Notifications
You must be signed in to change notification settings - Fork 3
/
Brink_HR.ino
320 lines (252 loc) · 9.61 KB
/
Brink_HR.ino
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
/* Openhab - Brink Renovent HR Integration
Author: Raf1000
December 2021
*/
#include <Arduino.h>
#include <OpenTherm.h>
#include <ESP8266WiFi.h>
#include <PubSubClient.h>
// this part schall be changed ----------------------------------
const char* ssid = "SET SSID of YOUR NETWORK";
const char* password = "PASSWORD";
const char* mqtt_server = "SET MQTT IP";
const char* mqtt_client_id = "brink"; // Unique client id
const int mqtt_Port = 1883;
const char* mqtt_User = "SET MQTT USER";
const char* mqtt_Password = "SET MQTT PASSWORD";
const float maxVent = 2.49; //it means 249 m/h3 - max avilable flow in my Brink - NOT USED
const unsigned long readPeriod = 1500; // OT protocol requires master to communicate at least every 1 sec (+15% tolerance).
// ---------------------------------------------------------------
const char* mqtt_topic_in = "brink/+/set"; //subscribe commands from Openhab
unsigned long startTime;
unsigned long currentTime;
const int HWCPin = 14; //Option: HW circulation pump D5
const int inPin = 4; //ESP8266 D2
const int outPin = 5; //ESP8266 D1
OpenTherm ot(inPin, outPin);
WiFiClient espClient;
PubSubClient mqttClient(espClient);
float tIn, tIn_old = 0; // temp external
float tOut, tOut_old = 0; //temp internal
bool fault, fault_old = 1;
bool vmode, vmode_old = 0;
bool sbypass, sbypass_old = 1;
//bool pbypass, pbypass_old;
bool filter, filter_old = 1;
int gvent, gvent_old = 0;
int pressin, pressin_old = 0;
int pressout, pressout_old = 0; // uint8_t
int vstep1, vstep1_old = 50;
int vstep2, vstep2_old = 150;
int vstep3, vstep3_old = 300;
int tU4, tU4_old = 1; //atmosphee temp U4
int tU5, tU5_old = 1; //inside temp U5
int cvol, cvol_old = 0;
int RPMin, RPMin_old;
int RPMout, RPMout_old;
int fcode, fcode_old = 0;
int msg, msg_old = 0;
int param1, param1_old = 100;
long lRssi, lRssi_old = 0;
void ICACHE_RAM_ATTR handleInterrupt() {
ot.handleInterrupt();
}
void MqttReconnect() {
while (!mqttClient.connected()) {
Serial.println("Connecting to MQTT Broker ");
Serial.println( mqtt_server );
delay(1000);
if (mqttClient.connect(mqtt_client_id,mqtt_User,mqtt_Password)) {
Serial.print("connected, topic: ");
mqttClient.subscribe(mqtt_topic_in);
Serial.println( mqtt_topic_in );
} else {
Serial.print("failed: ");
Serial.print(mqttClient.state());
Serial.println(" try again...");
delay(5000);
}
}
Serial.println(" ok...");
}
void MqttCallback(char* topic, byte* payload, unsigned int length) {
payload[length] = 0;
// Changing selected Brink Renovent HR parameters requested by OpenHab
if(strcmp(topic, "brink/VentNomValue/set") == 0) ot.setVentilation( atoi((char *)payload) ); // uint8_t
if(strcmp(topic, "brink/U4/set") == 0) ot.setBrinkTSP(U4, atoi((char *)payload)*2 );
if(strcmp(topic, "brink/U5/set") == 0) {
ot.setBrinkTSP(U5, atoi((char *)payload)*2 );
refreshAll(); // change of U5 triggers refresh of other paramteres
}
// HW Circulation pump swith - option
if(strcmp(topic, "brink/HWCP/set") == 0) {
if ( *payload == '1' ) digitalWrite(HWCPin, LOW); // realy switch on
if ( *payload == '0' ) digitalWrite(HWCPin, HIGH); // realy swich off
}
}
void setup()
{
Serial.begin(115200);
Serial.println("Start");
WiFi.mode(WIFI_STA);
WiFi.begin(ssid, password);
while (WiFi.status() != WL_CONNECTED)
{
Serial.print(".");
delay(500);
}
Serial.println("");
Serial.print("IP Addresss :");
Serial.print(WiFi.localIP());
mqttClient.setServer(mqtt_server, mqtt_Port);
mqttClient.setCallback(MqttCallback);
MqttReconnect();
startTime = millis();
ot.begin(handleInterrupt);
// Floor heting pump switch - option
pinMode(HWCPin, OUTPUT);
digitalWrite(HWCPin, HIGH);
}
// refresh slow changing parameters on request by every change of U5
void refreshAll()
{
mqttClient.publish("brink/TempSupplyIn/get", String(tIn).c_str());
mqttClient.publish("brink/TempExhIn/get", String(tOut).c_str());
mqttClient.publish("brink/FauiltIndication/get", String(fault).c_str());
mqttClient.publish("brink/VentilationMode/get", String(vmode).c_str());
mqttClient.publish("brink/BypassStaus/get", String(sbypass).c_str());
mqttClient.publish("brink/FilterDirty/get", String(filter).c_str());
mqttClient.publish("brink/VentilationNominalValue/get", String(gvent * 2.48).c_str());
mqttClient.publish("brink/CurrentVolume/get", String(cvol).c_str());
mqttClient.publish("brink/FaultCode/get", String(fcode).c_str());
mqttClient.publish("brink/OperationMsg/get", String(msg).c_str());
mqttClient.publish("brink/I1/get", String(param1 - 100).c_str());
mqttClient.publish("brink/U1/get", String(vstep1).c_str());
mqttClient.publish("brink/U2/get", String(vstep2).c_str());
mqttClient.publish("brink/U3/get", String(vstep3).c_str());
mqttClient.publish("brink/U4/get", String(tU4/2).c_str());
mqttClient.publish("brink/U5/get", String(tU5/2).c_str());
mqttClient.publish("brink/Wifi/get", String(lRssi).c_str());
mqttClient.publish("brink/OpenThermStatus/get", "WORK");
}
void loop()
{
if (!mqttClient.connected())
{
MqttReconnect();
mqttClient.publish("brink/OpenThermStatus/get", "WORK");
}
mqttClient.loop();
currentTime = millis();
if (currentTime - startTime >= readPeriod)
{
ReadBrinkParameters();
lRssi = WiFi.RSSI(); //long
if ( abs(lRssi- lRssi_old) > 2) { //reduce data publication due frequent slight changes of signal
mqttClient.publish("brink/Wifi/get", String(lRssi).c_str());
lRssi_old = lRssi;
}
startTime = currentTime;
}
}
//Reading selected Brink Renovent HR parameters, Mqtt publication only if a value has changed
void ReadBrinkParameters()
{
tIn = ot.getVentSupplyInTemperature();
if ( abs(tIn - tIn_old) > 0.2) { //reduce data publication due frequent slight changes of temp
mqttClient.publish("brink/TempSupplyIn/get", String(tIn).c_str());
tIn_old = tIn;
}
tOut = ot.getVentExhaustInTemperature();
if ( abs(tOut - tOut_old) > 0.2) { //reduce data publication due frequent slight changes of temp
mqttClient.publish("brink/TempExhIn/get", String(tOut).c_str()); // String.toCharArray()
tOut_old = tOut;
}
fault = ot.getFaultIndication();
if (fault != fault_old) {
mqttClient.publish("brink/FauiltIndication/get", String(fault).c_str());
fault_old = fault;
}
vmode = ot.getVentilationMode();
if (vmode != vmode_old) {
mqttClient.publish("brink/VentilationMode/get", String(vmode).c_str());
vmode_old = vmode;
}
sbypass = ot.getBrinkTSP(BypassStatus); // ot.getBypassStatus() - this method does not work
if (sbypass != sbypass_old) {
mqttClient.publish("brink/BypassStaus/get", String(sbypass).c_str());
sbypass_old = sbypass;
}
/* does not work
pbypass = ot.getBypassPosition();
if (pbypass != pbypass_old) {
mqttClient.publish("brink/BypassPosition/get", String(pbypass).c_str());
pbypass_old = pbypass;
}
*/
filter = ot.getDiagnosticIndication();
if (filter != filter_old) {
mqttClient.publish("brink/FilterDirty/get", String(filter).c_str());
filter_old = filter;
}
gvent = ot.getVentilation();
if (gvent != gvent_old) {
mqttClient.publish("brink/VentilationNominalValue/get", String(gvent * 2.49).c_str());
gvent_old = gvent;
}
pressin = ot.getBrinkTSP(CPID);
if ( abs(pressin - pressin_old) > 1 ) { //reduce data publication due frequent slight changes of preassure
mqttClient.publish("brink/CPID/get", String(pressin).c_str());
pressin_old = pressin;
}
pressout = ot.getBrinkTSP(CPOD);
if ( abs(pressout - pressout_old) > 1) { //reduce data publication due frequent slight changes of preassure
mqttClient.publish("brink/CPOD/get", String(pressout).c_str());
pressout_old = pressout;
}
cvol = ot.getBrinkTSP(CurrentVol);
if (cvol != cvol_old) {
mqttClient.publish("brink/CurrentVolume/get", String(cvol).c_str());
cvol_old = cvol;
}
fcode = ot.getVentFaultCode();
if (fcode != fcode_old) {
mqttClient.publish("brink/FaultCode/get", String(fcode).c_str());
fcode_old = fcode;
}
vstep1 = ot.getBrinkTSP(U1);
if (vstep1 != vstep1_old) {
mqttClient.publish("brink/U1/get", String(vstep1).c_str());
vstep1_old = vstep1;
}
vstep2 = ot.getBrinkTSP(U2);
if (vstep2 != vstep2_old) {
mqttClient.publish("brink/U2/get", String(vstep2).c_str());
vstep2_old = vstep2;
}
vstep3 = ot.getBrinkTSP(U3);
if (vstep3 != vstep3_old) {
mqttClient.publish("brink/U3/get", String(vstep3).c_str());
vstep3_old = vstep3;
}
tU4 = ot.getBrinkTSP(U4);
if (tU4 != tU4_old) {
mqttClient.publish("brink/U4/get", String(tU4/2).c_str());
tU4_old = tU4;
}
tU5 = ot.getBrinkTSP(U5);
if (tU5 != tU5_old) {
mqttClient.publish("brink/U5/get", String(tU5/2).c_str());
tU5_old = tU5;
}
msg = ot.getBrinkTSP(MsgOperation);
if (msg != msg_old) {
mqttClient.publish("brink/OperationMsg/get", String(msg).c_str());
msg_old = msg;
}
param1 = ot.getBrinkTSP(I1);
if (param1 != param1_old) {
mqttClient.publish("brink/I1/get", String(param1 - 100).c_str());
param1_old = param1;
}
}