ZW096 Smart Switch 6

This describes the Z-Wave device ZW096, manufactured by AEON Labs with the thing type UID of aeon_zw096_00_000.

The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.

ZW096 product image

The ZW096 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

Aeon Labs Smart Switch is a Z-Wave power binary switch device based on Z-Wave enhanced 232 slave library V6.51.06.

Its surface has the Smart RGB LEDs on, which can be used for indicating the output load status, the strength of wireless signal. You can also configure its indication colour according to your favour.

It can be included and operated in any Z-wave network with other Z-wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.

It is also a security Z-wave device and supports the Over The Air (OTA) feature for the product’s firmware upgrade.
As soon as Smart Switch is removed from a z-wave network it will be restored into default factory setting.

Reset Smart Switch to factory Default:

  1. Make sure the Smart Switch has been connected to the power supply.
  2. Press and hold the Z-wave button for 20 seconds.
  3. If holding time more than one second, the LED will blink faster and faster. If holding time more than 20seconds, the green LED will be on for 2 seconds and then remain colorful gradient status, it indicates reset success, otherwise please repeat step 2.

Note:

  1. This procedure should only be used when the primary controller is inoperable.
  2. Reset Smart Switch to factory default settings will: sets the Smart Switch to not in Z-Wave network state; delete the Association setting, power measure value, Scene Configuration Settings and restore the Configuration setting to the default

Inclusion Information

Add Smart Switch into a z-wave network:

  1. Insert the Smart Switch to power socket, The purple LED will be colorful gradient status.
  2. Let the primary controller into inclusion mode (If you don’t know how to do this, refer to its manual).
  3. Press the Action button.
  4. If the inclusion success, Smart Switch LED will be solid. Otherwise, the LED will remain colorful gradient status, in which you need to repeat the process from step 2.

Exclusion Information

Remove Smart Switch from a z-wave network:

  1. Insert the Smart Switch to power socket, The Smart Switch LED will be solid.
  2. Let the primary controller into remove mode (If you don’t know how to do this, refer to its manual).
  3. Press the Action button.
  4. If the remove is successful, Smart Switch LED will blink slowly. If Smart Switch LED still be solid, please repeat the process from step 2.

Channels

The following table summarises the channels available for the ZW096 -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (amps) meter_current meter_current Energy Number
Electric meter (volts) meter_voltage meter_voltage Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number
Reset Meter meter_reset meter_reset Energy Switch
Color color_color color_color ColorLight Color
Reporting Interval Group 1 config_decimal config_decimal Number

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (amps)

Indicates the instantaneous current consumption.

The meter_current channel is of type meter_current and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (volts)

Indicates the instantaneous voltage.

The meter_voltage channel is of type meter_voltage and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Reset Meter

Reset the meter.

The meter_reset channel is of type meter_reset and supports the Switch item and is in the Energy category.

Color

The color channel allows to control the color of a light. It is also possible to dim values and switch the light on and off.

The color_color channel is of type color_color and supports the Color item and is in the ColorLight category.

Reporting Interval Group 1

Change the reporting interval to reduce network traffic during off hours

Generic class for configuration parameter.

The config_decimal channel is of type config_decimal and supports the Number item.

Device Configuration

The following table provides a summary of the 26 configuration parameters available in the ZW096. Detailed information on each parameter can be found in the sections below.

Param Name Description
3 Current overload protection enable Current overload protection enable
20 Output load after re-power Configure the output load status after re‐power
33 RGB LED color testing Set the RGB LED color value for testing.
80 Enable send to associated devices Enable to send notifications to Group 1
81 Configure LED state Configure the state of the LED
83 Color in night light mode
83 Blue night light color value Blue night light color value
83 Green night light color value Green night light color value
83 Red night light color value Configure the RGB value when it is in Night light mode
84 Color in energy mode
84 Green brightness in energy mode (%) Green brightness in energy mode (%)
84 Yellow brightness in energy mode (%) Yellow brightness in energy mode (%)
84 Red brightness in energy mode (%) Red brightness in energy mode (%)
90 Enable items 91 and 92 Enables/disables parameter 91 and 92
91 Wattage Threshold minimum change in wattage to trigger
92 Wattage Percent Change minimum change in wattage percent
100 Set 101‐103 to default. Set 101‐103 to default.
101 Values to send to group 1 Which reports need to send in Report group 1
102 Values to send to group 2 Which reports need to send in Report group 2
103 Values to send to group 3 Which reports need to send in Report group 3
110 Set 111‐113 to default. Set 111‐113 to default.
111 Time interval for sending to group 1 Group 1 automatic update interval
112 Time interval for sending to group 2 Group 2 automatic update interval
113 Time interval for sending to group 3 Group 3 automatic update interval
252 Configuration Locked Enable/disable Configuration Locked (0 =disable, 1 = enable).
255 RESET Reset the device to defaults
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 3: Current overload protection enable

