Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathconfig.py
154 lines (128 loc) · 4.95 KB
/
config.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
# =============================================================================
# CONFIGURATION FILE
# =============================================================================
# Print extra information (optional) 0, 1 ,2 ,3. 3 means print everything
verbose = 3
clean = False # To clean temp files
Profile_flag = True # Use profiler
Fault_creator_flag = True # Use Fault generator
Fault_injector_flag = True # Use Fault injector
# To load exist config file
# Hazir bir config dosyasini eklemek icin en alttaki importu guncellestirin!!!
# =============================================================================
# Directory Configurations
# =============================================================================
# Directory of Binary File
directory = "./Samples/Polybench/GRAMSCHM/"
# Binary file
executable = "gramschmidt"
# Arguments, if not neccessary fill with blank string ""
args = ""
# Output results destination of Execution ****Required for SDC check***
output = "Output.txt"
# Fault injection Results output file
output_csv = "Fault_injection_results.csv"
# =============================================================================
# General Fault Injection Configurations
# =============================================================================
# number of fault
num_fault = 1000
breakKernelStart = "covariance.cu:159"
#breakConditional = "saxpy.cu:29 if i > 5"
breakConditional = ""
# maximum wait time
hang_factor = 20
# Fault injection memory type/ fault region
# reg, const, @global, @local, @shared, @generic
fault_reg = "reg"
# =============================================================================
# Specific Fault Injection Configurations
# =============================================================================
# In case of specific address space
min_address = "0x140"
max_address = "0x250" # address space interval
# In case of fault with specific block and thread
# Example: "1, 0, 0", otherwise ""
# Coordinates are consequently x y z
block_idx = ""
thread_idx = ""
# In case of fault with specific register,
# Example: register_id = "12" or left it blank
register_id = ""
# maximum register number
max_register = 64
# maximum bit number
max_bit = 32
breakNumber = 0
# =============================================================================
# Output Analysis (optional)
# =============================================================================
# if there is not saved output just determine the output info and location
use_output_line = False
# Output line, Output variable, Output length
output_info = "310, *G_outputFromGpu, 512*512"
output_name = "deneme.txt"
# =============================================================================
# Memory Analysis Configurations (optional)
# =============================================================================
use_memory_analysis = True
source_path = "covariance.cu" # optional
memory_output_path = "memory_out.txt" # output of the analysis
line_list_path = "linelist.txt" # saved memory lines
memory_watchlist = [["159","*E","512*512"], # 3rd kernel read E
["160","*F","512*512"], # 3rd kernel read F
["264","*G_outputFromGpu", "512*512"]] # after 3rd kernel read G
# =============================================================================
# Load Config File
# =============================================================================
use_load_config = True
config_path = "./config_files/bicg_cpe_test/"
if use_load_config:
import sys
try:
f = open("run_number.txt","r")
number = int(f.read())
f.close()
except:
number = 0
print("config 0")
sys.path.append(config_path)
if number == 1:
print("config 1")
from config1 import *
if number == 2:
print("config 2")
from config2 import *
if number == 3:
print("config 3")
from config3 import *
if number == 4:
print("config 4")
from config4 import *
# if number == 5:
# print("config 5")
# from config5 import *
# if number == 6:
# print("config 6")
# from config6 import *
# if number == 7:
# print("config 7")
# from config7 import *
# if number == 8:
# print("config 8")
# from config8 import *
# if number == 9:
# print("config 9")
# from config9 import *
# if number == 10:
# print("config 10")
# from config10 import *
# if number == 11:
# print("config 11")
# from config11 import *
# if number == 12:
# print("config 12")
# from config12 import *
# if number == 13:
# print("config 13")
# from config13 import *