//Brink Renovent HR
Switch Brink_VentilationMode "Ventilation mode [%s]" <ventilationrec> (gBrink) {channel="mqtt:topic:mosquitto:2bab1fbfa2:ventilation_mode"}
Contact Brink_BypassStatus "Bypass status[%s]" <bypass1> (gBrink) {channel="mqtt:topic:mosquitto:2bab1fbfa2:bypass_status" }
Switch Brink_FaultIndication "Fault !" <error1> (gBrink,gAlarm) {channel="mqtt:topic:mosquitto:2bab1fbfa2:fault_indication"}
Number Brink_FaultCode "Fault code" <error> (gBrink) {channel="mqtt:topic:mosquitto:2bab1fbfa2:fault_code"}
Switch Brink_FilterCheck "Filter check [%s]" <airfilter1> (gBrink,gAlarm) {channel="mqtt:topic:mosquitto:2bab1fbfa2:filter_dirty"}
String Brink_BypassMessage "Bypass position change [%s]" <info> (gBrink) {channel="mqtt:topic:mosquitto:2bab1fbfa2:bypass_change"}
Number Brink_SupplyInletTemp "GHE => Brink [%.1f °C]" <temperature> (gBrink) {channel="mqtt:topic:mosquitto:2bab1fbfa2:temp_from_atmo"}
Number Brink_Ventiltion_Speed "Current vent. capacity [%d m³/h]" <ventilationcapacity1>(gBrink) {channel="mqtt:topic:mosquitto:2bab1fbfa2:curr_ventilation_volume"}
Number Brink_ExhaustInletTemp "Indoor => Brink [%.1f °C]" <temperature> (gBrink) {channel="mqtt:topic:mosquitto:2bab1fbfa2:temp_from_indoors"}
Number Brink_CPID "Current preassure input duct [%s Pa]" <pressure> (gBrink) {channel="mqtt:topic:mosquitto:2bab1fbfa2:curr_pressure_inpuct_duct"}
Number Brink_CPOD "Current preassure input duct [%s Pa]" <pressure> (gBrink) {channel="mqtt:topic:mosquitto:2bab1fbfa2:curr_pressure_output_duct"}
//Number Brink_ActualExhaustFanSpeed "ActualExhaustFanSpeed [%d rpm]"
//Number Brink_ActualInletFanSpeed "ActualInletFanSpeed [%d rpm]"
Number Brink_U1 "Low [%d m³/h]" <setu1> (gBrink) {channel="mqtt:topic:mosquitto:2bab1fbfa2:U1"}
Number Brink_U2 "Mid [%d m³/h]" <setu2> (gBrink) {channel="mqtt:topic:mosquitto:2bab1fbfa2:U2"}
Number Brink_U3 "High [%d m³/h]" <setu3> (gBrink) {channel="mqtt:topic:mosquitto:2bab1fbfa2:U3"}
Number Brink_U4 "Min outside temp [%d °C]" <setu4> (gBrink) {channel="mqtt:topic:mosquitto:2bab1fbfa2:U4"}
Number Brink_U5 "Min indoor temp [%d °C]" <setu5> (gBrink) {channel="mqtt:topic:mosquitto:2bab1fbfa2:U5"}
Dimmer Brink_VentilationSetpoint "Set relative ventilation [%d %%]" <ventilationset2> (gBrink,gRestore) {channel="mqtt:topic:mosquitto:2bab1fbfa2:ventilation_nominal_value"}
Number Brink_Wifi "RSSI [%d dBm]" <wifi1> (gBrink) {channel="mqtt:topic:mosquitto:2bab1fbfa2:wifi_signal"}
//Floor circulation pump option
Switch HWCP_Switch "Floor circulation" <switch> (gVaillant) {channel="mqtt:topic:mosquitto:2bab1fbfa2:hw_circulation_pump"}