DAD-101 - ZWave |
{% include base.html %}
This describes the Z-Wave device DAD-101, manufactured by Defaro with the thing type UID of defaro_dad101_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The DAD-101 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
One channel dimmer with ability to add different sensors to it.
- Put controller in inclusion mode.
- Power on device. It should be added automatically (using NWI).
- If not fast press add/remove button three times.
- Put controller in exclusion mode.
- Fast press add/remove button three times.
The following table summarises the channels available for the DAD-101 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Dimmer | switch_dimmer | switch_dimmer | DimmableLight | Dimmer |
Sensor (power) | sensor_power | sensor_power | Energy | Number |
Dimmer | switch_dimmer1 | switch_dimmer | DimmableLight | Dimmer |
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer
channel is of type switch_dimmer
and supports the Dimmer
item and is in the DimmableLight
category.
Indicates the energy consumption (kWh).
The sensor_power
channel is of type sensor_power
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer1
channel is of type switch_dimmer
and supports the Dimmer
item and is in the DimmableLight
category.
The following table provides a summary of the 21 configuration parameters available in the DAD-101. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Load type | Dimmer load type |
2 | Min dimming level | |
3 | Max dimming level | |
4 | Dimming speed | Dimming speed |
5 | Auto Off delay | Delay to turn device OFF after ON command received |
6 | All ON/OFF behaviour | All ON/OFF behaviour |
7 | Powerfail recovery | Powerfail recovery mode |
8 | Lighting autolevel | Autolevel behavior |
9 | Light level | Light level to maintain |
10 | Lighting change trigger threshold | Lighting change trigger threshold |
12 | Turn on delay | Sets turn on delay |
13 | Smart delay for dimmer | Smart delay for dimmer |
14 | Smart delay mode | Smart delay mode |
15 | Load in Watts | Lamps load in Watts |
16 | S1 button mode | S1 button operation mode |
17 | S2 button mode | S2 button operation mode |
18 | Double click to max | Level up to max on double click |
21 | Sensor driven dimmer | Sets sensor for dimmer control |
22 | Sensor 1 ON command value | Sensor 1 ON command value |
23 | Sensor 1 command OFF value | Value to activate OFF command for Sensor 1 |
24 | Sensor 1 ON/OFF command behavior | Behavior for ON/OFF command |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Dimmer load type
The following option values may be configured -:
Value | Description |
---|---|
0 | Normal lamps |
1 | Induction low volt halogen lamps |
2 | Electronic low volt halogen lamps |
3 | LED 220V lamps |
4 | Non-dimmable lamps |
The manufacturer defined default value is 3
(LED 220V lamps).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Values in the range 1 to 94 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Values in the range 6 to 99 may be set.
The manufacturer defined default value is 99
.
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Dimming speed Dimming speed in seconds (0 - instantly) WARNING - 0 does not work correctly, it leaves 11-15V AC on the terminals. Use 1 instead! The following option values may be configured, in addition to values in the range 0 to 120 -:
Value | Description |
---|---|
0 | Disable |
1 | Fastest |
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Delay to turn device OFF after ON command received Sets time after which dimmer will turn off after receiving ON command in 1 sec. (0 - disable feature) The following option values may be configured, in addition to values in the range 0 to 650 -:
Value | Description |
---|---|
0 | Disable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_5_2
and is of type INTEGER
.
All ON/OFF behaviour 0 - React on All ON/All OFF
1 - Ignore All ON/All OFF
2 - Ignore All ON/React on All OFF
3 - React on All ON/Ignore All OFF Values in the range 0 to 3 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
Powerfail recovery mode
The following option values may be configured -:
Value | Description |
---|---|
0 | Restore previous state |
1 | Always set to OFF state |
The manufacturer defined default value is 0
(Restore previous state).
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
Autolevel behavior This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -:
Value | Description |
---|---|
0 | Off |
1 | On |
2 | Use with motion sensor |
The manufacturer defined default value is 0
(OFF).
This parameter has the configuration ID config_8_1
and is of type INTEGER
.
Light level to maintain In lumensThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured, in addition to values in the range 0 to 4000 -:
Value | Description |
---|---|
150 | Default |
The manufacturer defined default value is 150
(Default).
This parameter has the configuration ID config_9_2
and is of type INTEGER
.
Lighting change trigger threshold In lumensThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured, in addition to values in the range 1 to 300 -:
Value | Description |
---|---|
1 | Min |
10 | Default |
300 | Max |
The manufacturer defined default value is 10
(Default).
This parameter has the configuration ID config_10_2
and is of type INTEGER
.
Sets turn on delay In seconds The following option values may be configured, in addition to values in the range 0 to 1800 -:
Value | Description |
---|---|
0 | Disable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_12_2
and is of type INTEGER
.
Smart delay for dimmer In seconds (see Parameter 14)This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured, in addition to values in the range 0 to 1800 -:
Value | Description |
---|---|
0 | Disable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_13_2
and is of type INTEGER
.
Smart delay mode DAD-101
0 - implicit smart delay
1 - use smart delay for all devices NOT in Group 1. Also smart delay ignored for controller and button issued commands
2 - use smart delay for all devices IN Group 1. Also smart delay will be used for controller and button issued commandsThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 2 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_14_1
and is of type INTEGER
.
Lamps load in Watts
The following option values may be configured, in addition to values in the range 0 to 5000 -:
Value | Description |
---|---|
0 | Disable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_15_2
and is of type INTEGER
.
S1 button operation mode Type of button connected to switch The following option values may be configured -:
Value | Description |
---|---|
0 | Monostable (push button) |
1 | Bistable (switch) |
2 | Bistable (fixed switch) |
3 | Bistable (reversed fixed switch) |
4 | Two monostable switches |
The manufacturer defined default value is 0
(Monostable (push button)).
This parameter has the configuration ID config_16_1
and is of type INTEGER
.
S2 button operation mode Type of button connected to S2 switch The following option values may be configured -:
Value | Description |
---|---|
0 | Monostable (push button) |
1 | Bistable (switch button) |
2 | Bistable (fixed switch button) |
3 | Bistable (reversed fixed switch) |
The manufacturer defined default value is 0
(Monostable (push button)).
This parameter has the configuration ID config_17_1
and is of type INTEGER
.
Level up to max on double click
The following option values may be configured -:
Value | Description |
---|---|
0 | Ignore double click |
1 | Double click sets 100% |
The manufacturer defined default value is 1
(Double click sets 100%).
This parameter has the configuration ID config_18_1
and is of type INTEGER
.
Sets sensor for dimmer control 0 - off
1 - sensor 1
2 - sensor 2This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -:
Value | Description |
---|---|
0 | Off |
1 | Sensor 1 |
2 | Sensor 2 |
The manufacturer defined default value is 0
(OFF).
This parameter has the configuration ID config_21_1
and is of type INTEGER
.
Sensor 1 ON command value Commands send to AG 6 The following option values may be configured, in addition to values in the range -60 to 1000 -:
Value | Description |
---|---|
0 | Disabled |
1000 | Max |
The manufacturer defined default value is 0
(Disabled).
This parameter has the configuration ID config_22_2
and is of type INTEGER
.
Value to activate OFF command for Sensor 1 For AG 6 Values in the range -60 to 1000 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_23_2
and is of type INTEGER
.
Behavior for ON/OFF command Please see docs Values in the range 0 to 6 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_24_1
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The DAD-101 supports 7 association groups.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. State changes
Association group 1 supports 1 node.
Switch 1 ON/OFF associations
Association group 2 supports 10 nodes.
Dimmer status group for S1
Association group 3 supports 10 nodes.
Switch 2 ON/OFF associations
Association group 4 supports 10 nodes.
Dimmer status group for S2
Association group 5 supports 10 nodes.
Group for Sensor 1 states
Association group 6 supports 10 nodes.
Group for Sensor 2 states
Association group 7 supports 10 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2 |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V1 | Linked to BASIC |