Information about Values

SmVforce edited this page Nov 16, 2024 · 33 revisions

Edit this page to enter your comments on the values.

Occurences Registry Name Comments
19 0x00,0,152,1 Sensor Data Qty Nombre de sondes
1 0x00,0,405,0 *Refrigerant type Type de fluide
12 0x00,0,801,0 *Refrigerant type
6 0x00,0,802,0 *Refrigerant type
4 0x00,0,995,1
34 0x00,0,995,1 NextDataGrid
9 0x00,0,996,0 Override All Clear
2 0x00,0,998,1
17 0x00,0,998,1 In-Out separator
19 0x00,1,152,1 INV compressor Qty How many Invertor Compressors are connected.
18 0x00,10,152,1 O/U MPU ID (xx)
1 0x00,10,213,1 O/U MPU ID
18 0x00,11,152,1 O/U MPU ID (yy)
1 0x00,11,213,1 O/U MPU ID
18 0x00,12,105,1 O/U capacity (kW)
1 0x00,2,152,1 STD Compressor
18 0x00,2,152,1 STD compressor Qty How many Standard Compressors are connected.
19 0x00,3,152,1 Fan Data Qty
19 0x00,4,152,1 Expansion Valve Data Qty
19 0x00,5,152,1 4 Way Valve Data Qty
19 0x00,6,152,1 Crank Case Heater Qty
19 0x00,7,152,1 Solenoid valve Qty
19 0x00,8,152,1 Max. connectable indoor units
19 0x00,9,152,1 Connected Indoor Unit Qty
19 0x10,0,217,1 Operation Mode tells you whether the compressor is doing nothing ('Fan only') or Heating
19 0x10,1,300,1 Low noise control Tells you whether the compressor is in low noise.
19 0x10,1,301,1 Demand Signal
19 0x10,1,302,1 Pressure equalizing operation
19 0x10,1,303,1 Oil Return Operation
19 0x10,1,304,1 Defrost Operation Tells you whether the defrost operation is active or not.
19 0x10,1,305,1 Startup Control
19 0x10,1,306,1 Restart standby
19 0x10,1,307,1 Thermostat ON/OFF
19 0x10,10,303,1 Comp. INV Current Drop
19 0x10,10,307,1 Discharge Temp. Drop
19 0x10,10,310,1 Discharge Temp. Protection Retry Qty
19 0x10,10,311,1 Comp. INV Current Protection Retry Qty
19 0x10,11,303,1 LP Drop Control
19 0x10,11,307,1 HP Drop Control
19 0x10,11,310,1 HP Protection Retry Qty
19 0x10,11,311,1 LP Protection Retry Qty
1 0x10,12,303,1 Other Control
18 0x10,12,303,1 Other Drop Control
18 0x10,12,307,1 Fin Temp. Drop Control
18 0x10,12,310,1 Fin Temp. Protection Retry Qty
18 0x10,12,311,1 Not in use
1 0x10,2,300,1 Other control 8
1 0x10,2,301,1 Other control 7
1 0x10,2,302,1 Other control 6
1 0x10,2,303,1 Other control 5
1 0x10,2,304,1 Other control 4
1 0x10,2,305,1 Other control 3
1 0x10,2,306,1 Other control 2
1 0x10,2,307,1 Other control 1
1 0x10,3,300,1 Other control 16
1 0x10,3,301,1 Other control 15
1 0x10,3,302,1 Other control 14
1 0x10,3,303,1 Other control 13
1 0x10,3,304,1 Other control 12
1 0x10,3,305,1 Other control 11
1 0x10,3,306,1 Other control 10
1 0x10,3,307,1 Other control 9
19 0x10,4,203,1 Error type Shows "Normal" in normal operation, but "Error" when there's a problem.
19 0x10,5,204,1 Error Code Shows "0" in normal operation. Example error code "7H" for water flow issues.
1 0x10,6,114,2, Target Discharge Temp.
18 0x10,6,114,2, Target Evap. Temp.
19 0x10,8,114,2, Target Cond. Temp.
18 0x11,0,215,1 O/U EEPROM (1st digit)
18 0x11,1,215,1 O/U EEPROM (3rd 4th digit)
18 0x11,2,215,1 O/U EEPROM (5th 6th digit)
18 0x11,3,215,1 O/U EEPROM (7th 8th digit)
18 0x11,4,215,1 O/U EEPROM (10th digit)
18 0x11,5,214,1 O/U EEPROM (11th digit)
3 0x20,0,105,2, Outdoor air temp.
16 0x20,0,105,2, Outdoor air temp.(R1T)
2 0x20,10,105,2, Leaving brine temp.(R6T)
4 0x20,10,105,2, Liquid pipe temp.
12 0x20,10,105,2, Liquid pipe temp.(R6T)
1 0x20,10,105,2, Liquid temperature(R3T) Current temp in underfloor
1 0x20,12,105,2, Fin Temp.
10 0x20,12,105,2, Heat sink temp.
1 0x20,12,105,2, Heat sink temp.(R10T)
3 0x20,12,105,2, INV fin temp.
4 0x20,12,105,2, High Pressure
3 0x20,12,405,2, High Pressure(T)
6 0x20,14,105,2, Low Pressure
3 0x20,14,105,2, Pressure sensor
10 0x20,14,105,2, Pressure
5 0x20,14,405,2, Low Pressure(T)
3 0x20,14,405,2, Pressure sensor(T)
10 0x20,14,405,2, Pressure(T)
5 0x20,16,105,2 Not in use
1 0x20,16,105,2 Sensor data 9
5 0x20,18,105,2 Not in use
1 0x20,18,105,2 Sensor data 10
2 0x20,2,105,2, 2 phase thermistor (R4T)
15 0x20,2,105,2, O/U Heat Exch. Temp.
2 0x20,2,105,2, Outdoor heat exchanger temp.
1 0x20,20,105,2 Sensor data 11
19 0x20,4,105,2, Discharge pipe temp.
1 0x20,6,105,2, Suction Pipe Temperature
16 0x20,6,105,2, Suction pipe temp.
2 0x20,6,105,2, Suction pipe temp.(R3T)
2 0x20,8,105,2, Entering brine temp.(R5T)
13 0x20,8,105,2, Heat exchanger mid-temp.
2 0x20,8,105,2, O/U Heat Exch. Mid-temp.
2 0x20,8,105,2, Outdoor heat exchanger mid temp.
19 0x21,0,105,2 INV primary current (A)
1 0x21,2,105,2 INV secondary current (A) Primary current is what goes into the inverter (230V/50Hz). Output current is the pulsed three phase current to the motor (variable voltage and frequency)
1 0x21,10,105,2 Sensor data 6
3 0x21,10,105,2, Compressor outlet temperature
1 0x21,10,105,2, Refrig. temp. evap.Out
1 0x21,10,152,2, Compressor outlet temperature
13 0x21,11,105,2, Refrig. temp. evap. In
1 0x21,12,105,2 Sensor data 7
1 0x21,12,105,2, Refrig. temp. evap.Out
13 0x21,13,105,2, Refrig. temp. evap.Out
1 0x21,14,105,2 Sensor data 8
14 0x21,15,105,1 Not in use
14 0x21,16,105,1 Not in use
1 0x21,16,105,2 Sensor data 9
14 0x21,17,105,1 Not in use
14 0x21,18,105,1 Not in use
1 0x21,18,105,2 Sensor data 10
1 0x21,2,101,2 Voltage (N-phase) (V) the voltage after the "transformer" for the compressor.
18 0x21,2,105,2 INV secondary current (A) the current after the "transformer" for each phase (there are always 3!)
1 0x21,20,105,2 Sensor data 11
11 0x21,4,101,2 Voltage (N-phase) (V) the voltage after the "transformer" for the compressor.
2 0x21,4,101,2 Voltage (V)
1 0x21,4,105,2, Brine inlet temp.
5 0x21,4,105,2, INV fin temp.
1 0x21,6,105,2 Sensor data 4
1 0x21,6,105,2, Brine inlet temp.
1 0x21,6,105,2, Brine outlet temp.
2 0x21,6,105,2, Fan1 Fin temp.
1 0x21,6,152,2, Fan1 Fin temp.
13 0x21,6,300,1 Not in use
13 0x21,6,301,1 Not in use
13 0x21,6,302,1 Not in use
13 0x21,6,303,1 Not in use
13 0x21,6,304,1 Not in use
13 0x21,6,305,1 Not in use
13 0x21,6,306,1 Not in use
13 0x21,6,307,1 Brine Flow Switch
13 0x21,7,105,2, Brine inlet temp.
1 0x21,8,105,2 Sensor data 5
1 0x21,8,105,2, Brine outlet temp.
2 0x21,8,105,2, Fan2 Fin temp.
1 0x21,8,105,2, Refrig. temp. evap. In
1 0x21,8,152,2, Fan2 Fin temp.
13 0x21,9,105,2, Brine outlet temp.
8 0x30,0,151,2 Expansion valve (pls)
3 0x30,0,151,2 Expansion valve 1 (pls)
18 0x30,0,152,1 INV frequency (rps)
1 0x30,0,152,1 INV frequency 1 (rps)
3 0x30,0,211,1 Fan 1 (10 rpm) (10 rpm) means that you should multiply by 10 to get rpm value. eg 5 -> 50rpm
8 0x30,0,211,1 Fan 1 (step)
1 0x30,0,300,1 Solenoid Valve 8
1 0x30,0,301,1 Solenoid Valve 7
1 0x30,0,302,1 Solenoid Valve 6
10 0x30,0,303,1 4 Way Valve 5
1 0x30,0,303,1 Crank case heater 5
12 0x30,0,303,1 Solenoid Valve 5
10 0x30,0,304,1 4 Way Valve 4
10 0x30,0,304,1 Crank case heater 4
12 0x30,0,304,1 Solenoid Valve 4
10 0x30,0,305,1 4 Way Valve 3
10 0x30,0,305,1 Crank case heater 3
11 0x30,0,305,1 Solenoid Valve 3
11 0x30,0,306,1 4 Way Valve 2
11 0x30,0,306,1 Crank case heater 2
11 0x30,0,306,1 STD Compressor 2
2 0x30,0,306,1 SV (BPH)
1 0x30,0,306,1 SV2 (BPH)
8 0x30,0,306,1 Solenoid Valve 2
9 0x30,0,307,1 4 Way Valve 1
2 0x30,0,307,1 4 Way Valve
9 0x30,0,307,1 Crank case heater 1
2 0x30,0,307,1 Crank case heater
11 0x30,0,307,1 STD Compressor 1
1 0x30,0,307,1 SV (hot Gas)
1 0x30,0,307,1 SV1 (hot gas)
9 0x30,0,307,1 Solenoid Valve 1
11 0x30,1,152,1 INV frequency 2 (rps)
1 0x30,1,211,1 Brine pump feedback
3 0x30,1,211,1 Fan 1 (10 rpm)
4 0x30,1,211,1 Fan 1 (step)
11 0x30,1,211,1 Fan 2 (step)
1 0x30,1,306,1 Solenoid Valve 10
1 0x30,1,307,1 Solenoid Valve 9
1 0x30,10,105,1, Inlet water temp. (DMW)
1 0x30,10,113,1, Inlet water temp. (DMW)
1 0x30,11,105,1, Outlet water hex temp. before BUH (DLWB2)
1 0x30,11,113,1, Outlet water hex temp. before BUH (DLWB2)
3 0x30,11,307,1 4 Way Valve
3 0x30,12,307,1 Crank case heater
3 0x30,13,305,1 Y3S
1 0x30,13,306,1 LP bypass valve (Y2S)
1 0x30,13,306,1 SV (drain pan heater)
1 0x30,13,306,1 Y2S
1 0x30,13,307,1 4 way valve (Y1S)
1 0x30,13,307,1 Hot gas bypass valve (Y3S)
1 0x30,13,307,1 Y1S
2 0x30,2,151,2 Expansion valve (pls)
11 0x30,2,151,2 Expansion valve 2 (pls)
5 0x30,2,211,1 Fan 2 (step)
1 0x30,2,211,1 Not in use
6 0x30,3,151,2 Expansion valve 1 (pls)
10 0x30,4,151,2 Expansion valve 3 (pls)
2 0x30,4,303,1 4 Way Valve 5
2 0x30,4,304,1 4 Way Valve 4
2 0x30,4,305,1 4 Way Valve 3
2 0x30,4,306,1 4 Way Valve 2
2 0x30,4,307,1 4 Way Valve 1
6 0x30,5,151,2 Expansion valve 2 (pls)
10 0x30,6,151,2 Expansion valve 4 (pls)
3 0x30,7,151,2 Expansion valve 3 (pls)
1 0x30,7,300,1 4 Way Valve 8
1 0x30,7,301,1 4 Way Valve 7
1 0x30,7,302,1 4 Way Valve 6
3 0x30,7,303,1 4 Way Valve 5
3 0x30,7,304,1 4 Way Valve 4
3 0x30,7,305,1 4 Way Valve 3
3 0x30,7,306,1 4 Way Valve 2
3 0x30,7,307,1 4 Way Valve 1
10 0x30,8,151,2 Expansion valve 5 (pls)
1 0x30,8,303,1 Crank case heater 5
2 0x30,8,304,1 Crank case heater 4
2 0x30,8,305,1 Crank case heater 3
2 0x30,8,306,1 Crank case heater 2
2 0x30,8,307,1 Crank case heater 1
1 0x30,8,307,1 Crank case heater
3 0x30,9,151,2 Expansion valve 4 (pls)
2 0x30,9,303,1 Solenoid Valve 5
2 0x30,9,304,1 Solenoid Valve 4
2 0x30,9,305,1 Solenoid Valve 3
1 0x30,9,305,1, Solenoid Valve 3
1 0x30,9,306,1 SV2 (BPH)
1 0x30,9,306,1 Solenoid Valve 2
1 0x30,9,306,1, LP bypass valve (Y3S)
1 0x30,9,307,1 SV1 (hot gas)
1 0x30,9,307,1 Solenoid Valve 1
1 0x30,9,307,1, Hot gas bypass valve (Y2S)
18 0x60,0,304,1 Data Enable/Disable
1 0x60,0,307,1 Data Enable/Disable
19 0x60,1,152,1 Indoor Unit Address
19 0x60,11,300,1 Bivalent Operation
19 0x60,11,301,1 Not in use Status of Smart Grid Contact 1
19 0x60,11,302,1 Not in use Status of Smart Grid Contact 2
19 0x60,11,303,1 Solar input
18 0x60,11,304,1 Benefit kWh rate power supply
1 0x60,11,304,1 HP tariff input
1 0x60,11,305,1 Clixon BSH
18 0x60,11,305,1 Thermal protector BSH
1 0x60,11,306,1 Clixon BUH
2 0x60,11,306,1 Thermal Protector BUH
16 0x60,11,306,1 Thermal protector (Q1L) BUH
1 0x60,11,307,1 Flow Switch
18 0x60,11,307,1 Water flow switch
1 0x60,12,300,1 Solar Output Signal
18 0x60,12,300,1 Solar pump operation
1 0x60,12,301,1 Pump Output
18 0x60,12,301,1 Water pump operation
9 0x60,12,302,1 BPH
1 0x60,12,302,1 Bottom Plate Heater
9 0x60,12,302,1 Floor loop shut off valve
18 0x60,12,303,1 BUH Step2
1 0x60,12,303,1 BUH2
18 0x60,12,304,1 BUH Step1
1 0x60,12,304,1 BUH1
19 0x60,12,305,1 BSH Booster Heater (DHW cylinder immersion heater)
18 0x60,12,306,1 3way valve(On:DHW_Off:Space)
1 0x60,12,306,1 4way Valve(Space/DHW)
18 0x60,12,307,1 2way valve(On:Heat_Off:Cool)
1 0x60,12,307,1 3way Valve(Cool/Heat)
18 0x60,13,152,1 Indoor Option Code
1 0x60,13,212,1 Indoor Option Code
18 0x60,14,215,1 I/U Software ID (yy)
1 0x60,14,314,2 Indoor Software Version
1 0x60,15,212,1 Indoor EEPROM Version
18 0x60,15,215,1 I/U Software ID (xx)
18 0x60,16,152,1 I/U EEPROM Ver.
19 0x60,2,300,1 Freeze Protection for water piping
19 0x60,2,301,1 Silent Mode
19 0x60,2,302,1 Freeze Protection
19 0x60,2,303,1 Thermostat ON/OFF This appears to be ANY thermostat: main or additional zone, DHW tank or room frost protection
18 0x60,2,315,1 I/U operation mode Tells you for what the compressor is running: DHW (default) or Heating or both Heating + DHW
1 0x60,2,315,1 Indoor Operation Mode
19 0x60,3,204,1 Error Code
11 0x60,4,152,1 Error detailed code Displays "0" in normal operation. As example, this will output "4" as part of the "7H-04" error for "water flow problem during domestic hot water production".
2 0x60,4,152,2 Indoor Unit Code
6 0x60,4,314,2 Indoor Unit Code
11 0x60,5,203,1 Error type
17 0x60,6,219,1 I/U capacity code
2 0x60,6,219,1 Indoor Unit Capacity
18 0x60,7,105,2, DHW setpoint
1 0x60,7,105,2, R/C Setpoint
1 0x60,9,105,2, H/P Outlet Setpoint
18 0x60,9,105,2, LW setpoint (main) target temperature from your water logic (function of the external temp)
19 0x61,0,307,1 Data Enable/Disable
19 0x61,1,152,1 Indoor Unit Address
18 0x61,10,105,2, DHW tank temp. (R5T)
1 0x61,10,105,2, DHW temperature(R5T) Water tank current temp
16 0x61,12,105,2, Indoor ambient temp. (R1T)
2 0x61,12,105,2, RT Temp.
1 0x61,12,105,2, Remocon thermistor
2 0x61,13,105,2, Ext. indoor ambient sensor (R6T)
13 0x61,14,105,2, Ext. indoor ambient sensor (R6T) This is indoor or outdoor remote/external temp sensor
2 0x61,14,105,2, Outdoor Ambient or Ext Sensor
15 0x61,2,105,2, Leaving water temp. before BUH (R1T) Outgoing Flow temperature - Caution: if your HP has a built-in BUH, this is NOT the actual LWT! Use R2T below
1 0x61,2,105,2, Outlet PHE(R1T)
3 0x61,2,105,2, Outlet Water Heat Exch. Temp. (R1T)
15 0x61,4,105,2, Leaving water temp. after BUH (R2T) If your HP has a built-in BUH, this is the sensor that provides correct LWT
1 0x61,4,105,2, Outlet BUH(R2T)
3 0x61,4,105,2, Outlet Water BUH Temp. (R2T)
1 0x61,6,105,2, Liquid temperature(R3T)
18 0x61,6,105,2, Refrig. Temp. liquid side (R3T)
1 0x61,8,105,2, Inlet temperature(R4T) Return flow temperature
18 0x61,8,105,2, Inlet water temp.(R4T)
18 0x62,0,307,1 Data Enable/Disable
18 0x62,1,152,1 Indoor Unit Address
18 0x62,11,105,1, Water pressure
18 0x62,12,152,1 Water pump signal (0:max-100:stop)
2 0x62,13,152,1 3 way Valve Mixing 1
16 0x62,13,152,1 [Future] 3 way Valve Mixing 1
2 0x62,14,152,1 3 way Valve Mixing 2
16 0x62,14,152,1 [Future] 3 way Valve Mixing 2
1 0x62,15,105,2, Pressure sensor
3 0x62,15,105,2, Refrigerant pressure sensor
10 0x62,15,152,1 Not in use
1 0x62,15,152,2 Not in use
3 0x62,15,152,2, Refrigerant pressure sensor
10 0x62,16,300,1 Not in use
10 0x62,16,301,1 Not in use
10 0x62,16,302,1 Not in use
10 0x62,16,303,1 Not in use
10 0x62,16,304,1 Not in use
10 0x62,16,305,1 Not in use
10 0x62,16,306,1 Not in use
10 0x62,16,307,1 Not in use
1 0x62,17,300,1 Not in use
1 0x62,17,301,1 Not in use
1 0x62,17,302,1 Not in use
1 0x62,17,303,1 Not in use
1 0x62,17,304,1 Not in use
1 0x62,17,305,1 Not in use
1 0x62,17,306,1 Not in use
1 0x62,17,307,1 Not in use
18 0x62,2,300,1 Emergency (indoor) active/not active
18 0x62,2,301,1 Not in use
18 0x62,2,302,1 System OFF (ON:System off)
18 0x62,2,303,1 Space heating Operation ON/OFF
18 0x62,2,304,1 Powerful DHW Operation. ON/OFF
18 0x62,2,305,1 Storage comfort ON/OFF
18 0x62,2,306,1 Storage eco ON/OFF
18 0x62,2,307,1 Reheat ON/OFF
18 0x62,3,105,2, LW setpoint (add) delta you can chose from the main setpoint (on my thermostat it goes from -5 to 5
18 0x62,5,105,2, RT setpoint The temperature you have set for your Central Heating
18 0x62,7,300,1 Pwr consumption limit 1
18 0x62,7,301,1 Pwr consumption limit 2
18 0x62,7,302,1 Pwr consumption limit 3
18 0x62,7,303,1 Pwr consumption limit 4
18 0x62,7,304,1 Main RT Heating
18 0x62,7,305,1 Main RT Cooling
18 0x62,7,306,1 Add. Ext. RT Input Heat.
18 0x62,7,307,1 Add. Ext. RT Input Cool.
2 0x62,8,300,1 Space C/H Op. or BPH
16 0x62,8,300,1 Space H Operation output
18 0x62,8,301,1 Alarm output
18 0x62,8,302,1 Circulation pump operation
2 0x62,8,303,1 Mode conflict
1 0x62,8,303,1 Not in use
15 0x62,8,303,1 Tank preheat ON/OFF
2 0x62,8,304,1 DHW priority request
10 0x62,8,304,1 Not in use
6 0x62,8,304,1 PHE Heater
16 0x62,8,305,1 Not in use
2 0x62,8,305,1 Powerful demand
2 0x62,8,306,1 Defrost prohibition ON/OFF
16 0x62,8,306,1 Not in use
18 0x62,8,307,1 None
18 0x62,9,105,2 Flow sensor (l/min)
18 0x63,0,307,1 Data Enable/Disable
18 0x63,1,152,1 Indoor Unit Address
2 0x63,10,215,1 Not in use
2 0x63,11,215,1 Not in use
2 0x63,12,215,1 Not in use
1 0x63,13,152,1 BUH output capacity
2 0x63,13,311,1 BUH output capacity
3 0x63,14,161,1 Current measured by CT sensor of L1
3 0x63,15,161,1 Current measured by CT sensor of L2
3 0x63,16,161,1 Current measured by CT sensor of L3
3 0x63,16,307,1 HP Forced FG
1 0x63,16,307,1 HP is operation forced OFF by installer
18 0x63,2,215,1 I/U EEPROM (3rd digit)
18 0x63,3,215,1 I/U EEPROM (4th 5th digit)
18 0x63,4,215,1 I/U EEPROM (6th 7th digit)
18 0x63,5,215,1 I/U EEPROM (8th 9th digit)
18 0x63,6,215,1 I/U EEPROM (11th digit)
16 0x63,7,214,1 I/U EEPROM (12th digit)(rev.)
