when i set spiral vase mode and click on slice, the preview shows on the left some gcode, it shows the nozzle, but no part on the voron profile
if i use for example the mk3s profile, that works properly, without the gcode and the tool, but with a part ;-
)
This issue was already reported here #8032. It is already fixed on master. For now, it can be avoided by adding G1 Zxx to your start g-code (for example G1 Z0.2). I am closing this as a duplicate.
Description of the bug
when i set spiral vase mode and click on slice, the preview shows on the left some gcode, it shows the nozzle, but no part on the voron profile


if i use for example the mk3s profile, that works properly, without the gcode and the tool, but with a part ;-
)
Project file & How to reproduce
Form-Kubus.zip
Checklist of files included above
Version of PrusaSlicer
2.4.1 +win64
Operating system
Windows 10 21H2
Printer model
voron 2.4 with afterburner / MK3S (via octoprint)
The text was updated successfully, but these errors were encountered: