Restarting access-om2 requires outputNNN/ice/cice_in.nml #193
Comments
I should have said, this is with payu 0.11.2 |
Any idea if this has been fixed? It sounds like an older problem |
Did you mean this? #140 |
That's the one... I thought it had been fixed but guess not. Maybe @aidanheerdegen can confirm? |
Issue #140 is more about readability than this particular bug The code was changed some time ago to look for a https://github.com/payu-org/payu/blob/master/payu/models/cice.py#L194-L202 but it does look like there is no code to copy the updated |
Even if this is fixed at some point, it will remain an issue when starting from older restarts. |
Seems related: #88 and COSIMA/access-om2#43 |
Just to confirm that I accidentally discovered this has not been fixed, or else has re-emerged. Does anybody know how we fix this one? |
To start a new access-om2 experiment from an existing restart (say,
restart123
) it is necessary to copy/link bothrestart123
andoutput123/ice/cice_in.nml
to the new experiment'sarchive
, otherwise payu aborts withpayu: error: Cannot find prior namelist cice_in.nml
.It is counterintuitive to need more than just
restart123
.The text was updated successfully, but these errors were encountered: