This describes the Z-Wave device ZW075, manufactured by AEON Labs with the thing type UID of aeon_zw075_00_000
.
This version of the device is limited to firmware versions below 3.255
The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.
The ZW075 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Smart Energy Switch 3rd Edition
- Remotely turn connected device on/off to save electricity
- Reports wattage consumption or kwh energy usage
- Small size to help minimize blocking of other AC outlets
Put your controller into inclusion mode. Press the Action Button on your switch. If your switch has been successfully linked to your network, its LED will no longer blink. If the linking was unsuccessful the LED will continue to blink.
Put your controller into exclusion mode. Press the Action Button on your switch. If your switch has been successfully removed from your network, its LED will blink. If the removal was unsuccessful its LED will not blink.
The following table summarises the channels available for the ZW075 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Electric meter (amps) | meter_current | meter_current | Energy | Number |
Electric meter (volts) | meter_voltage | meter_voltage | Energy | Number |
Electric meter (watts) | meter_watts | meter_watts | Energy | Number |
Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number |
Reset Meter | meter_reset | meter_reset | Energy | Switch |
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Indicates the instantaneous current consumption.
The meter_current
channel is of type meter_current
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous voltage.
The meter_voltage
channel is of type meter_voltage
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Reset the meter.
The meter_reset
channel is of type meter_reset
and supports the Switch
item and is in the Energy
category.
The following table provides a summary of the 16 configuration parameters available in the ZW075. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
2 | Blinking Behaviour | The LSB defines the total time the device need to blink. |
3 | Current Overload Protection | Load will be closed when the Current over runs |
20 | Output Load Status | Configure the output load status after re‐power on. |
80 | Notification on Status Change | Enable device to send notification to associated devices |
81 | Configure the state of red LED | Enable the device to send notification to associated devices (Group 1) |
90 | Enables/disables parameter 91/92 | Enable/Disable automated sending of report triggered by minimal change of value. |
91 | Minimum Change to send Report (Watt) | The value represents the minimum change in Wattage for a Report to be sent. |
92 | Minimum Change to send Report (%) | Minimum change in Wattage Percent for a report to be sent. |
100 | Set 101‐103 to default | Enable/Disable automated report triggered by min. change of value. |
101 | Report type to send to Group 1 | The value is a combination number |
102 | Report type to send to Group 2 | The value is a combination number |
103 | Report type to send to Group 3 | The value is a combination number |
111 | Interval to send out reports to Group 1 | Time Interval to send reports to Group 1 |
112 | Interval to send out reports of group 2 | Time interval to send reports of group 2 |
113 | Interval to send out reports of group 3 | Time interval when report of Reporting Group 3 is sent. |
252 | Enable/disable Configuration Lock | |
Wakeup Interval | Sets the interval at which the device will accept commands from the controller | |
Wakeup Node | Sets the node ID of the device to receive the wakeup notifications | |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
The LSB defines the total time the device need to blink. The LSB defines the total time the device need to blink. The value if set in seconds. 1 - 255 The MSB defines the on/off interval of the blinking. The unit is 0.1 s. This is a double byte value. Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_2_2
and is of type INTEGER
.
Load will be closed when the Current over runs Load will be closed when the Current over runs (US: 15.5A, other country: 16.2A) for more than 2 minutes. The following option values may be configured -:
Value | Description |
---|---|
0 | Disabled |
1 | Enabled |
The manufacturer defined default value is 0
(Disabled).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Configure the output load status after re‐power on.
The following option values may be configured -:
Value | Description |
---|---|
0 | Last Status |
1 | Always On |
2 | Always Off |
The manufacturer defined default value is 0
(Last Status).
This parameter has the configuration ID config_20_1
and is of type INTEGER
.
Enable device to send notification to associated devices Enable device to send notification to associated devices (Group 1) when the state of Micro Smart Switch's load changed. DEFAULT is Disable The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Hail CC Sent |
2 | Basic CC Report Sent |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_80_1
and is of type INTEGER
.
