail recovery mode
8 Lighting autolevel Autolevel behavior
9 Light level Light level to maintain
10 Lighting change trigger threshold Lighting change trigger threshold
12 Turn on delay Sets turn on delay
13 Smart delay for dimmer Smart delay for dimmer
14 Smart delay mode Smart delay mode
15 Load in Watts Lamps load in Watts
16 S1 button mode S1 button operation mode
17 S2 button mode S2 button operation mode
18 Double click to max Level up to max on double click
21 Sensor driven dimmer Sets sensor for dimmer control
22 Sensor 1 ON command value Sensor 1 ON command value
23 Sensor 1 command OFF value Value to activate OFF command for Sensor 1
24 Sensor 1 ON/OFF command behavior Behavior for ON/OFF command
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: Load type

Dimmer load type

The following option values may be configured -:

Value Description
0 Normal lamps
1 Induction low volt halogen lamps
2 Electronic low volt halogen lamps
3 LED 220V lamps
4 Non-dimmable lamps

The manufacturer defined default value is 3 (LED 220V lamps).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Min dimming level

Values in the range 1 to 94 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Max dimming level

Values in the range 6 to 99 may be set.

The manufacturer defined default value is 99.

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Dimming speed

Dimming speed Dimming speed in seconds (0 - instantly) WARNING - 0 does not work correctly, it leaves 11-15V AC on the terminals. Use 1 instead! The following option values may be configured, in addition to values in the range 0 to 120 -:

Value Description
0 Disable
1 Fastest

The manufacturer defined default value is 5.

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Auto Off delay

Delay to turn device OFF after ON command received Sets time after which dimmer will turn off after receiving ON command in 1 sec. (0 - disable feature) The following option values may be configured, in addition to values in the range 0 to 650 -:

Value Description
0 Disable

The manufacturer defined default value is 0 (Disable).

This parameter has the configuration ID config_5_2 and is of type INTEGER.

Parameter 6: All ON/OFF behaviour

All ON/OFF behaviour 0 - React on All ON/All OFF

1 - Ignore All ON/All OFF

2 - Ignore All ON/React on All OFF

3 - React on All ON/Ignore All OFF Values in the range 0 to 3 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Parameter 7: Powerfail recovery

Powerfail recovery mode

The following option values may be configured -:

Value Description
0 Restore previous state
1 Always set to OFF state

The manufacturer defined default value is 0 (Restore previous state).

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 8: Lighting autolevel

Autolevel behavior This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -:

Value Description
0 Off
1 On
2 Use with motion sensor

The manufacturer defined default value is 0 (OFF).

This parameter has the configuration ID config_8_1 and is of type INTEGER.

Parameter 9: Light level

Light level to maintain In lumensThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured, in addition to values in the range 0 to 4000 -:

Value Description
150 Default

The manufacturer defined default value is 150 (Default).

This parameter has the configuration ID config_9_2 and is of type INTEGER.

Parameter 10: Lighting change trigger threshold

Lighting change trigger threshold In lumensThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured, in addition to values in the range 1 to 300 -:

Value Description
1 Min
10 Default
300 Max

The manufacturer defined default value is 10 (Default).

This parameter has the configuration ID config_10_2 and is of type INTEGER.

Parameter 12: Turn on delay

Sets turn on delay In seconds The following option values may be configured, in addition to values in the range 0 to 1800 -:

Value Description
0 Disable

The manufacturer defined default value is 0 (Disable).

This parameter has the configuration ID config_12_2 and is of type INTEGER.

Parameter 13: Smart delay for dimmer

Smart delay for dimmer In seconds (see Parameter 14)This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured, in addition to values in the range 0 to 1800 -:

Value Description
0 Disable

The manufacturer defined default value is 0 (Disable).

This parameter has the configuration ID config_13_2 and is of type INTEGER.

Parameter 14: Smart delay mode

Smart delay mode DAD-101

0 - implicit smart delay

1 - use smart delay for all devices NOT in Group 1. Also smart delay ignored for controller and button issued commands

2 - use smart delay for all devices IN Group 1. Also smart delay will be used for controller and button issued commandsThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 2 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_14_1 and is of type INTEGER.

Parameter 15: Load in Watts

Lamps load in Watts

The following option values may be configured, in addition to values in the range 0 to 5000 -:

Value Description
0 Disable

The manufacturer defined default value is 0 (Disable).

This parameter has the configuration ID config_15_2 and is of type INTEGER.

Parameter 16: S1 button mode

S1 button operation mode Type of button connected to switch The following option values may be configured -:

Value Description
0 Monostable (push button)
1 Bistable (switch)
2 Bistable (fixed switch)
3 Bistable (reversed fixed switch)
4 Two monostable switches

The manufacturer defined default value is 0 (Monostable (push button)).

This parameter has the configuration ID config_16_1 and is of type INTEGER.

Parameter 17: S2 button mode

S2 button operation mode Type of button connected to S2 switch The following option values may be configured -:

Value Description
0 Monostable (push button)
1 Bistable (switch button)
2 Bistable (fixed switch button)
3 Bistable (reversed fixed switch)

The manufacturer defined default value is 0 (Monostable (push button)).

This parameter has the configuration ID config_17_1 and is of type INTEGER.

Parameter 18: Double click to max

Level up to max on double click

The following option values may be configured -:

Value Description
0 Ignore double click
1 Double click sets 100%

The manufacturer defined default value is 1 (Double click sets 100%).

This parameter has the configuration ID config_18_1 and is of type INTEGER.

Parameter 21: Sensor driven dimmer

Sets sensor for dimmer control 0 - off

1 - sensor 1

2 - sensor 2This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -:

Value Description
0 Off
1 Sensor 1
2 Sensor 2

The manufacturer defined default value is 0 (OFF).

This parameter has the configuration ID config_21_1 and is of type INTEGER.

Parameter 22: Sensor 1 ON command value

Sensor 1 ON command value Commands send to AG 6 The following option values may be configured, in addition to values in the range -60 to 1000 -:

Value Description
0 Disabled
1000 Max

The manufacturer defined default value is 0 (Disabled).

This parameter has the configuration ID config_22_2 and is of type INTEGER.

Parameter 23: Sensor 1 command OFF value

Value to activate OFF command for Sensor 1 For AG 6 Values in the range -60 to 1000 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_23_2 and is of type INTEGER.

Parameter 24: Sensor 1 ON/OFF command behavior

Behavior for ON/OFF command Please see docs Values in the range 0 to 6 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_24_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The DAD-101 supports 7 association groups.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. State changes

Association group 1 supports 1 node.

Group 2: Switch 1

Switch 1 ON/OFF associations

Association group 2 supports 10 nodes.

Group 3: Switch1 dimmer

Dimmer status group for S1

Association group 3 supports 10 nodes.

Group 4: Switch 2

Switch 2 ON/OFF associations

Association group 4 supports 10 nodes.

Group 5: Switch 2 dimmer

Dimmer status group for S2

Association group 5 supports 10 nodes.

Group 6: Sensor 1

Group for Sensor 1 states

Association group 6 supports 10 nodes.

Group 7: Sensor 2

Group for Sensor 2 states

Association group 7 supports 10 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2

Endpoint 1

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V1 Linked to BASIC

Documentation Links