ZW075 Smart Energy Switch 3rd Edition

This describes the Z-Wave device ZW075, manufactured by AEON Labs with the thing type UID of aeon_zw075_00_000. This version of the device is limited to firmware versions below 3.255

The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.

ZW075 product image

The ZW075 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

Smart Energy Switch 3rd Edition

  • Remotely turn connected device on/off to save electricity
  • Reports wattage consumption or kwh energy usage
  • Small size to help minimize blocking of other AC outlets

Inclusion Information

Put your controller into inclusion mode. Press the Action Button on your switch. If your switch has been successfully linked to your network, its LED will no longer blink. If the linking was unsuccessful the LED will continue to blink.

Exclusion Information

Put your controller into exclusion mode. Press the Action Button on your switch. If your switch has been successfully removed from your network, its LED will blink. If the removal was unsuccessful its LED will not blink.

Channels

The following table summarises the channels available for the ZW075 -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch
Electric meter (amps) meter_current meter_current Energy Number
Electric meter (volts) meter_voltage meter_voltage Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Reset Meter meter_reset meter_reset Energy Switch

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Electric meter (amps)

Indicates the instantaneous current consumption.

The meter_current channel is of type meter_current and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (volts)

Indicates the instantaneous voltage.

The meter_voltage channel is of type meter_voltage and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Reset Meter

Reset the meter.

The meter_reset channel is of type meter_reset and supports the Switch item and is in the Energy category.

Device Configuration

The following table provides a summary of the 16 configuration parameters available in the ZW075. Detailed information on each parameter can be found in the sections below.

Param Name Description
2 Blinking Behaviour The LSB defines the total time the device need to blink.
3 Current Overload Protection Load will be closed when the Current over runs
20 Output Load Status Configure the output load status after re‐power on.
80 Notification on Status Change Enable device to send notification to associated devices
81 Configure the state of red LED Enable the device to send notification to associated devices (Group 1)
90 Enables/disables parameter 91/92 Enable/Disable automated sending of report triggered by minimal change of value.
91 Minimum Change to send Report (Watt) The value represents the minimum change in Wattage for a Report to be sent.
92 Minimum Change to send Report (%) Minimum change in Wattage Percent for a report to be sent.
100 Set 101‐103 to default  Enable/Disable automated report triggered by min. change of value.
101 Report type to send to Group 1 The value is a combination number
102 Report type to send to Group 2 The value is a combination number
103 Report type to send to Group 3 The value is a combination number
111 Interval to send out reports to Group 1 Time Interval to send reports to Group 1
112 Interval to send out reports of group 2 Time interval to send reports of group 2
113 Interval to send out reports of group 3 Time interval when report of Reporting Group 3 is sent.
252 Enable/disable Configuration Lock
Wakeup Interval Sets the interval at which the device will accept commands from the controller
Wakeup Node Sets the node ID of the device to receive the wakeup notifications
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 2: Blinking Behaviour

The LSB defines the total time the device need to blink. The LSB defines the total time the device need to blink. The value if set in seconds. 1 - 255 The MSB defines the on/off interval of the blinking. The unit is 0.1 s. This is a double byte value. Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_2_2 and is of type INTEGER.

Parameter 3: Current Overload Protection

Load will be closed when the Current over runs  Load will be closed when the Current over runs (US: 15.5A, other country: 16.2A) for more than 2 minutes. The following option values may be configured -:

Value Description
0 Disabled
1 Enabled

The manufacturer defined default value is 0 (Disabled).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 20: Output Load Status

Configure the output load status after re‐power on.

The following option values may be configured -:

Value Description
0 Last Status
1 Always On
2 Always Off

The manufacturer defined default value is 0 (Last Status).

This parameter has the configuration ID config_20_1 and is of type INTEGER.

Parameter 80: Notification on Status Change

Enable device to send notification to associated devices Enable device to send notification to associated devices (Group 1) when the state of Micro Smart Switch's load changed. DEFAULT is Disable The following option values may be configured -:

Value Description
0 Disable
1 Hail CC Sent
2 Basic CC Report Sent

The manufacturer defined default value is 0 (Disable).

This parameter has the configuration ID config_80_1 and is of type INTEGER.

Parameter 81: Configure the state of red LED

Enable the device to send notification to associated devices (Group 1) Enable the device to send notification to associated devices (Group 1) when the state of the Micro Smart Switch's load changed The following option values may be configured -:

Value Description
0 The LED will follow the status of its load
1 Switch off after 5 seconds

The manufacturer defined default value is 0 (The LED will follow the status of its load).

This parameter has the configuration ID config_81_1 and is of type INTEGER.

