SHSG10000 High-volume siren (95 dB) and LED strobe light

This describes the Z-Wave device SHSG10000, manufactured by *ABUS Security-Center GmbH & Co. KG * with the thing type UID of abus_shsg10000_00_000.

The device is in the category of Siren, defining Siren used by Alarm systems.

SHSG10000 product image

The SHSG10000 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

This is a **secure Siren **for CEPT (Europe)

Once the device is added to a Z-Wave gateway, the alarm can be released and terminated. In Event of an Alarm the high-volume siren (95dB) will sound and LED strobe lights up.

Inclusion Information

  1. Plug the SHSG10000 into a socket
  2. Set the Gateway/Controller into inclusion mode
  3. Press the Network-button 3 times within 1.5 seconds and the Status-LED will flash 3 times
  4. If the Add device process is successful, the Status-LED will turn off.
  5. Repeat the inclusion process from step 2 if it was not successful.

Exclusion Information

  1. Plug the SHSG10000 into a socket
  2. Set the Gateway/Controller into exclusion mode
  3. Press the Network-button 3 times within 1.5 seconds and the Status-LED will flash 3 times
  4. If the Remove device process is successful, the Status-LED flash 6 times.
  5. Repeat the exlusion process from step 2 if it was not successful.

General Usage Information

In Event of main power loss, the Siren can even operate up to 5 minutes in Alarm case by the integrated backup-battery (or 4 hours standby operation).

Please make sure the internal battery is fully charged.

To reset the device:

  1. Press the Network-button for 10 seconds to factory reset the device

Note:

  • This procedure should only be used if the primary gateway is not capable of acting.
  • If the multi-sensor is set to the factory setting, the status is set to "not included", the association settings and possible configurations are reset to default.

Channels

The following table summarises the channels available for the SHSG10000 -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch
Battery Level battery-level system.battery_level Battery Number

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The system.battery-level channel is of type system.battery-level and supports the Number item and is in the Battery category. This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.

Device Configuration

The device has no configuration parameters defined.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The SHSG10000 supports 1 association group.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Lifeline association group includes command classes: Switch Binary report, Battery and Device Reset Locally notification.

Association group 1 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
COMMAND_CLASS_SECURITY_V1

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.