{% include base.html %}

014G0210 HC-Z Hydronic Floor Heating Controller

This describes the Z-Wave device 014G0210, manufactured by Danfoss with the thing type UID of danfoss_014g0210_00_000.

The device is in the category of Radiator Control, defining Controls on radiators used to heat up rooms.

014G0210 product image

The 014G0210 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

Product information "Danfoss HC10 (Hydronic contoller for 10 outputs)"

The Danfoss HC (Hydronic Controller) is part of the wireless Z-wave controlsystems for heating systems in residential homes.

The Danfoss HC allows the control of warmwater floor heating systems. The system offers a big bandwidth of advanced functions for optimal comfort and energy savings and allows a single room temperature control.

The Danfoss HC includes among other things: 10 short circiut safe outputs for 24V actuator drives NC or NO, Relays for pump and boilercontrol, self-testing program, regulation by ON/OFF- or PWM-principle (pulse width modulation) etc.

The system can exist of multiple Danfoss HC for bigger systems with more than 10 actuators drives. The Danfoss HC has a direct connector to a power supply of 230V. Because of that you do not need an additional transformer but all actuator drives will be supplied with 24V power.

 Features:

  • Controlling of warmwater floor heating systems
  • 10 short circuit protected outputs with LED notice
  • Output for 24V actuator drive NC or NO
  • Guarantee of valve function at alle outputs even when there is temperatur control, every 14 day valve movement for ca. 12 minutes
  • Regulation by PWM-principle (pulse width modulation)
  • Relays for pump regulation with automatic 1 minute pump start-up on every third day, to avoid damages during the Standby time periods
  • Relays for boiler regulation, only active during warming needs
  • Automatic self diagnostics to show lost connection to the device
  • Wireless technologie: Z-Wave

Inclusion Information

To include the Hydronic Controller in Z-Wave follow the procedure:

  • Verify Hydronic Controller indicates "not included" on the MMI.
  • Activate "Inclusion" on the Z-Wave Controller
  • Press the button on the Hydronic Controller
  • Observe Hydronic Controller indicate included on the MMI

Exclusion Information

Exclusion can be done in two ways:

1. Initiated from the Controller

  • Verify Hydronic Controller indicate "Included" on the MMI. "Fault" indication also covers "Included".
  • Activate "Exclusion" on the controller
  • Press the button on the Hydronic Controller
  • Observe Hydronic Controller indicate not included in a network on the MMI.

2. Initiated from the Hydronic Controller by a factory reset to default

  • Verify the Hydronic Controller indicate "Included" or "Fault" on the MMI
  • Remove the mains power from the Hydronic Controller
  • Wait for 15 seconds
  • Press and hold the button while applying mains power. LED will light RED while leaving network.
  • Observe the Hydronic Controller indicate not included in a network on the MMI

Channels

The following table summarises the channels available for the 014G0210 -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch
Thermostat mode thermostat_mode thermostat_mode Temperature Number
Setpoint (heating) thermostat_setpoint thermostat_setpoint Heating Number:Temperature
Alarm alarm_general alarm_general Alarm Switch
Thermostat mode 1 thermostat_mode1 thermostat_mode Temperature Number
Setpoint (heating) 1 thermostat_setpoint1 thermostat_setpoint Heating Number:Temperature
Alarm 1 alarm_general1 alarm_general Alarm Switch
Indicator 1 indicator_flash1 indicator_flash Number
Thermostat mode 2 thermostat_mode2 thermostat_mode Temperature Number
Setpoint (heating) 2 thermostat_setpoint2 thermostat_setpoint Heating Number:Temperature
Alarm 2 alarm_general2 alarm_general Alarm Switch
Thermostat mode 3 thermostat_mode3 thermostat_mode Temperature Number
Setpoint (heating) 3 thermostat_setpoint3 thermostat_setpoint Heating Number:Temperature
Alarm 3 alarm_general3 alarm_general Alarm Switch
Thermostat mode 4 thermostat_mode4 thermostat_mode Temperature Number
Setpoint (heating) 4 thermostat_setpoint4 thermostat_setpoint Heating Number:Temperature
Alarm 4 alarm_general4 alarm_general Alarm Switch
Thermostat mode 5 thermostat_mode5 thermostat_mode Temperature Number
Setpoint (heating) 5 thermostat_setpoint5 thermostat_setpoint Heating Number:Temperature
Alarm 5 alarm_general5 alarm_general Alarm Switch
Thermostat mode 6 thermostat_mode6 thermostat_mode Temperature Number
Setpoint (heating) 6 thermostat_setpoint6 thermostat_setpoint Heating Number:Temperature
Alarm 6 alarm_general6 alarm_general Alarm Switch
Thermostat mode 7 thermostat_mode7 thermostat_mode Temperature Number
Setpoint (heating) 7 thermostat_setpoint7 thermostat_setpoint Heating Number:Temperature
Alarm 7 alarm_general7 alarm_general Alarm Switch
Thermostat mode 8 thermostat_mode8 thermostat_mode Temperature Number
Setpoint (heating) 8 thermostat_setpoint8 thermostat_setpoint Heating Number:Temperature
Alarm 8 alarm_general8 alarm_general Alarm Switch
Thermostat mode 9 thermostat_mode9 thermostat_mode Temperature Number
Setpoint (heating) 9 thermostat_setpoint9 thermostat_setpoint Heating Number:Temperature
Alarm 9 alarm_general9 alarm_general Alarm Switch
Thermostat mode 10 thermostat_mode10 thermostat_mode Temperature Number
Setpoint (heating) 10 thermostat_setpoint10 thermostat_setpoint Heating Number:Temperature
Alarm 10 alarm_general10 alarm_general Alarm Switch
Switch 11 switch_binary11 switch_binary Switch Switch
Switch 12 switch_binary12 switch_binary Switch Switch

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Thermostat mode

Sets the thermostat.

The thermostat_mode channel is of type thermostat_mode and supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Off
1 Heat
2 Cool
3 Auto
4 Aux Heat
5 Resume
6 Fan Only
7 Furnace
8 Dry Air
9 Moist Air
10 Auto Changeover
11 Heat Economy
12 Cool Economy
13 Away

Setpoint (heating)

Sets the thermostat setpoint.

The thermostat_setpoint channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Alarm

Indicates if an alarm is triggered.

The alarm_general channel is of type alarm_general and supports the Switch item and is in the Alarm category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Thermostat mode 1

Sets the thermostat.

The thermostat_mode1 channel is of type thermostat_mode and supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Off
1 Heat
2 Cool
3 Auto
4 Aux Heat
5 Resume
6 Fan Only
7 Furnace
8 Dry Air
9 Moist Air
10 Auto Changeover
11 Heat Economy
12 Cool Economy
13 Away

Setpoint (heating) 1

Sets the thermostat setpoint.

The thermostat_setpoint1 channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Alarm 1

Indicates if an alarm is triggered.

The alarm_general1 channel is of type alarm_general and supports the Switch item and is in the Alarm category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Indicator 1

Sets the number of indicator flash cycles.

The indicator_flash1 channel is of type indicator_flash and supports the Number item.

Thermostat mode 2

Sets the thermostat.

The thermostat_mode2 channel is of type thermostat_mode and supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Off
1 Heat
2 Cool
3 Auto
4 Aux Heat
5 Resume
6 Fan Only
7 Furnace
8 Dry Air
9 Moist Air
10 Auto Changeover
11 Heat Economy
12 Cool Economy
13 Away

Setpoint (heating) 2

Sets the thermostat setpoint.

The thermostat_setpoint2 channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Alarm 2

Indicates if an alarm is triggered.

The alarm_general2 channel is of type alarm_general and supports the Switch item and is in the Alarm category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Thermostat mode 3

Sets the thermostat.

The thermostat_mode3 channel is of type thermostat_mode and supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Off
1 Heat
2 Cool
3 Auto
4 Aux Heat
5 Resume
6 Fan Only
7 Furnace
8 Dry Air
9 Moist Air
10 Auto Changeover
11 Heat Economy
12 Cool Economy
13 Away

Setpoint (heating) 3

Sets the thermostat setpoint.

The thermostat_setpoint3 channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Alarm 3

Indicates if an alarm is triggered.

The alarm_general3 channel is of type alarm_general and supports the Switch item and is in the Alarm category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Thermostat mode 4

Sets the thermostat.

The thermostat_mode4 channel is of type thermostat_mode and supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Off
1 Heat
2 Cool
3 Auto
4 Aux Heat
5 Resume
6 Fan Only
7 Furnace
8 Dry Air
9 Moist Air
10 Auto Changeover
11 Heat Economy
12 Cool Economy
13 Away

Setpoint (heating) 4

Sets the thermostat setpoint.

The thermostat_setpoint4 channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Alarm 4

Indicates if an alarm is triggered.

The alarm_general4 channel is of type alarm_general and supports the Switch item and is in the Alarm category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Thermostat mode 5

Sets the thermostat.

The thermostat_mode5 channel is of type thermostat_mode and supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Off
1 Heat
2 Cool
3 Auto
4 Aux Heat
5 Resume
6 Fan Only
7 Furnace
8 Dry Air
9 Moist Air
10 Auto Changeover
11 Heat Economy
12 Cool Economy
13 Away

Setpoint (heating) 5

Sets the thermostat setpoint.

The thermostat_setpoint5 channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Alarm 5

Indicates if an alarm is triggered.

The alarm_general5 channel is of type alarm_general and supports the Switch item and is in the Alarm category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Thermostat mode 6

Sets the thermostat.

The thermostat_mode6 channel is of type thermostat_mode and supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Off
1 Heat
2 Cool
3 Auto
4 Aux Heat
5 Resume
6 Fan Only
7 Furnace
8 Dry Air
9 Moist Air
10 Auto Changeover
11 Heat Economy
12 Cool Economy
13 Away

Setpoint (heating) 6

Sets the thermostat setpoint.

The thermostat_setpoint6 channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Alarm 6

Indicates if an alarm is triggered.

The alarm_general6 channel is of type alarm_general and supports the Switch item and is in the Alarm category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Thermostat mode 7

Sets the thermostat.

The thermostat_mode7 channel is of type thermostat_mode and supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Off
1 Heat
2 Cool
3 Auto
4 Aux Heat
5 Resume
6 Fan Only
7 Furnace
8 Dry Air
9 Moist Air
10 Auto Changeover
11 Heat Economy
12 Cool Economy
13 Away

Setpoint (heating) 7

Sets the thermostat setpoint.

The thermostat_setpoint7 channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Alarm 7

Indicates if an alarm is triggered.

The alarm_general7 channel is of type alarm_general and supports the Switch item and is in the Alarm category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Thermostat mode 8

Sets the thermostat.

The thermostat_mode8 channel is of type thermostat_mode and supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Off
1 Heat
2 Cool
3 Auto
4 Aux Heat
5 Resume
6 Fan Only
7 Furnace
8 Dry Air
9 Moist Air
10 Auto Changeover
11 Heat Economy
12 Cool Economy
13 Away

Setpoint (heating) 8

Sets the thermostat setpoint.

The thermostat_setpoint8 channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Alarm 8

Indicates if an alarm is triggered.

The alarm_general8 channel is of type alarm_general and supports the Switch item and is in the Alarm category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Thermostat mode 9

Sets the thermostat.

The thermostat_mode9 channel is of type thermostat_mode and supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Off
1 Heat
2 Cool
3 Auto
4 Aux Heat
5 Resume
6 Fan Only
7 Furnace
8 Dry Air
9 Moist Air
10 Auto Changeover
11 Heat Economy
12 Cool Economy
13 Away

Setpoint (heating) 9

Sets the thermostat setpoint.

The thermostat_setpoint9 channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Alarm 9

Indicates if an alarm is triggered.

The alarm_general9 channel is of type alarm_general and supports the Switch item and is in the Alarm category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Thermostat mode 10

Sets the thermostat.

The thermostat_mode10 channel is of type thermostat_mode and supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Off
1 Heat
2 Cool
3 Auto
4 Aux Heat
5 Resume
6 Fan Only
7 Furnace
8 Dry Air
9 Moist Air
10 Auto Changeover
11 Heat Economy
12 Cool Economy
13 Away

Setpoint (heating) 10

Sets the thermostat setpoint.

The thermostat_setpoint10 channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Alarm 10

Indicates if an alarm is triggered.

The alarm_general10 channel is of type alarm_general and supports the Switch item and is in the Alarm category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Switch 11

Switch the power on and off.

The switch_binary11 channel is of type switch_binary and supports the Switch item and is in the Switch category.

Switch 12

Switch the power on and off.

The switch_binary12 channel is of type switch_binary and supports the Switch item and is in the Switch category.

