layout | title |
---|---|
documentation |
DTHERMZ6 - ZWave |
{% include base.html %}
This describes the Z-Wave device DTHERMZ6, manufactured by Danfoss with the thing type UID of danfoss_dthermz6_00_000
.
The device is in the category of HVAC, defining Air condition devices, Fans.
The DTHERMZ6 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The DTHERMZ6 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.
DTHERMZ6 is an electronic radiator thermostat, intended for using with water based room radiators
Quickly press ans release the "Down" button on DTHERMZ26
Quickly press ans release the "Down" button on DTHERMZ26
The DTHERMZ6 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.
The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
Not Provided
The following table summarises the channels available for the DTHERMZ6 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Sensor (temperature) | sensor_temperature | sensor_temperature | Temperature | Number:Temperature |
Setpoint (heating) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature |
Battery Level | battery-level | system.battery_level | Battery | Number |
Clock Time Offset | time_offset | time_offset | Time | Number |
Indicates the current temperature.
The sensor_temperature
channel is of type sensor_temperature
and supports the Number:Temperature
item and is in the Temperature
category.
Sets the thermostat setpoint.
The thermostat_setpoint
channel is of type thermostat_setpoint
and supports the Number:Temperature
item and is in the Heating
category.
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The system.battery-level
channel is of type system.battery-level
and supports the Number
item and is in the Battery
category.
This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.
Provides the current time difference for the devices time.
The time_offset
channel is of type time_offset
and supports the Number
item and is in the Time
category.
The device has no configuration parameters defined.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The DTHERMZ6 supports 1 association group.
Association group 1 supports 1 node.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V6 | |
COMMAND_CLASS_THERMOSTAT_SETPOINT_V1 | |
COMMAND_CLASS_CLIMATE_CONTROL_SCHEDULE_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_PROTECTION_V2 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_CLOCK_V1 | |
COMMAND_CLASS_WAKE_UP_V2 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 | |
COMMAND_CLASS_MULTI_CMD_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.