layout | title |
---|---|
documentation |
ZW096 - ZWave |
{% include base.html %}
This describes the Z-Wave device ZW096, manufactured by AEON Labs with the thing type UID of aeon_zw096_00_000
.
The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.
The ZW096 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Aeon Labs Smart Switch is a Z-Wave power binary switch device based on Z-Wave enhanced 232 slave library V6.51.06.
Its surface has the Smart RGB LEDs on, which can be used for indicating the output load status, the strength of wireless signal. You can also configure its indication colour according to your favour.
It can be included and operated in any Z-wave network with other Z-wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.
It is also a security Z-wave device and supports the Over The Air (OTA) feature for the product’s firmware upgrade.
As soon as Smart Switch is removed from a z-wave network it will be restored into default factory setting.
Reset Smart Switch to factory Default:
- Make sure the Smart Switch has been connected to the power supply.
- Press and hold the Z-wave button for 20 seconds.
- If holding time more than one second, the LED will blink faster and faster. If holding time more than 20seconds, the green LED will be on for 2 seconds and then remain colorful gradient status, it indicates reset success, otherwise please repeat step 2.
Note:
- This procedure should only be used when the primary controller is inoperable.
- Reset Smart Switch to factory default settings will: sets the Smart Switch to not in Z-Wave network state; delete the Association setting, power measure value, Scene Configuration Settings and restore the Configuration setting to the default
Add Smart Switch into a z-wave network:
- Insert the Smart Switch to power socket, The purple LED will be colorful gradient status.
- Let the primary controller into inclusion mode (If you don’t know how to do this, refer to its manual).
- Press the Action button.
- If the inclusion success, Smart Switch LED will be solid. Otherwise, the LED will remain colorful gradient status, in which you need to repeat the process from step 2.
Remove Smart Switch from a z-wave network:
- Insert the Smart Switch to power socket, The Smart Switch LED will be solid.
- Let the primary controller into remove mode (If you don’t know how to do this, refer to its manual).
- Press the Action button.
- If the remove is successful, Smart Switch LED will blink slowly. If Smart Switch LED still be solid, please repeat the process from step 2.
The following table summarises the channels available for the ZW096 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number |
Electric meter (amps) | meter_current | meter_current | Energy | Number |
Electric meter (volts) | meter_voltage | meter_voltage | Energy | Number |
Electric meter (watts) | meter_watts | meter_watts | Energy | Number |
Reset Meter | meter_reset | meter_reset | Energy | Switch |
Color | color_color | color_color | ColorLight | Color |
Reporting Interval Group 1 | config_decimal | config_decimal | Number |
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Indicates the energy consumption (kWh).
The meter_kwh
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous current consumption.
The meter_current
channel is of type meter_current
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous voltage.
The meter_voltage
channel is of type meter_voltage
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Reset the meter.
The meter_reset
channel is of type meter_reset
and supports the Switch
item and is in the Energy
category.
The color channel allows to control the color of a light. It is also possible to dim values and switch the light on and off.
The color_color
channel is of type color_color
and supports the Color
item and is in the ColorLight
category.
Change the reporting interval to reduce network traffic during off hours
Generic class for configuration parameter.
The config_decimal
channel is of type config_decimal
and supports the Number
item.
The following table provides a summary of the 26 configuration parameters available in the ZW096. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
3 | Current overload protection enable | Current overload protection enable |
20 | Output load after re-power | Configure the output load status after re‐power |
33 | RGB LED color testing | Set the RGB LED color value for testing. |
80 | Enable send to associated devices | Enable to send notifications to Group 1 |
81 | Configure LED state | Configure the state of the LED |
83 | Color in night light mode | |
83 | Blue night light color value | Blue night light color value |
83 | Green night light color value | Green night light color value |
83 | Red night light color value | Configure the RGB value when it is in Night light mode |
84 | Color in energy mode | |
84 | Green brightness in energy mode (%) | Green brightness in energy mode (%) |
84 | Yellow brightness in energy mode (%) | Yellow brightness in energy mode (%) |
84 | Red brightness in energy mode (%) | Red brightness in energy mode (%) |
90 | Enable items 91 and 92 | Enables/disables parameter 91 and 92 |
91 | Wattage Threshold | minimum change in wattage to trigger |
92 | Wattage Percent Change | minimum change in wattage percent |
100 | Set 101‐103 to default. | Set 101‐103 to default. |
101 | Values to send to group 1 | Which reports need to send in Report group 1 |
102 | Values to send to group 2 | Which reports need to send in Report group 2 |
103 | Values to send to group 3 | Which reports need to send in Report group 3 |
110 | Set 111‐113 to default. | Set 111‐113 to default. |
111 | Time interval for sending to group 1 | Group 1 automatic update interval |
112 | Time interval for sending to group 2 | Group 2 automatic update interval |
113 | Time interval for sending to group 3 | Group 3 automatic update interval |
252 | Configuration Locked | Enable/disable Configuration Locked (0 =disable, 1 = enable). |
255 | RESET | Reset the device to defaults |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Current overload protection enable Current Overload Protection. Load will be closed when the Current overrun (US: 15.5A, other country: 16.2A) and the time more than 2 minutes (0=disabled, 1=enabled). The following option values may be configured -:
Value | Description |
---|---|
0 | Disabled |
1 | Enabled |
The manufacturer defined default value is 0
(disabled).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Configure the output load status after re‐power
Configure the output load status after re-power on
(0=last status, 1=always on, 2=always off)
The following option values may be configured -:
Value | Description |
---|---|
0 | last status |
1 | always on |
2 | always off |
The manufacturer defined default value is 0
(last status).
This parameter has the configuration ID config_20_1
and is of type INTEGER
.
Set the RGB LED color value for testing. Value1: Reserved
Value2: Red value
Value3: Green value
Value4: Blue value Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_33_4_wo
and is of type INTEGER
.
This is a write only parameter.
Enable to send notifications to Group 1 Enable to send notifications to associated devices (Group 1) when the state of Micro Switch’s load changed (0=nothing, 1=hail CC, 2=basic CC report). The following option values may be configured -:
Value | Description |
---|---|
0 | nothing |
1 | hail CC |
2 | basic CC report |
The manufacturer defined default value is 0
(nothing).
This parameter has the configuration ID config_80_1
and is of type INTEGER
.
Configure the state of the LED Configure the state of LED when it is in 3 modes below:
- 0= The LED will follow the status (on/off) of its load (Energy mode).
- 1= When the state of Switch’s load changed, The LED will follow the status (on/off) of its load, but the red LED will turn off after 5 seconds if there is no any switch action (momentary indicate mode).
- 2= Night light mode. The following option values may be configured -:
Value | Description |
---|---|
0 | LED follows load |
1 | LED follows load for 5 seconds |
2 | Night light mode |
The manufacturer defined default value is 0
(LED follows load).
This parameter has the configuration ID config_81_1
and is of type INTEGER
.
This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 16777215 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_83_3
and is of type INTEGER
.
Blue night light color value Value for parameter 83, night light blue color Values in the range 0 to 255 may be set.
The manufacturer defined default value is 221
.
This parameter has the configuration ID config_83_3_000000FF
and is of type INTEGER
.
Green night light color value Green color value for parameter 83, night light mode. Values in the range 0 to 255 may be set.
The manufacturer defined default value is 160
.
This parameter has the configuration ID config_83_3_0000FF00
and is of type INTEGER
.
Configure the RGB value when it is in Night light mode
Configure the RGB value when it is in Night light mode.
Value1: Red color value
Value2: Green color value
Value3: Blue color value
defaults:
Value1=0xDD
Value2=0xA0
Value3=0xDD
Values in the range 0 to 255 may be set.
The manufacturer defined default value is 221
.
This parameter has the configuration ID config_83_3_00FF0000
and is of type INTEGER
.
This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 16777215 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_84_3
and is of type INTEGER
.
Green brightness in energy mode (%)
Configure the brightness level of RGB LED (0%-100%) when
it is in Energy Mode/momentary indicate mode.
Value1: green color value.
Value2: yellow color value.
Value3: red color value.
Values in the range 0 to 100 may be set.
The manufacturer defined default value is 50
.
This parameter has the configuration ID config_84_3_000000FF
and is of type INTEGER
.
Yellow brightness in energy mode (%)
Values in the range 0 to 100 may be set.
The manufacturer defined default value is 50
.
This parameter has the configuration ID config_84_3_0000FF00
and is of type INTEGER
.
Red brightness in energy mode (%)
Values in the range 0 to 100 may be set.
The manufacturer defined default value is 50
.
This parameter has the configuration ID config_84_3_00FF0000
and is of type INTEGER
.
Enables/disables parameter 91 and 92 Enables/disables parameter 91 and 92 below (1=enabled, 0=disabled). The following option values may be configured -:
Value | Description |
---|---|
0 | Disabled |
1 | Enabled |
The manufacturer defined default value is 1
(enabled).
This parameter has the configuration ID config_90_1
and is of type INTEGER
.
minimum change in wattage to trigger
The value here represents minimum change in wattage (in
terms of wattage) for a REPORT to be sent (Valid values 0-
60000).
Values in the range 0 to 60000 may be set.
The manufacturer defined default value is 25
.
This parameter has the configuration ID config_91_2
and is of type INTEGER
.
minimum change in wattage percent
The value here represents minimum change in wattage
percent (in terms of percentage) for a REPORT to be sent
(Valid values 0-100).
Values in the range 0 to 100 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_92_1
and is of type INTEGER
.
Set 101‐103 to default.
The following option values may be configured -:
Value | Description |
---|---|
0 | False |
1 | True |
The manufacturer defined default value is 0
(False).
This parameter has the configuration ID config_100_1_wo
and is of type INTEGER
.
This is a write only parameter.
Which reports need to send in Report group 1
The following option values may be configured -:
Value | Description |
---|---|
0 | Nothing |
1 | Voltage |
2 | Current |
4 | Wattage |
8 | kWh |
15 | All Values |
The manufacturer defined default value is 4
(Wattage).
This parameter has the configuration ID config_101_4
and is of type INTEGER
.
Which reports need to send in Report group 2
The following option values may be configured -:
Value | Description |
---|---|
0 | Nothing |
1 | Voltage |
2 | Current |
4 | Wattage |
8 | kWh |
15 | All Values |
The manufacturer defined default value is 8
(kWh).
This parameter has the configuration ID config_102_4
and is of type INTEGER
.
Which reports need to send in Report group 3
The following option values may be configured -:
Value | Description |
---|---|
0 | Nothing |
1 | Voltage |
2 | Current |
4 | Wattage |
8 | kWh |
15 | All Values |
The manufacturer defined default value is 0
(Nothing).
This parameter has the configuration ID config_103_4
and is of type INTEGER
.
Set 111‐113 to default.
The following option values may be configured -:
Value | Description |
---|---|
0 | False |
1 | True |
The manufacturer defined default value is 0
(False).
This parameter has the configuration ID config_110_1_wo
and is of type INTEGER
.
This is a write only parameter.
Group 1 automatic update interval The time interval of sending Report group 1 (Valid values 0x01-0xFFFFFFFF).
Default value is 3
Note: Only up to 0x7fffffff is currently supported Values in the range 1 to 2147483647 may be set.
The manufacturer defined default value is 3
.
This parameter has the configuration ID config_111_4
and is of type INTEGER
.
Group 2 automatic update interval The time interval of sending Report group 1 (Valid values 0x01-0xFFFFFFFF).
Default value is 600
Note: Only up to 0x7fffffff is currently supported Values in the range 1 to 2147483647 may be set.
The manufacturer defined default value is 600
.
This parameter has the configuration ID config_112_4
and is of type INTEGER
.
Group 3 automatic update interval The time interval of sending Report group 1 (Valid values 0x01-0xFFFFFFFF).
Default value is 600
Note: Only up to 0x7fffffff is currently supported Values in the range 1 to 2147483647 may be set.
The manufacturer defined default value is 600
.
This parameter has the configuration ID config_113_4
and is of type INTEGER
.
Enable/disable Configuration Locked (0 =disable, 1 = enable). Enable/disable Configuration Locked (0 =disable, 1 =enable). The following option values may be configured -:
Value | Description |
---|---|
0 | Disabled |
1 | Enabled |
The manufacturer defined default value is 0
(disabled).
This parameter has the configuration ID config_252_1
and is of type INTEGER
.
Reset the device to defaults Reset configuration set up to default setting.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 1 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_255_1_wo
and is of type INTEGER
.
This is a write only parameter.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZW096 supports 2 association groups.
load notification type (lifeline) When the state of Smart Switch (turn on/off the load ) is changed:
- Set Configuration parameter 80 to 0 Reserved (Default).
- Set Configuration parameter 80 to 1 Send Hail CC.
- Set Configuration parameter 80 to 2: Send the Basic Report.
Association group 1 supports 5 nodes.
forwarding basic set (retransmit) Forward the Basic Set, Switch Binary Set to associated nodes in Group 2 when the Smart Switch receives the Basic Set, Switch Binary Set commands from main controller.
Association group 2 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_METER_V3 | |
COMMAND_CLASS_SWITCH_COLOR_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.