Enable the device to send notification to associated devices (Group 1) Enable the device to send notification to associated devices (Group 1) when the state of the Micro Smart Switch's load changed The following option values may be configured -:
Value | Description |
---|---|
0 | The LED will follow the status of its load |
1 | Switch off after 5 seconds |
The manufacturer defined default value is 0
(The LED will follow the status of its load).
This parameter has the configuration ID config_81_1
and is of type INTEGER
.
Enable/Disable automated sending of report triggered by minimal change of value. Users, who want a more constant monitoring of power consumption should set this value to 1. The reporting period is by default quite long ( approx. 35minutes) The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_90_1
and is of type INTEGER
.
The value represents the minimum change in Wattage for a Report to be sent. Range is 0 - 32000 Values in the range 0 to 32000 may be set.
The manufacturer defined default value is 25
.
This parameter has the configuration ID config_91_2
and is of type INTEGER
.
Minimum change in Wattage Percent for a report to be sent. The value represents the minimum change in Wattage Percent for a report to be sent. Range is 0 to 100% Values in the range 0 to 100 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_92_1
and is of type INTEGER
.
Enable/Disable automated report triggered by min. change of value. Enable/Disable automated sending of report triggered by minimal change of value. The following option values may be configured -:
Value | Description |
---|---|
0 | Set to Default |
1 | Nothing |
The manufacturer defined default value is 0
(Set to Default).
This parameter has the configuration ID config_100_1
and is of type INTEGER
.
The value is a combination number The value is a combination number made up of the sum of the values for the individual parameters.
The parameters have the values: KWH=8, Wattage=4, Current=2, Voltage=1.
Therefore if you want all parameters sending regular r Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 4
.
This parameter has the configuration ID config_101_4
and is of type INTEGER
.
The value is a combination number The value is a combination number made up of the sum of the values for the individual parameters.
The parameters have the values: KWH=8, Wattage=4, Current=2, Voltage=1.
Therefore if you want all parameters sending regular re Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 8
.
This parameter has the configuration ID config_102_4
and is of type INTEGER
.
The value is a combination number
The value is a combination number
made up of the sum of the values for the individual parameters.
The parameters have the values: KWH=8, Wattage=4, Current=2, Voltage=1.
Therefore if you want all parameters sending regular re
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_103_4
and is of type INTEGER
.
Time Interval to send reports to Group 1 Defines the time interval when the defined report of Reporting Group 1 is sent out.
0 s - 65535 s - Interval Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 720
.
This parameter has the configuration ID config_111_4
and is of type INTEGER
.
Time interval to send reports of group 2 Defines the time interval when the defined report of Reporting Group 2 is sent out.
0 s - 65535 s - Interval Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 720
.
This parameter has the configuration ID config_112_4
and is of type INTEGER
.
Time interval when report of Reporting Group 3 is sent. Defines the time interval when the defined report of Reporting Group 3 is sent out.
0 s - 65535 s - Interval Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 65535
.
This parameter has the configuration ID config_113_4
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_252_1
and is of type INTEGER
.
The wakeup interval sets the period at which the device will listen for messages from the controller. This is required for battery devices that sleep most of the time in order to conserve battery life. The device will wake up at this interval and send a message to the controller to tell it that it can accept messages - after a few seconds, it will go back to sleep if there is no further communications.
This setting is defined in seconds. It is advisable not to set this interval too short or it could impact battery life. A period of 1 hour (3600 seconds) is suitable in most instances.
Note that this setting does not affect the devices ability to send sensor data, or notification events.
This parameter has the configuration ID wakeup_interval
and is of type INTEGER
.
When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address. In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.
This parameter has the configuration ID wakeup_node
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZW075 supports 2 association groups.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.
Association group 1 supports 5 nodes.
Association group 2 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_APPLICATION_STATUS_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_SCENE_ACTIVATION_V1 | |
COMMAND_CLASS_SENSOR_BINARY_V1 | |
COMMAND_CLASS_METER_V3 | |
COMMAND_CLASS_CRC_16_ENCAP_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_WAKE_UP_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |