[Bug] - Image of .Net auto-instrumentation can't be pulled #1059

Closed
avadhut123pisal opened this issue Aug 25, 2022 · 0 comments · Fixed by #1060
Closed

[Bug] - Image of .Net auto-instrumentation can't be pulled #1059

avadhut123pisal opened this issue Aug 25, 2022 · 0 comments · Fixed by #1060

Comments

@avadhut123pisal
Copy link
Contributor

  1. Operator image is using this ghcr.io/open-telemetry/opentelemetry-operator/autoinstrumentation-dotnet:0.0.0 as the default value for the .Net auto-instrumentation image.
  2. Publish image workflow for the Operator image is not setting the AUTO_INSTRUMENTATION_DOTNET_VERSION as a build argument for the Operator docker image, which caused the Operator to use 0.0.0 as a tag for the image.
  3. I have raised the PR to fix the same.
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment