This describes the Z-Wave device DSB28, manufactured by AEON Labs with the thing type UID of aeon_dsb28_00_000
.
The device is in the category of Sensor, defining Device used to measure something.
The DSB28 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Aeon Labs Home Energy Meter is a kind of energy meter for the entire home electric power consumption. It can report immediate wattage and kWh and voltage and amperage usage of the AC mains to a Z-Wave gateway wirelessly.
It can send Z-Wave REPORTS (Meter v3 Command Class) to response Z-Wave GET command at any time.
HEM can also be configured as sending unsolicited reports periodically to the associated nodes (within an association group). The time interval of reports can also be configured HEM can also send report of each individual channel with corresponding current clamp via the command of “Multi Channel Command Class Encapsulation ”.
To reduce the network traffic, HEM can send reports only when the loads significant change occurred(by percentage or Wattage value change, which can be configured)
- Connect HEM G2 to power and install the device properly (according to the Installation instruction, if necessary, please ask an electrician for help) , at beginning its LED blink slowly.
- Let the primary controller of existing Z-Wave network into inclusion mode (If you don’t know how to do this, refer to its manual).
- Press the Z-Wave button of HEM G2.
- If learning success, HEM G2 LED will stop slow blink, or it will still slow blink, please repeat the process from step 2.
- Make sure the HEM G2 is powered, its LED be light on steadily.
- Let the primary controller of existing Z-Wave network into remove mode (If you don’t know how to do this, refer to its manual).
- Press the Z-Wave button.
- If exclusion success, HEM G2 LED will blink slowly or its LED still be on, please repeat the process from step 2.
Reset HEM G2 to factory Default:
- Make sure HEM G2 has been connected to the power supply.
- Press and hold the Z-wave button for 10 seconds.
- If HEM G2 LED blinks slowly, it indicates reset success, otherwise please repeat step 2.
Note:
Reset HEM G2 to factory default Settings will: sets the HEM G2 to not in Z-Wave network state; delete the Association setting, power measure value and restore the Configuration Settings to the default.
The following table summarises the channels available for the DSB28 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Electric meter (watts) | meter_watts | meter_watts | Energy | Number |
Electric meter (amps) | meter_current | meter_current | Energy | Number |
Electric meter (volts) | meter_voltage | meter_voltage | Energy | Number |
Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number |
Reset Meter | meter_reset | meter_reset | Energy | Switch |
Reporting Interval- Group 1 | config_decimal | config_decimal | Number | |
Electric meter (watts) 1 | meter_watts1 | meter_watts | Energy | Number |
Electric meter (amps) 1 | meter_current1 | meter_current | Energy | Number |
Electric meter (volts) 1 | meter_voltage1 | meter_voltage | Energy | Number |
Electric meter (kWh) 1 | meter_kwh1 | meter_kwh | Energy | Number |
Electric meter (watts) 2 | meter_watts2 | meter_watts | Energy | Number |
Electric meter (amps) 2 | meter_current2 | meter_current | Energy | Number |
Electric meter (volts) 2 | meter_voltage2 | meter_voltage | Energy | Number |
Electric meter (kWh) 2 | meter_kwh2 | meter_kwh | Energy | Number |
Electric meter (watts) 3 | meter_watts3 | meter_watts | Energy | Number |
Electric meter (volts) 3 | meter_voltage3 | meter_voltage | Energy | Number |
Electric meter (amps) 3 | meter_current3 | meter_current | Energy | Number |
Electric meter (kWh) 3 | meter_kwh3 | meter_kwh | Energy | Number |
Indicates the instantaneous power consumption.
The meter_watts
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous current consumption.
The meter_current
channel is of type meter_current
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous voltage.
The meter_voltage
channel is of type meter_voltage
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Reset the meter.
The meter_reset
channel is of type meter_reset
and supports the Switch
item and is in the Energy
category.
Change the reporting interval to reduce network traffic during off hours
Generic class for configuration parameter.
The config_decimal
channel is of type config_decimal
and supports the Number
item.
Indicates the instantaneous power consumption.
The meter_watts1
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous current consumption.
The meter_current1
channel is of type meter_current
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous voltage.
The meter_voltage1
channel is of type meter_voltage
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh1
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts2
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous current consumption.
The meter_current2
channel is of type meter_current
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous voltage.
The meter_voltage2
channel is of type meter_voltage
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh2
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts3
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous voltage.
The meter_voltage3
channel is of type meter_voltage
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous current consumption.
The meter_current3
channel is of type meter_current
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh3
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
The following table provides a summary of the 17 configuration parameters available in the DSB28. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
2 | Reverse clamping | If the reverse clamping pliers, negative power is detected. |
3 | Selective Reporting | Report only when power change reaches a threshold set in 4-11 below. |
4 | Power Threshold - Whole HEM | Threshold change in power to induce an automatic report (Whole HEM). |
5 | Power Threshold - Clamp 1 | Threshold change in power to induce an automatic report (Clamp 1) |
6 | Power Threshold - Clamp 2 | Threshold change in power to induce a automatic report (Clamp 2). |
7 | Power Threshold - Clamp 3 | Threshold change in power to induce an automatic report (Clamp 3). |
8 | Percent Change - Whole HEM | Percentage change in power to induce an automatic report (Whole HEM). |
9 | Percent Change - Clamp 1 | Percentage change in power to induce an automatic report (Clamp 1). |
10 | Percent Change - Clamp 2 | Percentage change in power to induce a automatic report (Clamp 2). |
11 | Percent Change - Clamp 3 | Percentage change in power to induce a automatic report (Clamp 3). |
101 | Reports for group 1 | Reports for group 1 |
102 | Reports for group 2 | Reports for group 2 |
103 | Reports for group 3 | Reports for group 3 |
111 | Interval to send out reports of group 1 | |
112 | Interval to send out reports of group 2 | |
113 | Interval to send out reports of group 3 | |
255 | Factory Reset | Reset all settings to factory defaults |
If the reverse clamping pliers, negative power is detected.
The following option values may be configured -:
Value | Description |
---|---|
0 | Disabled |
1 | Enabled |
The manufacturer defined default value is 0
(Disabled).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Report only when power change reaches a threshold set in 4-11 below. Enable selective reporting only when power change reaches a certain threshold or percentage set in 4-11 below.
This is used to reduce network traffic.(Bit 0: Whole HEM ,Bit 1:Clamp 1,Bit 2:Clamp 2,Bit 3:Clamp 3) Values in the range 0 to 16 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Threshold change in power to induce an automatic report (Whole HEM). Threshold change in wattage to induce a automatic report (Whole HEM). (Valid values 0-60000) Values in the range 0 to 60000 may be set.
The manufacturer defined default value is 50
.
This parameter has the configuration ID config_4_2
and is of type INTEGER
.
Threshold change in power to induce an automatic report (Clamp 1) Threshold change in wattage to induce a automatic report (Clamp 1). (Valid values 0-60000) Values in the range 0 to 60000 may be set.
The manufacturer defined default value is 50
.
This parameter has the configuration ID config_5_2
and is of type INTEGER
.
Threshold change in power to induce a automatic report (Clamp 2). Threshold change in wattage to induce a automatic report (Clamp 2). (Valid values 0-60000) Values in the range 0 to 60000 may be set.
The manufacturer defined default value is 50
.
This parameter has the configuration ID config_6_2
and is of type INTEGER
.
Threshold change in power to induce an automatic report (Clamp 3). Threshold change in wattage to induce a automatic report (Clamp 3). (Valid values 0-60000) Values in the range 0 to 60000 may be set.
The manufacturer defined default value is 50
.
This parameter has the configuration ID config_7_2
and is of type INTEGER
.
Percentage change in power to induce an automatic report (Whole HEM). Percentage change in wattage to induce a automatic report (Whole HEM). (Valid values 0-100) Values in the range 0 to 100 may be set.
The manufacturer defined default value is 50
.
This parameter has the configuration ID config_8_1
and is of type INTEGER
.
Percentage change in power to induce an automatic report (Clamp 1). Percentage change in wattage to induce a automatic report (Clamp 1). (Valid values 0-100) Values in the range 0 to 100 may be set.
The manufacturer defined default value is 50
.
This parameter has the configuration ID config_9_1
and is of type INTEGER
.
Percentage change in power to induce a automatic report (Clamp 2). Percentage change in wattage to induce a automatic report (Clamp 2). (Valid values 0-100) Values in the range 0 to 100 may be set.
The manufacturer defined default value is 50
.
This parameter has the configuration ID config_10_1
and is of type INTEGER
.
Percentage change in power to induce a automatic report (Clamp 3). Percentage change in wattage to induce a automatic report (Clamp 3). (Valid values 0-100) Values in the range 0 to 100 may be set.
The manufacturer defined default value is 50
.
This parameter has the configuration ID config_11_1
and is of type INTEGER
.
Reports for group 1 1 -> Battery Report
2 -> MultiSensor Report for the whole device
4 -> Meter Report for Watt for the whole device
8 -> Meter Report for kWh for the whole device
256 -> Meter Report for Watt for clamp 1
512 -> Meter Report for W Values in the range 0 to 1061109568 may be set.
The manufacturer defined default value is 8
.
This parameter has the configuration ID config_101_4
and is of type INTEGER
.
Reports for group 2 1 -> Battery Report
2 -> MultiSensor Report for the whole device
4 -> Meter Report for Watt for the whole device
8 -> Meter Report for kWh for the whole device
256 -> Meter Report for Watt for clamp 1
512 -> Meter Report for W Values in the range 0 to 1061109568 may be set.
The manufacturer defined default value is 8
.
This parameter has the configuration ID config_102_4
and is of type INTEGER
.
Reports for group 3 1 -> Battery Report
2 -> MultiSensor Report for the whole device
4 -> Meter Report for Watt for the whole device
8 -> Meter Report for kWh for the whole device
256 -> Meter Report for Watt for clamp 1
512 -> Meter Report for W Values in the range 0 to 1061109568 may be set.
The manufacturer defined default value is 8
.
This parameter has the configuration ID config_103_4
and is of type INTEGER
.
Values in the range 1 to 2678400 may be set.
The manufacturer defined default value is 720
.
This parameter has the configuration ID config_111_4
and is of type INTEGER
.
Values in the range 1 to 2678400 may be set.
The manufacturer defined default value is 720
.
This parameter has the configuration ID config_112_4
and is of type INTEGER
.
Values in the range 1 to 2678400 may be set.
The manufacturer defined default value is 720
.
This parameter has the configuration ID config_113_4
and is of type INTEGER
.
Reset all settings to factory defaults If you upgrade firmware and are seeing crazy or impossible numbers, reset to factory then reconfigure unit.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -:
Value | Description |
---|---|
0 | Do nothing |
1 | Reset to Factory Defaults |
The manufacturer defined default value is 0
(Do nothing).
This parameter has the configuration ID config_255_1
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The DSB28 supports 3 association groups.
Association group 1 supports 5 nodes.
Association group 2 supports 5 nodes.
Association group 3 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_METER_V3 | Linked to BASIC |
COMMAND_CLASS_CRC_16_ENCAP_V1 | |
COMMAND_CLASS_MULTI_CHANNEL_V2 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_METER_V3 | Linked to BASIC |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_METER_V3 | Linked to BASIC |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_METER_V3 | Linked to BASIC |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.