2 0x63,7,215,1 I/U EEPROM (12th digit)(rev.)
2 0x63,8,215,1 Not in use
2 0x63,9,215,1 Not in use
17 0x64,0,307,1 Data Enable/Disable
17 0x64,1,152,1 Indoor Unit Address
7 0x64,10,105,2, Mixed water temp.
7 0x64,10,118,2, Mixed water temp.(R7T)
8 0x64,12,105,2, 2nd Domestic hot water temperature
1 0x64,14,152,1 Target delta T heating
7 0x64,14,152,1, Target delta T heating
1 0x64,15,152,1 Target delta T cooling
7 0x64,15,152,1, Target delta T cooling
3 0x64,2,300,1 Hybrid DHW operation mode
17 0x64,2,301,1 Bypass Valve Output
17 0x64,2,302,1 Boiler DHW Demand
17 0x64,2,303,1 Boiler Operation Demand
17 0x64,2,316,1 Hybrid Op. Mode
17 0x64,3,105,2 BE_COP
17 0x64,5,105,2, Hybrid Heating Target Temp.
17 0x64,7,105,2, Boiler Heating Target Temp.
2 0x64,9,300,1 Main pump
2 0x64,9,301,1 Add pump
12 0x64,9,301,1 Main pump
12 0x64,9,302,1 Add pump
2 0xA0,0,119,2, Suction temp
2 0xA0,10,152,1 O/U MPU ID
2 0xA0,11,152,1 O/U MPU ID
2 0xA0,12,300,1 52C Output
2 0xA0,12,301,1 4 way valve (Y1S)
1 0xA0,12,301,1, 4 way valve (Y1S)
2 0xA0,12,302,1 Solenoid Valve 1
1 0xA0,12,303,1 SV (drain pan heater)
1 0xA0,12,303,1 Solenoid Valve 2
2 0xA0,12,304,1 Solenoid Valve 3
2 0xA0,12,305,1 Crank case heater
2 0xA0,12,306,1 Safeguard operation
2 0xA0,12,307,1 HPS operation
2 0xA0,13,300,1 Powerful bit (MT setting bit)
2 0xA0,13,301,1 Indoor unit blowout 50 ° C flag
2 0xA0,13,302,1 During emergency operation
2 0xA0,13,303,1 Discharge Temp. Drop
2 0xA0,14,105,2, Compressor port temperature
2 0xA0,2,119,2, Outdoor heat exchanger temp.
2 0xA0,4,119,2, Liquid pipe temp.
2 0xA0,6,119,2, Pressure
2 0xA0,8,151,2 Expansion valve 3 (pls)
3 0xA1,0,119,2, Water heat exchanger inlet temp.
3 0xA1,2,119,2, Water heat exchanger outlet temp.
3 0xA1,4,300,1 PHE Heater
3 0xA1,4,301,1 Bottom Plate Heater
2 0xA1,4,302,1 Liquid INJ solenoid valve (Y4S)
2 0xA1,5,114,2, Target Discharge Temp.
2 0xA1,7,114,2, Target port temperature
2 0xA1,9,300,1 Alterma LT setting
2 0xA1,9,301,1 Hydro split setting
2 0xA1,9,302,1 GSHP setting
2 0xA1,9,303,1 MT setting
2 0xA1,9,304,1 Minichiller setting
2 0xA1,9,305,1 Monobloc setting