Current overload protection enable Current Overload Protection. Load will be closed when the Current overrun (US: 15.5A, other country: 16.2A) and the time more than 2 minutes (0=disabled, 1=enabled). The following option values may be configured -:

Value Description
0 Disabled
1 Enabled

The manufacturer defined default value is 0 (disabled).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 20: Output load after re-power

Configure the output load status after re‐power Configure the output load status after re-power on
(0=last status, 1=always on, 2=always off) The following option values may be configured -:

Value Description
0 last status
1 always on
2 always off

The manufacturer defined default value is 0 (last status).

This parameter has the configuration ID config_20_1 and is of type INTEGER.

Parameter 33: RGB LED color testing

Set the RGB LED color value for testing. Value1: Reserved

Value2: Red value

Value3: Green value

Value4: Blue value Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_33_4_wo and is of type INTEGER. This is a write only parameter.

Parameter 80: Enable send to associated devices

Enable to send notifications to Group 1 Enable to send notifications to associated devices (Group 1) when the state of Micro Switch’s load changed (0=nothing, 1=hail CC, 2=basic CC report). The following option values may be configured -:

Value Description
0 nothing
1 hail CC
2 basic CC report

The manufacturer defined default value is 0 (nothing).

This parameter has the configuration ID config_80_1 and is of type INTEGER.

Parameter 81: Configure LED state

Configure the state of the LED Configure the state of LED when it is in 3 modes below:

  • 0= The LED will follow the status (on/off) of its load (Energy mode).
  • 1= When the state of Switch’s load changed, The LED will follow the status (on/off) of its load, but the red LED will turn off after 5 seconds if there is no any switch action (momentary indicate mode).
  • 2= Night light mode. The following option values may be configured -:
Value Description
0 LED follows load
1 LED follows load for 5 seconds
2 Night light mode

The manufacturer defined default value is 0 (LED follows load).

This parameter has the configuration ID config_81_1 and is of type INTEGER.

Parameter 83: Color in night light mode

This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 16777215 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_83_3 and is of type INTEGER.

Parameter 83: Blue night light color value

Blue night light color value Value for parameter 83, night light blue color Values in the range 0 to 255 may be set.

The manufacturer defined default value is 221.

This parameter has the configuration ID config_83_3_000000FF and is of type INTEGER.

Parameter 83: Green night light color value

Green night light color value Green color value for parameter 83, night light mode. Values in the range 0 to 255 may be set.

The manufacturer defined default value is 160.

This parameter has the configuration ID config_83_3_0000FF00 and is of type INTEGER.

Parameter 83: Red night light color value

Configure the RGB value when it is in Night light mode Configure the RGB value when it is in Night light mode.
Value1: Red color value
Value2: Green color value
Value3: Blue color value

defaults:

Value1=0xDD
Value2=0xA0
Value3=0xDD Values in the range 0 to 255 may be set.

The manufacturer defined default value is 221.

This parameter has the configuration ID config_83_3_00FF0000 and is of type INTEGER.

Parameter 84: Color in energy mode

This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 16777215 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_84_3 and is of type INTEGER.

Parameter 84: Green brightness in energy mode (%)

Green brightness in energy mode (%) Configure the brightness level of RGB LED (0%-100%) when
it is in Energy Mode/momentary indicate mode.
Value1: green color value.
Value2: yellow color value.
Value3: red color value. Values in the range 0 to 100 may be set.

The manufacturer defined default value is 50.

This parameter has the configuration ID config_84_3_000000FF and is of type INTEGER.

Parameter 84: Yellow brightness in energy mode (%)

Yellow brightness in energy mode (%)

Values in the range 0 to 100 may be set.

The manufacturer defined default value is 50.

This parameter has the configuration ID config_84_3_0000FF00 and is of type INTEGER.

Parameter 84: Red brightness in energy mode (%)

Red brightness in energy mode (%)

Values in the range 0 to 100 may be set.

The manufacturer defined default value is 50.

This parameter has the configuration ID config_84_3_00FF0000 and is of type INTEGER.

Parameter 90: Enable items 91 and 92

Enables/disables parameter 91 and 92 Enables/disables parameter 91 and 92 below (1=enabled, 0=disabled). The following option values may be configured -:

Value Description
0 Disabled
1 Enabled

The manufacturer defined default value is 1 (enabled).

This parameter has the configuration ID config_90_1 and is of type INTEGER.

Parameter 91: Wattage Threshold

minimum change in wattage to trigger The value here represents minimum change in wattage (in
terms of wattage) for a REPORT to be sent (Valid values 0-
60000). Values in the range 0 to 60000 may be set.

The manufacturer defined default value is 25.

This parameter has the configuration ID config_91_2 and is of type INTEGER.

Parameter 92: Wattage Percent Change

minimum change in wattage percent The value here represents minimum change in wattage
percent (in terms of percentage) for a REPORT to be sent
(Valid values 0-100). Values in the range 0 to 100 may be set.

The manufacturer defined default value is 5.

This parameter has the configuration ID config_92_1 and is of type INTEGER.

Parameter 100: Set 101‐103 to default.

Set 101‐103 to default.

The following option values may be configured -:

Value Description
0 False
1 True

The manufacturer defined default value is 0 (False).

This parameter has the configuration ID config_100_1_wo and is of type INTEGER. This is a write only parameter.

Parameter 101: Values to send to group 1

Which reports need to send in Report group 1

The following option values may be configured -:

Value Description
0 Nothing
1 Voltage
2 Current
4 Wattage
8 kWh
15 All Values

The manufacturer defined default value is 4 (Wattage).

This parameter has the configuration ID config_101_4 and is of type INTEGER.

Parameter 102: Values to send to group 2

Which reports need to send in Report group 2

The following option values may be configured -:

Value Description
0 Nothing
1 Voltage
2 Current
4 Wattage
8 kWh
15 All Values

The manufacturer defined default value is 8 (kWh).

This parameter has the configuration ID config_102_4 and is of type INTEGER.

Parameter 103: Values to send to group 3

Which reports need to send in Report group 3

The following option values may be configured -:

Value Description
0 Nothing
1 Voltage
2 Current
4 Wattage
8 kWh
15 All Values

The manufacturer defined default value is 0 (Nothing).

This parameter has the configuration ID config_103_4 and is of type INTEGER.

Parameter 110: Set 111‐113 to default.

Set 111‐113 to default.

The following option values may be configured -:

Value Description
0 False
1 True

The manufacturer defined default value is 0 (False).

This parameter has the configuration ID config_110_1_wo and is of type INTEGER. This is a write only parameter.

Parameter 111: Time interval for sending to group 1

Group 1 automatic update interval The time interval of sending Report group 1 (Valid values 0x01-0xFFFFFFFF).

Default value is 3

Note: Only up to 0x7fffffff is currently supported Values in the range 1 to 2147483647 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_111_4 and is of type INTEGER.

Parameter 112: Time interval for sending to group 2

Group 2 automatic update interval The time interval of sending Report group 1 (Valid values 0x01-0xFFFFFFFF).

Default value is 600

Note: Only up to 0x7fffffff is currently supported Values in the range 1 to 2147483647 may be set.

The manufacturer defined default value is 600.

This parameter has the configuration ID config_112_4 and is of type INTEGER.

Parameter 113: Time interval for sending to group 3

Group 3 automatic update interval The time interval of sending Report group 1 (Valid values 0x01-0xFFFFFFFF).

Default value is 600

Note: Only up to 0x7fffffff is currently supported Values in the range 1 to 2147483647 may be set.

The manufacturer defined default value is 600.

This parameter has the configuration ID config_113_4 and is of type INTEGER.

Parameter 252: Configuration Locked

Enable/disable Configuration Locked (0 =disable, 1 = enable). Enable/disable Configuration Locked (0 =disable, 1 =enable). The following option values may be configured -:

Value Description
0 Disabled
1 Enabled

The manufacturer defined default value is 0 (disabled).

This parameter has the configuration ID config_252_1 and is of type INTEGER.

Parameter 255: RESET

Reset the device to defaults Reset configuration set up to default setting.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 1 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_255_1_wo and is of type INTEGER. This is a write only parameter.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The ZW096 supports 2 association groups.

Group 1: Group 1

load notification type (lifeline) When the state of Smart Switch (turn on/off the load ) is changed:

  1. Set Configuration parameter 80 to 0 Reserved (Default).
  2. Set Configuration parameter 80 to 1 Send Hail CC.
  3. Set Configuration parameter 80 to 2: Send the Basic Report.

Association group 1 supports 5 nodes.

Group 2: Group 2

forwarding basic set (retransmit) Forward the Basic Set, Switch Binary Set to associated nodes in Group 2 when the Smart Switch receives the Basic Set, Switch Binary Set commands from main controller.

Association group 2 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_METER_V3
COMMAND_CLASS_SWITCH_COLOR_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1

Documentation Links