This describes the Z-Wave device ZRM230, manufactured by ACT - Advanced Control Technologies with the thing type UID of act_zrm230_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The ZRM230 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Radio Frequency Controlled, 6A, 230 VAC, European Wall Mounted 3-Way Switch, Dual Switch, Release 1.1
The ZRM230 Wall Mounted 3-Way Switch is a component of the HomePro lighting control system. This Wall Mounted Switch is designed to work with other Z-Wave enabled devices. Z-Wave nodes of other types can be added to the system and will also act as repeaters if they support this function of repeating the signal received to other modules in the system.
Including to the Network (Must be installed in permanent location, not on test bench).
- Setup the controller you are using to include a device into network.
- Tap either the top or bottom of the left switch once
- Setup the controller you are using to exclude a device from the network.
- Tap either the top or the bottom of the left switch once.
The following table summarises the channels available for the ZRM230 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
The following table provides a summary of the 9 configuration parameters available in the ZRM230. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Ignore start level | Set ignore start level bit when transmitting dim commands. |
2 | Suspend Group 4 | Disable transmitting commands to group 4 devices. |
3 | Night Light | LED behaviour of the ZRM230. |
4 | Invert Switch | Switch (paddle) behaviour. |
14 | Enable Shade Control Group 2 | Operate shade control devices on group 2. |
15 | Enable Shade Control Group 3 | Operate shade control devices on group 3. |
19 | LED Transmission Indication | Z-Wave transmission LED settings. |
20 | Poll Group 2 Interval | Poll Group 2 interval (minutes). |
22 | Poll Group 2 | Group 2 poll control. |
Set ignore start level bit when transmitting dim commands. The ZRM230 can send Dim commands to Z-Wave enabled dimmers. The Dim command has a start level embedded in it. A dimmer receiving this command will start dimming from that start level. However, the command also has a bit that indicates whether the dimmer should ignore the start level. If the bit is set to 1, the dimmer will ignore the start level and instead start dimming from its current level. If this bit is set to 0, the dimmer will ignore the start level. The following option values may be configured -:
Value | Description |
---|---|
0 | Ignore start level |
1 | Do not ignore start level |
The manufacturer defined default value is 1
(Do not ignore start level).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Disable transmitting commands to group 4 devices. You may wish to disable transmitting commands to Z-Wave devices that are in Group 4 without “disassociating” those devices from the group. Setting parameter 2 to the value of 1 will stop the ZRM230 from transmitting todevices that are “associated” into Group 4. The following option values may be configured -:
Value | Description |
---|---|
0 | Transmit to group 4 devices |
1 | Stop transmit to group 4 devices |
The manufacturer defined default value is 0
(Transmit to group 4 devices).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
LED behaviour of the ZRM230. The LED on the ZRM230 will by default, turn ON when the load attached is turned ON. To make the LED turn ON when the load attached is turned OFF instead, set parameter 3 to a value of 1. The following option values may be configured -:
Value | Description |
---|---|
0 | Led when load on |
1 | Led when load off |
The manufacturer defined default value is 0
(Led when load on).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Switch (paddle) behaviour. To change the top of the switch to OFF and the bottom of the switch ON , set parameter 4 to 1. Note: If you invert the switches and also install the product upside down, remember the load will now be controlled by the right, not the left switch. The following option values may be configured -:
Value | Description |
---|---|
0 | Invert off |
1 | Invert on |
The manufacturer defined default value is 0
(Invert off).
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Operate shade control devices on group 2. The ZRM230 can operate shade control devices via its group 2 if this configuration parameter is set to 1. Values in the range 0 to 1 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_14_1
and is of type INTEGER
.
Operate shade control devices on group 3. The ZRM230 can operate shade control devices via its group 3 if this configuration parameter is set to 1. Values in the range 0 to 1 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_15_1
and is of type INTEGER
.
Z-Wave transmission LED settings. The ZRM230 will flicker its LED when it is transmitting to any of its 4 groups. This flickering can be set to notflicker at all (set to 0), to flicker the entire time it is transmitting (set to 1), or to flicker for only 1 second when it begins transmitting (set to 2). By default, the ZRM230 is set to flicker for only 1 second. The following option values may be configured -:
Value | Description |
---|---|
0 | No flicker |
1 | Flicker for 1 second (default) |
2 | Flicker for 2 second |
The manufacturer defined default value is 2
(Flicker for 2 second).
This parameter has the configuration ID config_19_1
and is of type INTEGER
.
Poll Group 2 interval (minutes). Poll Group 2 Interval (minutes), valid values = 1 through 255 (Default value is 2). Values in the range 0 to 255 may be set.
The manufacturer defined default value is 2
.
This parameter has the configuration ID config_20_1
and is of type INTEGER
.
Group 2 poll control. Poll Group 2, if value is 1, the ZRM230 will poll group 2 at the interval set in configuration Parameter 20. Values in the range 0 to 1 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_22_1
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZRM230 supports 4 association groups.
Association group 1 supports 5 nodes.
Association group 2 supports 5 nodes.
Association group 3 supports 5 nodes.
Group used to inform devices about the updates of the status of the device.
Association group 4 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_MULTILEVEL_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |