layout | title |
---|---|
documentation |
ZW089 - ZWave |
{% include base.html %}
This describes the Z-Wave device ZW089, manufactured by AEON Labs with the thing type UID of aeon_zw089_00_000
.
The device is in the category of Door, defining Door sensors.
The ZW089 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The ZW089 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.
Aeon Labs Recessed Door Sensor Gen5 is a door detector that can detect the state of the door's open/close.
- Power on the Recessed Door Sensor Gen5.
- Let the primary controller into inclusion mode (If you don’t know how to do this, refer to its manual).
- Press the Z‐Wave button.
- If the inclusion is success, Recessed Door Sensor Gen5’s LED will be kept turning on for 10 minutes. If the LED still blinks slowly, in which you need to repeat the process from step 2.
- Power on the Recessed Door Sensor Gen5.
- Let the primary controller into exclusion mode (If you don’t know how to do this, refer to its manual).
- Press the Z‐Wave button.
- If the exclusion is success, Recessed Door Sensor Gen5’s LED will blink slowly. If LED still be solid status for 3 seconds after you short press the Z‐Wave button, in which you need to repeat the process from step 2
The ZW089 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.
The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
Press and hold the Z‐wave Button for 6 seconds. It will sleep after you released the z‐wave button for 10 seconds, or sleep right away when received the Wake Up No More Information and then the led will turn off.
The following table summarises the channels available for the ZW089 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Door Status | sensor_door | sensor_door | Door | Contact |
Alarm | alarm_general | alarm_general | Alarm | Switch |
Battery Level | battery-level | system.battery_level | Battery | Number |
Indicates if the door/window is open or closed.
The sensor_door
channel is of type sensor_door
and supports the Contact
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Contact
item type -:
Value | Label |
---|---|
OPEN | Open |
CLOSED | Closed |
Indicates if an alarm is triggered.
The alarm_general
channel is of type alarm_general
and supports the Switch
item and is in the Alarm
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The system.battery-level
channel is of type system.battery-level
and supports the Number
item and is in the Battery
category.
This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.
The following table provides a summary of the 8 configuration parameters available in the ZW089. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Send Sensor binary report on open/close events | |
3 | Send Basic Set on open/close event | |
101 | Low battery voltage check | low battery check when voltage is less than warn voltage |
111 | Low battery voltage check time | Minimum battery low check Interval time is 4 minutes |
121 | Configuration Value 4(LSB) SENSOR BINARY | Configuration Value 4(LSB) SENSOR BINARY |
121 | Config value 3 - BASIC SET | Set BASIC SET reporting |
252 | Permit other configurations | Lock or Unlock other configuration set function |
255 | Reset to default | Reset to the default configuration |
Wakeup Interval | Sets the interval at which the device will accept commands from the controller | |
Wakeup Node | Sets the node ID of the device to receive the wakeup notifications |
The following option values may be configured -:
Value | Description |
---|---|
0 | On for opened, Off for closed |
1 | Off for opened, On for closed |
The manufacturer defined default value is 0
(On for opened, Off for closed).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | On for opened, Off for closed |
1 | Off for opened, On for closed |
The manufacturer defined default value is 0
(On for opened, Off for closed).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
low battery check when voltage is less than warn voltage Enable/disable the function of low battery checking, when the current voltage is less than the warning voltage, it will send the Battery Low Warning Report. (00==Disable, 1==Enable) The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_101_1
and is of type INTEGER
.
Minimum battery low check Interval time is 4 minutes The Interval time of low battery checking (0~0xFFFFFFFF seconds). The minimum unit of interval time is 4 minutes. If the value is set to 1 minute, the interval time will be 4 minutes. The same is if the value is set to 7 minutes, the interval time will be 8 minutes. Note: 1, This parameter only will be activated after the function of low battery checking (parameter 101) is enabled. 2, Recessed Door Sensor also will check the current battery voltage when it was wake up as other ways (e. g. the Z ‐ Wave button trigger, magnet switch trigger, and the Wake Up Interval Set timeout trigger) after the function of low battery checking (parameter 101) is enabled. Values in the range 240 to 2147483647 may be set.
The manufacturer defined default value is 86640
.
This parameter has the configuration ID config_111_4
and is of type INTEGER
.
Configuration Value 4(LSB) SENSOR BINARY set to 16 for sensor binary (recommended)
set to 0 for factory default The following option values may be configured -:
Value | Description |
---|---|
0 | disable SENSOR BINARY (factory) |
16 | enable SENSOR BINARY |
The manufacturer defined default value is 0
(disable SENSOR BINARY (factory)).
This parameter has the configuration ID config_121_4_000000FF
and is of type INTEGER
.
Set BASIC SET reporting Set to 1 for BASIC SET report (factory default)
Set to 0 to disable BASIC SET report The following option values may be configured -:
Value | Description |
---|---|
0 | do not send BASIC SET |
1 | send BASIC SET (factory default) |
The manufacturer defined default value is 1
(send BASIC SET (factory default)).
This parameter has the configuration ID config_121_4_0000FF00
and is of type INTEGER
.
Lock or Unlock other configuration set function
The following option values may be configured -:
Value | Description |
---|---|
0 | Unlock |
1 | Lock |
The manufacturer defined default value is 0
(Unlock).
This parameter has the configuration ID config_252_1
and is of type INTEGER
.
Reset to the default configuration Reset all configuration parameters (except the parameter 254) to default settingsThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_255_1_wo
and is of type INTEGER
.
This is a write only parameter.
The wakeup interval sets the period at which the device will listen for messages from the controller. This is required for battery devices that sleep most of the time in order to conserve battery life. The device will wake up at this interval and send a message to the controller to tell it that it can accept messages - after a few seconds, it will go back to sleep if there is no further communications.
This setting is defined in seconds. It is advisable not to set this interval too short or it could impact battery life. A period of 1 hour (3600 seconds) is suitable in most instances.
Note that this setting does not affect the devices ability to send sensor data, or notification events.
This parameter has the configuration ID wakeup_interval
and is of type INTEGER
.
When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address. In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.
This parameter has the configuration ID wakeup_node
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZW089 supports 2 association groups.
Association group 1 supports 5 nodes.
Association group 2 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_WAKE_UP_V2 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.