Device Configuration

The following table provides a summary of the 3 configuration parameters available in the 014G0210. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Valve Type Type of Valve being controlled
2 Heat Load Strategy Set Head Load Strategy (0 = Stacking, 1 = Spreading)
3 PWM period Pulse-width modulation period

Parameter 1: Valve Type

Type of Valve being controlled Parameter 1: Valve type:

  • 0 = Normal Closed (NC) default
  • 1 = Normal Open (NO)

Mix of NC and NO types of valves is not supported

Most systems use NC valves The following option values may be configured -:

Value Description
0 NC
1 NO

The manufacturer defined default value is 0 (NC).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Heat Load Strategy

Set Head Load Strategy (0 = Stacking, 1 = Spreading) Heat load strategy:

  • 0 = Stacking (default)
  • 1 = Spreading

Stacking:

  • All endpoints where there are heat demand open at the same time at the start of each PWM period
  • Stacking is the default strategy

Spreading:

  • The opening of valves is spread over the PWM period and may stretch into the next PWM period
  • Spreading is used in effort to:
    • Spread the demand for hot water over the PWM period
    • Spread the power demand for the valves (actuators)
      • Valves from different producers require different amount of energy. The power supply in the HC has limited capacity, and may not be able to feed all the valves at the same time (more about that later in ”Current limitation”) The following option values may be configured -:
Value Description
0 Stacking (Default)
1 Spreading

The manufacturer defined default value is 0 (Stacking (Default)).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: PWM period

Pulse-width modulation period The PWM period can be set to 15, 30 or 60 seconds

Set using the Configuration Command Class on each endpoint

  • 60 minutes PWM period
    • Is the default value
    • Intended for heavy floors
      • Thick concrete floors
      • Floors where the hot water pipes lie deep
  • 15 minutes PWM period
    • Intended for light floors
      • Wood floors
      • Floors where the hot water pipes lie close to the surface

Based on the setpoint (target temperature) and the current room temperature, the HC control algorithm calculates how long portion of each PWM period the valve should be open to get to and maintain the target temperature The following option values may be configured -:

Value Description
0 15 minutes
1 30 minutes
2 60 minutes

The manufacturer defined default value is 2 (60 minutes).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The 014G0210 supports 1 association group.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. One group supported: 1 with profile "General-Life-line"

  • Lifeline for endpoints
  • Unsolicited reports:
    • Device Reset Locally Notification
    • Notification Report (Thermostat 1 only)

Association group 1 supports 1 node.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V1
COMMAND_CLASS_THERMOSTAT_MODE_V1
COMMAND_CLASS_THERMOSTAT_SETPOINT_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_MULTI_CHANNEL_V2
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V7
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_INDICATOR_V1
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2

Endpoint 1

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_THERMOSTAT_MODE_V1
COMMAND_CLASS_THERMOSTAT_SETPOINT_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V7
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_INDICATOR_V1
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2

Endpoint 2

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_THERMOSTAT_MODE_V1
COMMAND_CLASS_THERMOSTAT_SETPOINT_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V7
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_INDICATOR_V1
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2

Endpoint 3

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_THERMOSTAT_MODE_V1
COMMAND_CLASS_THERMOSTAT_SETPOINT_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V7
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_INDICATOR_V1
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2

Endpoint 4

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_THERMOSTAT_MODE_V1
COMMAND_CLASS_THERMOSTAT_SETPOINT_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V7
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_INDICATOR_V1
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2

Endpoint 5

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_THERMOSTAT_MODE_V1
COMMAND_CLASS_THERMOSTAT_SETPOINT_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V7
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_INDICATOR_V1
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2

Endpoint 6

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_THERMOSTAT_MODE_V1
COMMAND_CLASS_THERMOSTAT_SETPOINT_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V7
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_INDICATOR_V1
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2

Endpoint 7

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_THERMOSTAT_MODE_V1
COMMAND_CLASS_THERMOSTAT_SETPOINT_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V7
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_INDICATOR_V1
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2

Endpoint 8

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_THERMOSTAT_MODE_V1
COMMAND_CLASS_THERMOSTAT_SETPOINT_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V7
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_INDICATOR_V1
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2

Endpoint 9

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_THERMOSTAT_MODE_V1
COMMAND_CLASS_THERMOSTAT_SETPOINT_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V7
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_INDICATOR_V1
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2

Endpoint 10

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_THERMOSTAT_MODE_V1
COMMAND_CLASS_THERMOSTAT_SETPOINT_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V7
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_INDICATOR_V1
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2

Endpoint 11

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1

Endpoint 12

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1

Documentation Links