This describes the Z-Wave device ZW099, manufactured by AEON Labs with the thing type UID of aeon_zw099_00_000.

The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.

ZW099 product image

The ZW099 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

Aeotec Smart Dimmer 6 is a low-cost Z-Wave Dimmer plug-in module specifically used to enable Z-Wave command and control (on/off/dim) of any incandescent bulbs, dimmable LED bulbs, halogen bulbs with or without transformers. It can report immediate wattage consumption or kWh energy usage over a period of time. In the event of power failure, non-volatile memory retains all programmed information relating to the unit’s operating status.

Inclusion Information

  1. Insert the Smart Dimmer to power socket, The RGB LED will be colorful gradient status.
  2. Let the primary controller into inclusion mode (If you don’t know how to do this, refer to its manual).
  3. Press the Action button.
  4. If the inclusion success, Smart Dimmer LED will be solid. Otherwise, the LED will remain colorful gradient status, in which you need to repeat the process from step 2.

Exclusion Information

  1. Insert the Smart Dimmer to power socket, The Smart Dimmer LED will be solid.
  2. Let the primary controller into remove mode (If you don’t know how to do this, refer to its manual).
  3. Press the Action button.
  4. If the remove is successful, Smart Dimmer LED will be colorful gradient status. If Smart Dimmer LED still be solid, please repeat the process from step 2.

Channels

The following table summarises the channels available for the ZW099 -:

Channel Name Channel ID Channel Type Category Item Type
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer
Power Consumption (kWh) meter_kwh meter_kwh Energy Number
Energy Consumption (watts) meter_watts meter_watts Energy Number
Night mode color color_color color_color ColorLight Color

Dimmer

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel is of type switch_dimmer and supports the Dimmer item and is in the DimmableLight category.

Power Consumption (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Energy Consumption (watts)

Indicates the instantaneous power consumption.

The meter_watts channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Night mode color

The color channel allows to control the color of a light. It is also possible to dim values and switch the light on and off.

The color_color channel is of type color_color and supports the Color item and is in the ColorLight category.

Device Configuration

The following table provides a summary of the 22 configuration parameters available in the ZW099. Detailed information on each parameter can be found in the sections below.

Param Name Description
3 Current Overload Protection Toggle current overload protection
20 Initial Load State Configure the iniital output load state after re-power on
33 RGB LED Color Test Set the RGB LED color value for testing
80 Notification on Status Change Enable notifications for Group 1 device associations.
81 LED Indicator Mode Configure the LED mode.
83 LED Color for Night Light Configure the RGB value when it is in Night light mode
84 LED Brightness Brightness level of RGB LED (0%-100%)
90 Enable Report triggered by minimal change of value Enables/disables parameter 91 and 92 (reporting minimum wattage)
91 Minimum Change to send Report (Watt) The minimum change in wattage value for a report to be sent
92 Minimum Change to send Report (%) The minimum change in wattage percentage for a report to be sent
100 Reset Report Assignments for All Groups Reset the reports to send to each report group to default values.
101 Reports for Group 1 Define which reports to send in report group 1.
102 Reports for Group 2 Define which reports to send in report group 2.
103 Reports for Group 3 Define which reports to send in report group 3.
110 Reset Report Time Intervals for All Groups Reset the reports time interval for each report group to default values.
111 Report Group 1 Time Interval The time interval of sending Report group .
112 Report Group 2 Time Interval The time interval of sending Report group 2.
113 Report Group 3 Time Interval The time interval of sending Report group 3.
200 Partner ID Partner ID (0= Aeon Labs Standard Product, 1= others).
252 Configuration Lock Enable/disable Configuration Lock
254 Device Tag Device Tag
255 Reset to Factory Default Settings Reset to Factory Default Settings
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 3: Current Overload Protection

Toggle current overload protection Output Load will be turned off automatically when the Current overrun 2.6A and the time more than 2 minutes (0=disabled, 1=enabled).  The following option values may be configured -:

Value Description
0 Disabled
1 Enabled

The manufacturer defined default value is 0 (Disabled).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 20: Initial Load State

Configure the iniital output load state after re-power on Configure the output load status after re-power on (0=last status, 1=always on, 2=always off)  The following option values may be configured -:

Value Description
0 Last Status
1 Always On
2 Always Off

The manufacturer defined default value is 0 (Last Status).

This parameter has the configuration ID config_20_1 and is of type INTEGER.

Parameter 33: RGB LED Color Test

Set the RGB LED color value for testing Set the RGB LED color value for testing (64-bit value).

  • Value1: Red value (0-255) (16-bits: 48-63)
  • Value2: Green value (0-255) (16-bits: 32-47)
  • Value3: Blue value (0-255) (16-bits: 16-31)
  • Value4: Reserved (0-255) (16-bits: 0-15)

Example Values:

  • Red = -16777216 (0xFF000000)
  • Green = 16711680 (0x00FF0000)
  • Blue = 65280 (0x0000FF00)

**NOTE:
** In OpenHAB and HABmin (or other Java software) To enter an unsigned integer value greater than 2147483647 you must convert the value to a signed 32-bit value.   Values in the range 0 to 2147483647 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_33_4 and is of type INTEGER.

Parameter 80: Notification on Status Change

Enable notifications for Group 1 device associations. Enable to send notifications to associated devices (Group 1) when the state of Smart Dimmer’s load changed (0=nothing, 1=hail CC, 2=basic CC report).  The following option values may be configured -:

Value Description
0 None
1 Hail
2 Basic CC Report

The manufacturer defined default value is 0 (None).

This parameter has the configuration ID config_80_1 and is of type INTEGER.

Parameter 81: LED Indicator Mode

Configure the LED mode. Configure the state of LED when it is in 3 modes below:

  • 0= Energy mode, the LED will follow the status (on/off) of its load.
  • 1= Momentary indicate mode, when the state of Dimmer’s load changed, The LED will follow the status (on/off) of its load, but the red LED will turn off after 5 seconds if there is no any switch action.
  • 2= Night light mode.  The following option values may be configured -:
Value Description
0 Energy Mode (Load State)
1 Momentary Mode
2 Night Light Mode

The manufacturer defined default value is 0 (Energy Mode (Load State)).

This parameter has the configuration ID config_81_1 and is of type INTEGER.

Parameter 83: LED Color for Night Light

Configure the RGB value when it is in Night light mode Configure the RGB value when it is in Night light mode. (48-bit value)

  • Value1: Red color value (0-255) (16-bits: 32-47)
  • Value2: Green color value (0-255) (16-bits: 16-31)
  • Value3: Blue color value (0-255) (16-bits: 0-15)

Example Values:

  • Blue = 255 (0x0000FF)
  • Green = 65280 (0x00FF00)
  • Red = 16711680 (0xFF0000)
  • White = 1774619 (0xFFFFFF) Values in the range 0 to 16777215 may be set.

The manufacturer defined default value is 1774619.

This parameter has the configuration ID config_83_3 and is of type INTEGER.

Parameter 84: LED Brightness

Brightness level of RGB LED (0%-100%) Configure the brightness level of RGB LED (0%-100%) when it is in Energy Mode/momentary indicate mode. (48-bit value)

  • Value1: green brightness value. (0-100) (16-bits: 32-47)
  • Value2: yellow brightness value. (0-100) (16-bits: 16-31)
  • Value3: red brightness value. (0-100) (16-bits: 0-15)

Default value is 50% brightness on all colors: 3289650 (0x323232)

  • Green=50 (0x320000)
  • Yellow=50 (0x003200)
  • Red=50 (0x000032)

Maximum value is 100% brightness on all colors: 6579300 (0x646464)

  • Green=100 (0x640000)
  • Yellow=100 (0x006400)
  • Red=100 (0x000064) Values in the range 0 to 6579300 may be set.

The manufacturer defined default value is 3289650.

This parameter has the configuration ID config_84_3 and is of type INTEGER.

Parameter 90: Enable Report triggered by minimal change of value

Enables/disables parameter 91 and 92 (reporting minimum wattage) Enables/disables parameter 91 (minimum change in wattage value) and 92 (minimum change in wattage percent).

Supported values: 1=enabled, 0=disabled The following option values may be configured -:

Value Description
0 Disabled
1 Enabled

The manufacturer defined default value is 0 (Disabled).

This parameter has the configuration ID config_90_1_wo and is of type INTEGER. This is a write only parameter.

Parameter 91: Minimum Change to send Report (Watt)

The minimum change in wattage value for a report to be sent The value here represents minimum change in wattage (in terms of wattage) for a REPORT to be sent (Valid values 0- 60000). 

Default value: 25 (watts) Values in the range 0 to 60000 may be set.

The manufacturer defined default value is 25.

This parameter has the configuration ID config_91_2 and is of type INTEGER.

Parameter 92: Minimum Change to send Report (%)

The minimum change in wattage percentage for a report to be sent The value here represents minimum change in wattage percent (in terms of percentage) for a REPORT to be sent (Valid values 0-100).

Default value: 5 (%)  Values in the range 0 to 100 may be set.

The manufacturer defined default value is 5.

This parameter has the configuration ID config_92_1 and is of type INTEGER.

Parameter 100: Reset Report Assignments for All Groups

Reset the reports to send to each report group to default values. Reset the reports to send to each report group to default values.
Set configuration parameters 101-103 to default. 
See instruction manual for details on reporting configuration. The following option values may be configured -:

Value Description
0 Do Nothing
1 Reset to Defaults

The manufacturer defined default value is 0 (Do Nothing).

This parameter has the configuration ID config_100_1_wo and is of type INTEGER. This is a write only parameter.

Parameter 101: Reports for Group 1

Define which reports to send in report group 1. Which reports need to send in Report group 1 (See flags in user manual). 

See instruction manual for details on reporting configuration. Values in the range 0 to 2147483647 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_101_4 and is of type INTEGER.

Parameter 102: Reports for Group 2

Define which reports to send in report group 2. Which reports need to send in Report group 2 (See flags in user manual). 

See instruction manual for details on reporting configuration. Values in the range 0 to 2147483647 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_102_4 and is of type INTEGER.

Parameter 103: Reports for Group 3

Define which reports to send in report group 3. Which reports need to send in Report group 3 (See flags in user manual). 

See instruction manual for details on reporting configuration. Values in the range 0 to 2147483647 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_103_4 and is of type INTEGER.

Parameter 110: Reset Report Time Intervals for All Groups

Reset the reports time interval for each report group to default values. Reset the reports to time interval for each report group to default values.
Set configuration parameters 111-113 to default. 
See instruction manual for details on reporting configuration. The following option values may be configured -:

Value Description
0 Do Nothing
1 Reset to Defaults

The manufacturer defined default value is 0 (Do Nothing).

This parameter has the configuration ID config_110_1_wo and is of type INTEGER. This is a write only parameter.

Parameter 111: Report Group 1 Time Interval

The time interval of sending Report group . The time interval of sending Report group 1 (Valid values 0x01-0x7FFFFFFF).  Values in the range 0 to 2147483647 may be set.

The manufacturer defined default value is 600.

This parameter has the configuration ID config_111_4 and is of type INTEGER.

Parameter 112: Report Group 2 Time Interval

The time interval of sending Report group 2. The time interval of sending Report group 2 (Valid values 0x01-0x7FFFFFFF).  Values in the range 0 to 2147483647 may be set.

The manufacturer defined default value is 600.

This parameter has the configuration ID config_112_4 and is of type INTEGER.

Parameter 113: Report Group 3 Time Interval

The time interval of sending Report group 3. The time interval of sending Report group 3 (Valid values 0x01-0x7FFFFFFF).  Values in the range 0 to 2147483647 may be set.

The manufacturer defined default value is 600.

This parameter has the configuration ID config_113_4 and is of type INTEGER.

Parameter 200: Partner ID

Partner ID (0= Aeon Labs Standard Product, 1= others). Partner ID
(0= Aeon Labs Standard Product, 1= others).  The following option values may be configured -:

Value Description
0 Aeon Labs Standard Product
1 Others

The manufacturer defined default value is 0 (Aeon Labs Standard Product).

This parameter has the configuration ID config_200_1 and is of type INTEGER. This is a read only parameter.

Parameter 252: Configuration Lock

Enable/disable Configuration Lock Enable/disable Configuration Locked (0 =disable, 1 = enable).  The following option values may be configured -:

Value Description
0 Disabled
1 Enabled

The manufacturer defined default value is 0 (Disabled).

This parameter has the configuration ID config_252_1 and is of type INTEGER.

Parameter 254: Device Tag

Device Tag

Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_254_2 and is of type INTEGER.

Parameter 255: Reset to Factory Default Settings

Reset to Factory Default Settings This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_255_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The ZW099 supports 2 association groups.

Group 1: Group 1

Lifeline When the state of Smart Dimmer(on/off/dim the load ) is changed:

  1. Set Configuration parameter 80 to 0:Reserved (Default).
  2. Set Configuration parameter 80 to 1:Send Hail CC.
  3. Set Configuration parameter 80 to 2: Send the Basic Report.  

Association group 1 supports 5 nodes.

Group 2: Group 2

Retransmit Forward the Basic Set, Switch Multilevel Start Level Change, Switch Multilevel Stop Level Change, Switch Multilevel Set to associated nodes in Group 2 when the Smart Dimmer receives the Basic Set, Switch Multilevel Start Level Change, Switch Multilevel Stop Level Change, Switch Multilevel Set commands from main controller.  

Association group 2 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V2 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_METER_V3
COMMAND_CLASS_SWITCH_COLOR_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
COMMAND_CLASS_MULTI_CHANNEL_V4
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
COMMAND_CLASS_CLOCK_V1
COMMAND_CLASS_HAIL_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
COMMAND_CLASS_SECURITY_V1
COMMAND_CLASS_MARK_V1

Endpoint 1

Command Class Comment
COMMAND_CLASS_SWITCH_COLOR_V1

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.