Only Bitaxe with the TPS546 voltage regulator support measuring this temp. On other machines the AxeOS measurement should be hidden.

Hardware that has the TPS546:

  • Ultra 207 and higher
  • Supra 402 and higher
  • Hex 302 and higher
image
@skot skot added the bug Something isn't working label Jun 20, 2024
@benjamin-wilson
Copy link
Collaborator

Rather than look at the specific board versions we can just check if the value is greater than the initialized value of 0. A temperature under 0 seems unlikely even in sub 0 temperatures.