layout title
documentation
ZSMOKE - ZWave

{% include base.html %}

ZSMOKE Smoke Alarm

This describes the Z-Wave device ZSMOKE, manufactured by BRK Brands, Inc. with the thing type UID of brk_zsmoke_00_000.

The device is in the category of Smoke Detector, defining Smoke detectors.

ZSMOKE product image

The ZSMOKE supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

The ZSMOKE does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.

Overview

A smart home can also be a safe home. With the First Alert Smoke Detector (ZSMOKE)  you will be immediately notified at the first sign of smoke. The First Alert Smoke Detector is a Z-Wave device that emits a loud alarm when smoke is detected.

Inclusion Information

  1. Open the battery tray
  2. Hold the Test button while re-inserting the battery tray
  3. When the device beeps, release the button

Exclusion Information

  1. Open the battery tray
  2. Hold the Test button while re-inserting the battery tray
  3. When the device beeps, release the button

Wakeup Information

The ZSMOKE does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.

The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.

General Usage Information

Factory Reset:

  1. Make sure the device is powered
  2. Press and hold the test button for 10+ seconds

Channels

The following table summarises the channels available for the ZSMOKE -:

Channel Name Channel ID Channel Type Category Item Type
Alarm alarm_general alarm_general Alarm Switch
Battery Level battery-level system.battery_level Battery Number

Alarm

Indicates if an alarm is triggered.

The alarm_general channel is of type alarm_general and supports the Switch item and is in the Alarm category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The system.battery-level channel is of type system.battery-level and supports the Number item and is in the Battery category. This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.

Device Configuration

The following table provides a summary of the 1 configuration parameters available in the ZSMOKE. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Send double alarms Causes the device to send double alarm messages

Parameter 1: Send double alarms

Causes the device to send double alarm messages

The following option values may be configured -:

Value Description
0 Single Alarm
1 Double Alarm

The manufacturer defined default value is 0 (Single Alarm).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The ZSMOKE supports 1 association group.

Group 1: Group 1

Association group 1 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V1 Linked to BASIC
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1