Parameter 90: Enables/disables parameter 91/92

Enable/Disable automated sending of report triggered by minimal change of value. Users, who want a more constant monitoring of power consumption should set this value to 1. The reporting period is by default quite long ( approx. 35minutes) The following option values may be configured -:

Value Description
0 Disable
1 Enable

The manufacturer defined default value is 0 (Disable).

This parameter has the configuration ID config_90_1 and is of type INTEGER.

Parameter 91: Minimum Change to send Report (Watt)

The value represents the minimum change in Wattage for a Report to be sent.  Range is 0 - 32000 Values in the range 0 to 32000 may be set.

The manufacturer defined default value is 25.

This parameter has the configuration ID config_91_2 and is of type INTEGER.

Parameter 92: Minimum Change to send Report (%)

Minimum change in Wattage Percent for a report to be sent. The value represents the minimum change in Wattage Percent for a report to be sent. Range is 0 to 100% Values in the range 0 to 100 may be set.

The manufacturer defined default value is 5.

This parameter has the configuration ID config_92_1 and is of type INTEGER.

Parameter 100: Set 101‐103 to default

 Enable/Disable automated report triggered by min. change of value.  Enable/Disable automated sending of report triggered by minimal change of value. The following option values may be configured -:

Value Description
0 Set to Default
1 Nothing

The manufacturer defined default value is 0 (Set to Default).

This parameter has the configuration ID config_100_1 and is of type INTEGER.

Parameter 101: Report type to send to Group 1

The value is a combination number The value is a combination number made up of the sum of the values for the individual parameters.

The parameters have the values: KWH=8, Wattage=4, Current=2, Voltage=1.

Therefore if you want all parameters sending regular r Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 4.

This parameter has the configuration ID config_101_4 and is of type INTEGER.

Parameter 102: Report type to send to Group 2

The value is a combination number The value is a combination number made up of the sum of the values for the individual parameters.

The parameters have the values: KWH=8, Wattage=4, Current=2, Voltage=1.

 Therefore if you want all parameters sending regular re Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 8.

This parameter has the configuration ID config_102_4 and is of type INTEGER.

Parameter 103: Report type to send to Group 3

The value is a combination number The value is a combination number
made up of the sum of the values for the individual parameters.
The parameters have the values: KWH=8, Wattage=4, Current=2, Voltage=1.
Therefore if you want all parameters sending regular re Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_103_4 and is of type INTEGER.

Parameter 111: Interval to send out reports to Group 1

Time Interval to send reports to Group 1 Defines the time interval when the defined report of Reporting Group 1 is sent out.

0 s - 65535 s - Interval Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 720.

This parameter has the configuration ID config_111_4 and is of type INTEGER.

Parameter 112: Interval to send out reports of group 2

Time interval to send reports of group 2 Defines the time interval when the defined report of Reporting Group 2 is sent out.

0 s - 65535 s - Interval Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 720.

This parameter has the configuration ID config_112_4 and is of type INTEGER.

Parameter 113: Interval to send out reports of group 3

Time interval when report of Reporting Group 3 is sent. Defines the time interval when the defined report of Reporting Group 3 is sent out.

0 s - 65535 s - Interval Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 65535.

This parameter has the configuration ID config_113_4 and is of type INTEGER.

Parameter 252: Enable/disable Configuration Lock

The following option values may be configured -:

Value Description
0 Disable
1 Enable

The manufacturer defined default value is 0 (Disable).

This parameter has the configuration ID config_252_1 and is of type INTEGER.

Wakeup Interval

The wakeup interval sets the period at which the device will listen for messages from the controller. This is required for battery devices that sleep most of the time in order to conserve battery life. The device will wake up at this interval and send a message to the controller to tell it that it can accept messages - after a few seconds, it will go back to sleep if there is no further communications.

This setting is defined in seconds. It is advisable not to set this interval too short or it could impact battery life. A period of 1 hour (3600 seconds) is suitable in most instances.

Note that this setting does not affect the devices ability to send sensor data, or notification events.

This parameter has the configuration ID wakeup_interval and is of type INTEGER.

Wakeup Node

When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address. In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.

This parameter has the configuration ID wakeup_node and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The ZW075 supports 2 association groups.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.

Association group 1 supports 5 nodes.

Group 2: Group 2

Association group 2 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_APPLICATION_STATUS_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_SCENE_ACTIVATION_V1
COMMAND_CLASS_SENSOR_BINARY_V1
COMMAND_CLASS_METER_V3
COMMAND_CLASS_CRC_16_ENCAP_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_WAKE_UP_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1

Documentation Links