Indeed. Looks like the code for the board temp wasn't added for an unknown reason. Here's the PR #3749 that fixes this issue. |
Internal ticket number: BFW-5074 |
Fix merged :) Should got into the next release. |
Same here on 5.2.1. |
Well, it was mentioned in 5.2.1 announcement as fixed but indeed, code is not there. Someone did a mistake in announcement then. |
Indeed, I just checked and although the bugfix is mentioned in the v5.2.1 release notes, the PR isn't included in the commits @JohnnyDeer @CZDanol. |
Yep, it was supposed to go into 5.2.1. Sorry, guys, looks like administrative error. I've notified the team about that. |
Thanks @CZDanol |
Printer type - MK3.5
Printer firmware version - 5.2.0
Original or Custom firmware - Original
Describe the bug
Buddy board temperature is not shown.
How to reproduce
Go to "Sensor info" menu and notice there is "Not initialized" instead of board temperature.
Temperature is missing even after printer reset.
Expected behavior
Board temperature shown, just like on MK4 firmware.
The text was updated successfully, but these errors were encountered: