This describes the Z-Wave device DSC13, manufactured by AEON Labs with the thing type UID of aeon_dsc13_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The DSC13 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
The Aeon Labs Micro SEI is a scene multilevel switch device based on Zwave enhanced slave library V4.54.
Click the button once.
Click the button once.
The following table summarises the channels available for the DSC13 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Dimmer | switch_dimmer | switch_dimmer | DimmableLight | Dimmer |
Sensor (power) | sensor_power | sensor_power | Energy | Number |
Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number |
Electric meter (watts) | meter_watts | meter_watts | Energy | Number |
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer
channel is of type switch_dimmer
and supports the Dimmer
item and is in the DimmableLight
category.
Indicates the energy consumption (kWh).
The sensor_power
channel is of type sensor_power
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
The following table provides a summary of the 12 configuration parameters available in the DSC13. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Type of Sensor Report | Defines the value type to be sent as Sensor Report. |
2 | Blinking Behavior | See overview |
80 | Notification on Status Change | Type of report to send when the device status changes |
90 | Disable Minimum Change report | |
91 | Minimum Change to send Report (Watt) | The minimum change in Wattage for a Report to be sent |
92 | Minimum Change to send Report (%) | The minimum change in Wattage Percent for a report to be sent |
101 | Reports to send to Group 1 | See overview |
102 | Reports to send to Group 2 | See overview |
103 | Reports to send to Group 3 | See overview |
111 | Interval to send out reports of group 1 | Time interval to send report to Group 1 |
112 | Interval to send out reports of group 2 | Time interval to send report to Group 2 |
113 | Interval to send out reports of group 3 | Time interval to send report to Group 3 |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Defines the value type to be sent as Sensor Report.
The following option values may be configured, in addition to values in the range 0 to 1 -:
Value | Description |
---|---|
0 | Power |
1 | Voltage |
The manufacturer defined default value is 0
(Power).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
See overview The LSB defines the total time the device need to blink. The value if set in seconds. The MSB defines the on/off interval of the blinking. The unit is 0.1 s. Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_2_2
and is of type INTEGER
.
Type of report to send when the device status changes
The following option values may be configured, in addition to values in the range 0 to 2 -:
Value | Description |
---|---|
0 | Nothing |
1 | Hail |
2 | Basic CC Report |
The manufacturer defined default value is 0
(Nothing).
This parameter has the configuration ID config_80_1
and is of type INTEGER
.
The following option values may be configured, in addition to values in the range 0 to 1 -:
Value | Description |
---|---|
0 | Disabled |
1 | Enabled |
The manufacturer defined default value is 0
(Disabled).
This parameter has the configuration ID config_90_1
and is of type INTEGER
.
The minimum change in Wattage for a Report to be sent
Values in the range 0 to 32000 may be set.
The manufacturer defined default value is 50
.
This parameter has the configuration ID config_91_2
and is of type INTEGER
.
The minimum change in Wattage Percent for a report to be sent
Values in the range 0 to 100 may be set.
The manufacturer defined default value is 10
.
This parameter has the configuration ID config_92_1
and is of type INTEGER
.
See overview The value is a combination number made up of the sum of the values for the individual parameters. The parameters have the values: Wattage=4, Current=2, Voltage=1. Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 4
.
This parameter has the configuration ID config_101_4
and is of type INTEGER
.
See overview The value is a combination number made up of the sum of the values for the individual parameters. The parameters have the values: Wattage=4, Current=2, Voltage=1. Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 4
.
This parameter has the configuration ID config_102_4
and is of type INTEGER
.
See overview The value is a combination number made up of the sum of the values for the individual parameters. The parameters have the values: Wattage=4, Current=2, Voltage=1. Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 4
.
This parameter has the configuration ID config_103_4
and is of type INTEGER
.
Time interval to send report to Group 1
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 720
.
This parameter has the configuration ID config_111_4
and is of type INTEGER
.
Time interval to send report to Group 2
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 720
.
This parameter has the configuration ID config_112_4
and is of type INTEGER
.
Time interval to send report to Group 3
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 720
.
This parameter has the configuration ID config_113_4
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The DSC13 supports 3 association groups.
Status Reports
Association group 1 supports 5 nodes.
Association group 2 supports 5 nodes.
Association group 3 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V3 | |
COMMAND_CLASS_METER_V2 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |