This describes the Z-Wave device DSC13, manufactured by AEON Labs with the thing type UID of aeon_dsc13_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

DSC13 product image

The DSC13 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

The Aeon Labs Micro SEI is a scene multilevel switch device based on Zwave enhanced slave library V4.54.

Inclusion Information

Click the button once.

Exclusion Information

Click the button once.

Channels

The following table summarises the channels available for the DSC13 -:

Channel Name Channel ID Channel Type Category Item Type
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer
Sensor (power) sensor_power sensor_power Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number

Dimmer

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel is of type switch_dimmer and supports the Dimmer item and is in the DimmableLight category.

Sensor (power)

Indicates the energy consumption (kWh).

The sensor_power channel is of type sensor_power and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Device Configuration

The following table provides a summary of the 12 configuration parameters available in the DSC13. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Type of Sensor Report Defines the value type to be sent as Sensor Report.
2 Blinking Behavior See overview
80 Notification on Status Change Type of report to send when the device status changes
90 Disable Minimum Change report
91 Minimum Change to send Report (Watt) The minimum change in Wattage for a Report to be sent
92 Minimum Change to send Report (%) The minimum change in Wattage Percent for a report to be sent
101 Reports to send to Group 1 See overview
102 Reports to send to Group 2 See overview
103 Reports to send to Group 3 See overview
111 Interval to send out reports of group 1 Time interval to send report to Group 1
112 Interval to send out reports of group 2 Time interval to send report to Group 2
113 Interval to send out reports of group 3 Time interval to send report to Group 3
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: Type of Sensor Report

Defines the value type to be sent as Sensor Report.

The following option values may be configured, in addition to values in the range 0 to 1 -:

Value Description
0 Power
1 Voltage

The manufacturer defined default value is 0 (Power).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Blinking Behavior

See overview The LSB defines the total time the device need to blink. The value if set in seconds. The MSB defines the on/off interval of the blinking. The unit is 0.1 s. Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_2_2 and is of type INTEGER.

Parameter 80: Notification on Status Change

Type of report to send when the device status changes

The following option values may be configured, in addition to values in the range 0 to 2 -:

Value Description
0 Nothing
1 Hail
2 Basic CC Report

The manufacturer defined default value is 0 (Nothing).

This parameter has the configuration ID config_80_1 and is of type INTEGER.

Parameter 90: Disable Minimum Change report

The following option values may be configured, in addition to values in the range 0 to 1 -:

Value Description
0 Disabled
1 Enabled

The manufacturer defined default value is 0 (Disabled).

This parameter has the configuration ID config_90_1 and is of type INTEGER.

Parameter 91: Minimum Change to send Report (Watt)

The minimum change in Wattage for a Report to be sent

Values in the range 0 to 32000 may be set.

The manufacturer defined default value is 50.

This parameter has the configuration ID config_91_2 and is of type INTEGER.

Parameter 92: Minimum Change to send Report (%)

The minimum change in Wattage Percent for a report to be sent

Values in the range 0 to 100 may be set.

The manufacturer defined default value is 10.

This parameter has the configuration ID config_92_1 and is of type INTEGER.

Parameter 101: Reports to send to Group 1

See overview The value is a combination number made up of the sum of the values for the individual parameters. The parameters have the values: Wattage=4, Current=2, Voltage=1. Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 4.

This parameter has the configuration ID config_101_4 and is of type INTEGER.

Parameter 102: Reports to send to Group 2

See overview The value is a combination number made up of the sum of the values for the individual parameters. The parameters have the values: Wattage=4, Current=2, Voltage=1. Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 4.

This parameter has the configuration ID config_102_4 and is of type INTEGER.

Parameter 103: Reports to send to Group 3

See overview The value is a combination number made up of the sum of the values for the individual parameters. The parameters have the values: Wattage=4, Current=2, Voltage=1. Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 4.

This parameter has the configuration ID config_103_4 and is of type INTEGER.

Parameter 111: Interval to send out reports of group 1

Time interval to send report to Group 1

Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 720.

This parameter has the configuration ID config_111_4 and is of type INTEGER.

Parameter 112: Interval to send out reports of group 2

Time interval to send report to Group 2

Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 720.

This parameter has the configuration ID config_112_4 and is of type INTEGER.

Parameter 113: Interval to send out reports of group 3

Time interval to send report to Group 3

Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 720.

This parameter has the configuration ID config_113_4 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The DSC13 supports 3 association groups.

Group 1: Group 1

Status Reports

Association group 1 supports 5 nodes.

Group 2: Group 2

Association group 2 supports 5 nodes.

Group 3: Group 3

Association group 3 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V3
COMMAND_CLASS_METER_V2
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1

Documentation Links