Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathexhaustive_gs.physeng
110 lines (107 loc) · 5.23 KB
/
exhaustive_gs.physeng
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
<?xml version="1.0" encoding="UTF-8"?>
<!--
Available path/command replacements:
@INTERP@ : Interpreter command/path (cannot be used in the interpreter field).
@PYTHON@ : Use a Python interpreter command/path provided by SiQAD (either from the default settings or the user's overriden choice).
@BINPATH@ : Path to the binary or script path to the engine (cannot be used in the bin_path field).
@PHYSENGPATH@ : Path to the directory containing this *.physeng file.
@PROBLEMPATH@ : Path to the problem file describing the simulation problem and parameters.
@RESULTPATH@ : Path to the result file that will be read by SiQAD after the simulation is complete.
@JOBTMP@ : Temporary path for this simulation job to store generated files.
These replacements are done on the following fields:
interpreter, bin_path, command
-->
<physeng>
<name>ExhaustiveGS</name>
<version>0.2.2</version>
<description>Exhaustively search for the ground state electron configuration.</description>
<!-- Services this plugin provides, used by SimManager and DesignAssistant classes to identify the type of simulation or assistance this plugin can provide. Comma separated, spaces are neither ignored nor truncated. -->
<services>ElectronGroundState</services>
<!-- Path to the engine script or compiled binary. -->
<!--<bin_path>@PHYSENGPATH@/simanneal</bin_path> TODO switch to this form later-->
<bin_path>exhaustive_gs</bin_path> <!-- path to binary or script, relative to the folder containing engine_description.xml -->
<!-- Selection of invocation commands to call this engine. The first one is the one that is shown in SiQAD by default. TODO tie this to presets in some ways. -->
<commands>
<!-- Default command. -->
<command label="Ground State Only">
<program>@BINPATH@</program>
<arg>@PROBLEMPATH@</arg>
<arg>@RESULTPATH@</arg>
</command>
<!-- Import potentials from PoisSolver. -->
<command label="Import PoisSolver Potentials">
<program>@BINPATH@</program>
<arg>@PROBLEMPATH@</arg>
<arg>@RESULTPATH@</arg>
<arg>--ext-pots-file</arg>
<arg>@JOBTMP@/db_pots.json</arg>
</command>
<!-- Import potentials from PoisSolver. -->
<command label="QUBO Mapping (no metastability check)">
<program>@BINPATH@</program>
<arg>@PROBLEMPATH@</arg>
<arg>@RESULTPATH@</arg>
<arg>--qubo</arg>
</command>
</commands>
<!-- Python dependencies file path, relative to the directory containing this physeng file. -->
<dep_path></dep_path>
<!-- Simulation parameters, read into SiQAD as a property map. -->
<sim_params preserve_order="true">
<num_threads>
<T>int</T>
<val>-1</val>
<label>Thread count</label>
<tip>The number of concurrent threads to use. If left at -1, all available CPU cores are used.</tip>
</num_threads>
<muzm>
<T>float</T>
<val>-0.25</val>
<dp>2</dp>
<label>mu (0/- transition level - Fermi level)</label>
<tip>The global Fermi level on the surface, higher value brings more electrons to the surface.</tip>
</muzm>
<eps_r>
<T>float</T>
<val>5.6</val>
<dp>2</dp>
<label>Relative permittivity</label>
<tip>Surface relative permittivity. Original default was 6.35, changed to 5.6 after Huff's fitting in the paper Binary Atomic Silicon Logic on Nature Electronics.</tip>
</eps_r>
<debye>
<T>float</T>
<val>5</val>
<label>Debye length (nm)</label>
<tip>Debye length for screening.</tip>
</debye>
<base>
<T>int</T>
<val>3</val>
<label>State count</label>
<tip>Specify 2- or 3-state simulation.</tip>
</base>
<!--<auto_fail_threshold>
<T>int</T>
<val>15</val>
<label>Auto-fail DB count (read hover tip)</label>
<tip>Refuse to run problems with DB count greater than the specified size as a sanity check against running simulations that would take forever. Increase this number at your will, but keep in mind that the 3-state search problem space is 3^N where N is the DB count.</tip>
</auto_fail_threshold>-->
<scope>
<T>string</T>
<val>ground</val>
<label>Result scope</label>
<tip>Types of results to include.</tip>
<value_selection type="ComboBox">
<ground>Ground states only</ground>
<valid>All metastable</valid>
<all>All results</all>
</value_selection>
</scope>
<autofail>
<T>int</T>
<val>16</val>
<label>Autofail problem size</label>
<tip>Problems with greater than this number of DBs will fail automatically to prevent accidental invocation of prohibitively long simulation. Increase at your own risk.</tip>
</autofail>
</sim_params>