Skip to content

Latest commit

 

History

History
executable file
·
118 lines (72 loc) · 5.02 KB

dthermz6_0_0.md

File metadata and controls

executable file
·
118 lines (72 loc) · 5.02 KB
layout title
documentation
DTHERMZ6 - ZWave

{% include base.html %}

DTHERMZ6 Living Connect Z Thermostat

This describes the Z-Wave device DTHERMZ6, manufactured by Danfoss with the thing type UID of danfoss_dthermz6_00_000.

The device is in the category of HVAC, defining Air condition devices, Fans.

DTHERMZ6 product image

The DTHERMZ6 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

The DTHERMZ6 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.

Overview

DTHERMZ6 is an electronic radiator thermostat, intended for using with water based room radiators

Inclusion Information

Quickly press ans release the "Down" button on DTHERMZ26

Exclusion Information

Quickly press ans release the "Down" button on DTHERMZ26

Wakeup Information

The DTHERMZ6 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.

The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.

Not Provided

Channels

The following table summarises the channels available for the DTHERMZ6 -:

Channel Name Channel ID Channel Type Category Item Type
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number:Temperature
Setpoint (heating) thermostat_setpoint thermostat_setpoint Heating Number:Temperature
Battery Level battery-level system.battery_level Battery Number
Clock Time Offset time_offset time_offset Time Number

Sensor (temperature)

Indicates the current temperature.

The sensor_temperature channel is of type sensor_temperature and supports the Number:Temperature item and is in the Temperature category.

Setpoint (heating)

Sets the thermostat setpoint.

The thermostat_setpoint channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The system.battery-level channel is of type system.battery-level and supports the Number item and is in the Battery category. This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.

Clock Time Offset

Provides the current time difference for the devices time.

The time_offset channel is of type time_offset and supports the Number item and is in the Time category.

Device Configuration

The device has no configuration parameters defined.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The DTHERMZ6 supports 1 association group.

Group 1: Target for Wakeup and Override Notifications

Association group 1 supports 1 node.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V6
COMMAND_CLASS_THERMOSTAT_SETPOINT_V1
COMMAND_CLASS_CLIMATE_CONTROL_SCHEDULE_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_PROTECTION_V2
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_CLOCK_V1
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1
COMMAND_CLASS_MULTI_CMD_V1

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.