This describes the Z-Wave device ZW074, manufactured by AEON Labs with the thing type UID of aeon_zw074_00_000
.
The device is in the category of Sensor, defining Device used to measure something.
The ZW074 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The ZW074 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.
The Aeotec by Aeon Labs MultiSensor Gen5 looks like a motion sensor and it acts like one too. But it’s also so much more. Installing this 1 piece of Z-Wave technology is the same as installing 4 pieces of Z-Wave technology. Your home control network will immediately understand motion, temperature, humidity and light readings wherever Multisensor installed. Those intelligent readings will equate to intelligence automation. And intelligent automation will give you the perfect, smart home
Press the Z-Wave button under the Battery Cover to begin the Z-Wave pairing process.
If the MultiSensor was not successfully paired into any Z-Wave network the LED on the MultiSensor will blink when pressing the Z-Wave button. If the MultiSensor was successfully paired into a Z-Wave network, the LED will stay solid for a few seconds when pressing the Z-Wave button.
Press the Z-Wave button under the Battery Cover to begin the Z-Wave exclusion process.
If the MultiSensor was successfully removed from the Z-Wave network, pressing the Z-Wave button will cause the LED to blink. If the MultiSensor was not successfully removed from the Z-Wave network the LED will stay solid for a few seconds
The ZW074 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.
The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
Press and hold the Z-Wave button for 3 seconds will trigger sending the Wake up notification command. If press the Z-Wave button 3 times, the MultiSensor will wake up for 10 minutes.
The following table summarises the channels available for the ZW074 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Binary Sensor | sensor_binary | sensor_binary | Switch | |
Sensor (temperature) | sensor_temperature | sensor_temperature | Temperature | Number:Temperature |
Sensor (luminance) | sensor_luminance | sensor_luminance | Number | |
Sensor (relative humidity) | sensor_relhumidity | sensor_relhumidity | Humidity | Number |
Alarm | alarm_general | alarm_general | Alarm | Switch |
Battery Level | battery-level | system.battery_level | Battery | Number |
Indicates if a sensor has triggered.
The sensor_binary
channel is of type sensor_binary
and supports the Switch
item. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Triggered |
OFF | Untriggered |
Indicates the current temperature.
The sensor_temperature
channel is of type sensor_temperature
and supports the Number:Temperature
item and is in the Temperature
category.
Indicates the current light reading.
The sensor_luminance
channel is of type sensor_luminance
and supports the Number
item. This is a read only channel so will only be updated following state changes from the device.
Indicates the current relative humidity.
The sensor_relhumidity
channel is of type sensor_relhumidity
and supports the Number
item and is in the Humidity
category. This is a read only channel so will only be updated following state changes from the device.
Indicates if an alarm is triggered.
The alarm_general
channel is of type alarm_general
and supports the Switch
item and is in the Alarm
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The system.battery-level
channel is of type system.battery-level
and supports the Number
item and is in the Battery
category.
This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.
The following table provides a summary of the 18 configuration parameters available in the ZW074. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
2 | Wake up for 10 minutes when batteries are inserted | |
3 | On time | Time to keep state On before sending Off command |
4 | Motion sensor | |
5 | Command Class | Which command would be sent when the motion sensor triggered. |
40 | Enable/disable the selective reporting | Enable/disable the selective reporting |
41 | Temperature threshold to trigger a report. | Temperature threshold to trigger a report. |
42 | Humidity threshold to trigger a report. | Threshold for change in humidity to trigger a report. |
43 | luminance report threshold | luminance report threshold |
44 | Battery level to induce an automatic report. | Battery level to induce an automatic report. |
46 | Enable/disable low temperature alarm report | Enable/disable low temperature alarm report |
101 | Reports sent automatically for group 1 | Reports sent automatically for group 1 |
102 | Reports sent automatically for group 2 | Reports sent automatically for group 2 |
103 | Reports sent automatically for group 3 | Reports sent automatically for group 3 |
111 | Interval to send out reports of group 1 | |
112 | Interval to send out reports of group 2 | |
113 | Interval to send out reports of group 3 | |
252 | Enable/disable Configuration Locked | |
255 | Reset to default factory setting. | |
Wakeup Interval | Sets the interval at which the device will accept commands from the controller | |
Wakeup Node | Sets the node ID of the device to receive the wakeup notifications |
Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Time to keep state On before sending Off command How long should the device associated to multi sensor keep state On before sending it Off command (if the value is bigger than 255, the value would be rounded to next integer in minutes) Values in the range 1 to 15300 may be set.
The manufacturer defined default value is 240
.
This parameter has the configuration ID config_3_2
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Disabled |
1 | Enabled |
The manufacturer defined default value is 1
(Enabled).
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Which command would be sent when the motion sensor triggered.
The following option values may be configured -:
Value | Description |
---|---|
1 | Basic Set |
2 | Sensor Binary Report |
The manufacturer defined default value is 1
(Basic Set).
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Enable/disable the selective reporting Enable/disable the selective reporting only when measurements reach a certain threshold or percentage set in 41‐44 below.
This is used to reduce network traffic. The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_40_1
and is of type INTEGER
.
Temperature threshold to trigger a report.
- When the unit is Celsius, threshold=Value.
- When the unit is Fahrenheit, threshold=Value*1.8. The accuracy is 0.1.
- The high byte is the part of integer, the low byte is the fractional part. Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_41_2
and is of type INTEGER
.
Threshold for change in humidity to trigger a report. The accuracy is 0.1.
The high byte is the part of integer, the low byte is the fractional part. Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_42_2
and is of type INTEGER
.
luminance report threshold Threshold for changes in luminance to trigger a report. Note the sensor range is just 1-1000 lux ! Values in the range 0 to 1000 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_43_2
and is of type INTEGER
.
Battery level to induce an automatic report. The accuracy is 0.1.
The high byte is the part of integer, the low byte is the fractional part. Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_44_2
and is of type INTEGER
.
Enable/disable low temperature alarm report Enable/disable to send the alarm report of low temperature(‐15C) The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enabled |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_46_1
and is of type INTEGER
.
Reports sent automatically for group 1 The value is a combination number made up of the sum of the values for the individual sensors and battery. The sensors have the values:
- Temperature=32
- Humidity=64
- Lightlevel=128
- Battery=1 Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_101_4
and is of type INTEGER
.
Reports sent automatically for group 2 The value is a combination number made up of the sum of the values for the individual sensors and battery.
The sensors have the values:
- Temperature=32
- Humidity=64
- Lightlevel=128
- Battery=1 Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_102_4
and is of type INTEGER
.
Reports sent automatically for group 3 The value is a combination number made up of the sum of the values for the individual sensors and battery.
The sensors have the values:
- Temperature=32
- Humidity=64
- Lightlevel=128
- Battery=1 Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_103_4
and is of type INTEGER
.
Values in the range 1 to 2678400 may be set.
The manufacturer defined default value is 720
.
This parameter has the configuration ID config_111_4
and is of type INTEGER
.
Values in the range 1 to 2678400 may be set.
The manufacturer defined default value is 720
.
This parameter has the configuration ID config_112_4
and is of type INTEGER
.
Values in the range 1 to 2678400 may be set.
The manufacturer defined default value is 720
.
This parameter has the configuration ID config_113_4
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enabled |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_252_1
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
1 | Reset all configuration to default |
1431655765 | Reset to default exclude from the network |
The manufacturer defined default value is 1
(Reset all configuration to default).
This parameter has the configuration ID config_255_4_wo
and is of type INTEGER
.
This is a write only parameter.
The wakeup interval sets the period at which the device will listen for messages from the controller. This is required for battery devices that sleep most of the time in order to conserve battery life. The device will wake up at this interval and send a message to the controller to tell it that it can accept messages - after a few seconds, it will go back to sleep if there is no further communications.
This setting is defined in seconds. It is advisable not to set this interval too short or it could impact battery life. A period of 1 hour (3600 seconds) is suitable in most instances.
Note that this setting does not affect the devices ability to send sensor data, or notification events.
This parameter has the configuration ID wakeup_interval
and is of type INTEGER
.
When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address. In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.
This parameter has the configuration ID wakeup_node
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZW074 supports 5 association groups.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.
Association group 1 supports 5 nodes.
Association group 2 supports 5 nodes.
Association group 3 supports 5 nodes.
Association group 4 supports 5 nodes.
Association group 5 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SENSOR_MULTILEVEL_V5 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_WAKE_UP_V2 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |